Transesophageal Echocardiographic Guidance of Thoracic Aortic Stent-Graft Implantation

2002 ◽  
Vol 9 (2_suppl) ◽  
pp. II-14-II-19 ◽  
Author(s):  
Wolfram Schütz ◽  
Albrecht Gauss ◽  
Rainer Meierhenrich ◽  
Reinhard Pamler ◽  
Johannes Görich

Purpose: To evaluate the efficacy of intraoperative transesophageal echocardiography (TEE) as an adjunctive measure in guiding the implantation of endoluminal stent-grafts in the thoracic aorta. Methods: TEE was used in 21 of 30 patients (27 men; median age 70 years; range 19–77) undergoing implantation of Excluder or Talent stent-grafts for management of 11 type B aortic dissections, 7 thoracic aortic aneurysms, 2 traumatic thoracic aortic ruptures, and an aortic coarctation. We evaluated the ability of TEE to provide evidence of (1) correct placement of the guidewire within the true lumen, (2) reduction in blood flow in the false lumen following stent deployment, and (3) early complications. Results: Definite identification of the true lumen and a reliable evaluation of the position of the stent-graft guidewire during advancement were possible in all patients. Reduction of blood flow within the false lumen following deployment of the stent-graft was visualized in >70% of patients with aortic dissection. In the patient with aortic coarctation, TEE recognized the acute onset of aortic dissection following stent dilation, which resulted in immediate management with an additional stent. Conclusions: The intraoperative use of TEE in the implantation of stent-grafts in the thoracic aorta is not significantly invasive and is easily employed. It permits excellent evaluation of the correct placement of the stent guidewire and, in patients with aortic dissection, intraoperatively visualizes effective blood flow reduction in the false lumen following stent-graft deployment. Its ability to recognize early complications may indicate the need for additional maneuvers during the surgical procedure.

2016 ◽  
Vol 24 (1) ◽  
pp. 107-111 ◽  
Author(s):  
Jiang Xiong ◽  
Yangyang Ge ◽  
Xiaoping Liu ◽  
Lijun Wang ◽  
Wei Guo

Purpose: To describe the use and 6-month outcomes of the octopus endograft technique to reconstruct renovisceral arteries arising from the false lumen (FL) of a type B aortic dissection after thoracic endovascular aortic repair (TEVAR). Case Report: A 46-year-old man post TEVAR for type B aortic dissection was admitted with persistent back pain and a rapidly expanding residual dissection. The celiac and left renal arteries arose from the FL and the superior mesenteric artery from both lumens, with the FL as its main supply. A 20% oversized Endurant stent-graft was deployed with the short limb just above the beginning of the dissection flap and the long limb in the aortic true lumen. A 120-mm-long Endurant extended limb was delivered antegradely via a conduit and deployed into the FL, with a 3-cm overlap with the short limb of the Endurant main body. The 3 renovisceral arteries were reconstructed by lining each with a series of Viabahn or Fluency stent-grafts whose proximal ends were subsequently placed parallel in the FL Endurant extended limb and dilated with kissing balloons. Imaging at 6 months showed an excluded FL, without stenosis or occlusion in the stent-graft or the renovisceral arteries. Conclusion: This case illustrates the successful use of the octopus endograft technique to reconstruct renovisceral arteries arising from a rapidly expanding FL in a post-TEVAR type B aortic dissection; the technique might be applicable in carefully selected patients.


Circulation ◽  
2000 ◽  
Vol 102 (suppl_3) ◽  
Author(s):  
Hiromu Terai ◽  
Nobushige Tamura ◽  
Tatsuo Nakamura ◽  
Kazunobu Nishimura ◽  
Norimasa Tsutsui ◽  
...  

Background —Despite recent progress in medical and surgical treatment, acute type B aortic dissection still carries a high mortality rate. We have developed a novel cylindrical balloon catheter for less invasive treatment to block the entry of the dissection and induce thrombotic occlusion of the false lumen. The balloon has the shape of a sheet when deflated but a double-cylinder shape when inflated. Therefore, aortic blood flow is maintained through the cylindrical lumen during balloon inflation. Methods and Results —Six beagle dogs underwent a left thoracotomy at the 6th intercostal space. An acute dissection of 4-cm length was created surgically on the descending aorta. The balloon catheter was inserted through the distal descending aorta and advanced to the entry site. The balloon catheter was inflated for 6 hours. The blood flow in the descending aorta and the position of the balloon was monitored by color Doppler echovasculography. Four dogs were killed humanely on the following day and 2 dogs 10 days after the surgery. The descending aorta was examined macroscopically and microscopically in all dogs. In all dogs, the false lumen was occluded by thrombi. Although no dog had clinical evidence of distal thromboembolism, 2 of the 4 dogs that were killed on the second postoperative day had fresh mural thrombi in the true lumen. Conclusions —The false lumen of the acute type B aortic dissection was effectively occluded by the novel cylindrical balloon catheter in the canine experimental model. The thrombus formation in the true lumen is the problem to be solved.


Author(s):  
Koichi Tamai ◽  
Daijiro Hori ◽  
Koichi Yuri ◽  
Atsushi Yamaguchi

Abstract Using a frozen elephant trunk (FET) in patients with acute aortic dissection is an effective method to induce aortic remodelling after surgery. A 40-year-old man with Stanford type A acute aortic dissection underwent emergency total arch replacement with FET. The FET was inserted into the descending aorta under direct vision. However, transoesophageal echocardiography after the deployment of the FET revealed that it was misdeployed in the false lumen. An additional FET was deployed in the true lumen to redirect the blood flow to the true lumen. The patient was discharged from the hospital without any major complications. Computed tomography 6 months after surgery revealed enhanced aortic remodelling without any signs of stent graft-induced new entry. Additional deployment of a FET into the true lumen could be an option for a misdeployed FET in the false lumen.


2002 ◽  
Vol 9 (6) ◽  
pp. 817-821 ◽  
Author(s):  
Won-Heum Shim ◽  
Bon-Kwon Koo ◽  
Young-Sup Yoon ◽  
Donghoon Choi ◽  
Yangsoo Jang ◽  
...  

Purpose: To evaluate the early and midterm outcomes after stent-graft implantation for dissection in the descending thoracic aorta. Methods: Sixteen custom-made endovascular stent-grafts were implanted in 15 patients (10 men; mean age 55.9 ± 13.7 years, range 32–82) with descending thoracic aortic dissection. Indications for stent-graft implantation were persistent symptoms unresponsive to medical treatment or progressive enlargement of the false lumen. Clinical and imaging surveillance with computed tomography was performed within 1 month of the procedure and at 3 to 6-month intervals in follow-up. Results: Endovascular stent-graft implantation at the target site was successful in 14 (93%) patients; 1 device migrated, leaving the false lumen open to flow in the failed case. One (7%) patient who was treated emergently for rupture died suddenly 2 days after the procedure. Over an average follow-up of 31.5 ± 23.8 months, 1 (7%) patient died and 2 (14%) patients underwent surgical treatment due to recurrent dissection. The remaining 10 patients showed complete thrombosis of the false lumen; in 3, the false lumen completely resolved. Conclusions: Endovascular stent-graft implantation in descending thoracic aortic dissection is a feasible, safe, and effective treatment modality. However, further studies are necessary in a greater number of patients to determine if wider application of this minimally invasive procedure is justified.


Author(s):  
Mariafrancesca Fiorentino ◽  
Hector W L de Beaufort ◽  
Uday Sonker ◽  
Robin H Heijmen

Abstract OBJECTIVES The frozen elephant trunk technique is an increasingly common treatment for extensive disease of the thoracic aorta. The objective of the study was to evaluate the outcomes of frozen elephant trunk specifically in chronic (residual) aortic dissections, focusing on downstream aortic remodelling. METHODS Between 2013 and 2019, a total of 28 patients were treated using the Vascutek Thoraflex hybrid graft at our institution for chronic dissections/post-dissection aneurysms. Immediate and follow-up outcomes were studied, as well as the changes in total aortic diameter, true lumen and false lumen diameter and the status of the false lumen at 3 different levels of the thoraco-abdominal aorta. RESULTS No in-hospital or 30-day mortality was observed, temporary paraparesis rate was 7% and disabling stroke incidence was 14.3%. Freedom from all-cause mortality at 2 years was 91.6 ± 5.7%, while freedom from reintervention on the downstream aorta at 2 years was 59.1 ± 10.8%. Positive aortic remodelling was achieved in 50.0%, with an enlargement in the true lumen and a reduction of the false lumen not only at the level of the proximal descending aorta with 73.1% of complete thrombosis but also at the level of the distal descending thoracic aorta, with 41.7% of complete thrombosis. CONCLUSIONS The frozen elephant trunk is a good solution in chronic (residual) downstream aortic dissections inducing positive aortic remodelling and preventing from II stage operations or allowing an endovascular approach.


2016 ◽  
Vol 24 (1) ◽  
pp. 75-80 ◽  
Author(s):  
Tilo Kölbel ◽  
Christian Detter ◽  
Sebastian W. Carpenter ◽  
Fiona Rohlffs ◽  
Yskert von Kodolitsch ◽  
...  

Purpose: To describe the combined use of a tubular stent-graft for the ascending aorta and an inner-branched arch stent-graft for patients with acute type A aortic dissection. Technique: The technique to deploy these modular, custom-made stent-grafts is demonstrated in 2 patients with acute DeBakey type I aortic dissections and significant comorbidities precluding open surgery. Both emergent procedures were made possible by the availability of suitable devices manufactured for elective repair in other patients. After preliminary carotid-subclavian bypass, a long Lunderquist guidewire was introduced from the right femoral artery to the left ventricle for delivery of the Zenith Ascend and Zenith Branched Arch Endovascular Grafts under inflow occlusion. Bridging stent-grafts were delivered to the innominate and left common carotid arteries to connect to the 2 inner branches; the left subclavian artery was occluded. Both cases were technically successful and resulted in exclusion of the false lumen in the ascending aorta. The operating and fluoroscopy times did not exceed those of comparable elective procedures. The patients were rapidly extubated shortly after the procedure and without serious immediate complications. One patient survived 11 months with a satisfactory repair; the other succumbed to complications of recurrent pneumonia after 23 days. Conclusion: Endovascular treatment of patients with acute type A aortic dissection using a combination of tubular and branched stent-grafts in the ascending aorta is feasible and offers an alternative strategy to open surgery.


2002 ◽  
Vol 9 (2_suppl) ◽  
pp. II-92-II-97 ◽  
Author(s):  
Rodney A. White ◽  
Carlos Donayre ◽  
Irwin Walot ◽  
James Lee ◽  
George E. Kopchok

Purpose: To describe the successful endovascular repair and regression of an extensive descending thoracoabdominal aortic dissection associated with thoracic and abdominal aortic aneurysms. Case Report: An 83-year-old man presented with acute chest pain and shortness of breath. A descending thoracoabdominal aortic dissection that extended from near the left subclavian artery (LSA) to the right common iliac artery was found on computed tomography. Separate aneurysms in the thoracic and abdominal aorta were also identified. Staged endovascular procedures were undertaken to (1) close the single entry site and exclude the aneurysm in the thoracic aorta with an AneuRx thoracic stent-graft, (2) exclude the abdominal aneurysm and distal re-entry site with a bifurcated AneuRx endograft, and (3) treat a newly dilated thoracic segment between the LSA and first thoracic stent-graft. At 1 year, the false lumen had completely disappeared, the thoracic aneurysm had collapsed onto the endograft, and the abdominal aneurysm had shrunk by 30%. Conclusions: The potential to treat extensive aortic dissections with the hope that they might regress is promising, but repair of highly complex lesions involving one or more aneurysms in addition to the dissection requires meticulous imaging studies both preoperatively and intraprocedurally.


2003 ◽  
Vol 10 (2) ◽  
pp. 244-248 ◽  
Author(s):  
Maartje C. Loubert ◽  
Victor P.M. van der Hulst ◽  
Cees De Vries ◽  
Kees Bloemendaal ◽  
Anco C. Vahl

Purpose: To report techniques for excluding the dilated false lumen associated with chronic type B aortic dissection following placement of a stent-graft in the true lumen. Case Reports: Two patients underwent stent-graft implantation for a dilated false lumen after chronic aortic dissection, but the false lumen was not excluded from the circulation by this procedure. The false lumen was obliterated in one case with Greenfield filters and detachable balloons placed above a renal artery orifice that was perfused via the false lumen. This acted like “a cork in the bottleneck” to block retrograde flow into the thoracic portion of the false lumen above the blockade. In the other patient, an occluder device was used as the “cork.” In both cases, a good result was obtained. The occluder device is preferred because deployment is more controllable. Conclusions: An occluder device may be used like a cork in a bottle to exclude the dilated false lumen in the thoracic aorta after a type B dissection.


2020 ◽  
pp. 152660282096699
Author(s):  
Yaowang Lin ◽  
Shaohong Dong ◽  
Jianfan Luo ◽  
Weijie Bei ◽  
Qiyun Liu ◽  
...  

Purpose To compare the clinical outcomes after thoracic endovascular aortic repair (TEVAR) with a bare stent to those after TEVAR alone in patients with complicated acute type B aortic dissection (cATBAD). Materials and Methods A prospective, randomized trial was conducted at 2 medical centers in China between 2010 and 2013. Patients with cATBAD were randomly assigned to receive TEVAR with a bare stent (n=42) or TEVAR only (n=42). Patients were scheduled to undergo computed tomography angiography at 3, 6, and 12 months and then annually to 5 years. The primary endpoint was all-cause mortality at 5 years; secondary outcomes were a composite of complications (endoleak, stent-graft–induced new entry, aortic rupture, and secondary intervention) and aortic remodeling at 1 and 5 years. Results All-cause death occurred in 1 (2.4%) patient in the TEVAR with bare stent group (lung cancer) and 5 patients (11.9%) in the TEVAR group (4 aorta-related) during the 5-year follow-up (log-rank p=0.025). The 1- and 5-year rates of complications and secondary interventions did not differ between the groups. Patients in the TEVAR with bare stent group had higher increases in the thoracic true lumen diameter (19.7±3.6 vs 17.0±6.2 mm, p=0.018) and abdominal true lumen diameter (13.7±4.8 vs 7.2±6.1 mm, p<0.001) and a higher incidence of complete false lumen thrombosis (80.9% vs 47.6%, p=0.005) at the 1-year follow-up. However, no between-group differences in the changes of aortic remodeling parameters were observed between the 1- and 5-year follow-up periods. Conclusion The addition of a distal bare stent to a thoracic stent-graft during TEVAR was associated with significantly improved long-term survival in cATBAD patients vs TEVAR only, likely due to the prevention of true lumen collapse and improvement of complete false lumen thrombosis of the dissected aorta.


Sign in / Sign up

Export Citation Format

Share Document