scholarly journals Demand-controlled ventilation in new residential buildings: Consequences on indoor air quality and energy savings

2013 ◽  
Vol 24 (2) ◽  
pp. 162-173 ◽  
Author(s):  
Arefeh Hesaraki ◽  
Sture Holmberg
Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 250
Author(s):  
Chuloh Jung ◽  
Jihad Awad

Due to unprecedented urbanization, UAE had built many new residential projects with poor choices of material and ventilation. This social phenomenon is leading UAE to Sick Building Syndrome (SBS) faster than any other countries. The Dubai Municipality regulates the indoor air quality with strict stipulation, but the detailed regulations are still insufficient. The objective of this paper is to measure the indoor air quality of new residential projects in Dubai to suggest the improvement of the regulations for indoor air quality. As a methodology, a field survey was conducted to investigate the status of indoor air pollution in residential buildings. Based on the field survey data, lab experiments for building materials were conducted and a computer simulation on radon gas was conducted. The result had shown that radon gas was mainly detected in new townhouses and labor camp houses, and its concentration was found to exceed the standard. Volatile organic solvents (VOCs) and formaldehyde (CH2O) were mainly detected in showhouses and new townhouses, and the concentration distribution was about 10 times higher than that of outdoors. It was proven that emission concentration of radon gas from various building materials were detected, and the order was red clay, gypsum board, and concrete. Volatile organic solvents (VOCs) are mainly detected in oil paints and PVC floor and the radiation amount of all pollutants increased with temperature increase. In computer simulation, it was found that a new townhouse needs a grace period from 20 days to 6 months to lower the radon gas concentration by 2 pCi/L. This study will serve as a basic data to establish more detailed regulation for the building materials and improve the IAQ standards in Dubai.


2020 ◽  
pp. 1420326X2096076
Author(s):  
Pedro F. Pereira ◽  
Nuno M. M. Ramos

In Portugal, residential buildings commonly have their ventilation strategy changed after commissioning. This occurs due to the building managers' willingness to reduce shared costs with the electricity needed for fan operation. However, this option is not technically supported, and the effects of such a strategy on indoor air quality-related to human pollutants are yet to be quantified. CO2 was monitored in 15 bedrooms and air exchange rates were calculated for each room. The air exchange rate values ranged from 0.18 to 0.53 h−1 when mechanical extraction ventilation was off, and from 0.45 to 0.90 h−1 when mechanical extraction ventilation was on, which represents an average increase of 119%. With the current intermittent ventilation strategy, all rooms remain above 1500 ppm for a given percentage of time, and 12 rooms presenting CO2 concentrations above 2000 ppm. Simulations of theoretical CO2 concentrations, for a non-interrupted mechanical ventilation strategy show that no rooms would accumulate CO2 concentrations above 2000 ppm, and only 25% would present CO2 concentrations above 1500 ppm. Pearson correlations between the monitored CO2 and human and spatial factors identified two relevant parameters. Those parameters correspond to ratios between CO2 generation and floor area ([Formula: see text]), and airflow with CO2 generation ([Formula: see text]). The proposed ratios could be used as ways to optimise ventilation costs and indoor air quality.


2017 ◽  
Author(s):  
Behrang Chenari ◽  
Francisco Bispo Lamas ◽  
Adélio Rodrigues Gaspar ◽  
Manuel Gameiro da Silva

A significant amount of energy is being used by ventilation and air conditioning systems to maintain the indoor environmental condition in a satisfactory and comfortable level. Many buildings, either new or existing (throughout their renovation process) are subjected to energy efficiency requirements but these must not be in the expenses of indoor environmental conditions. For instance, indoor air quality (IAQ) has to be considered while improving energy efficiency, otherwise occupants might be exposed to inappropriate indoor environment.Demand-controlled ventilation (DCV) is a method that provides comfortable IAQ level with lowest energy use. In this paper, the main objective is developing a new CO2-based DCV strategy and simulating it using EnergyPlus. The IAQ and energy consumption associated to this strategy have been compared with the results of CO2-based DCV strategies previously developed by the same authors in another article. The comparison shows that the new strategy performs better, both in energy use and IAQ. The recorded energy savings ranged between 6-14% comparing with the previously developed strategies while IAQ slightly improved.