scholarly journals Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

2018 ◽  
Vol 25 (4) ◽  
pp. 480-491 ◽  
Author(s):  
Maaike A. Koenrades ◽  
Almar Klein ◽  
Anne M. Leferink ◽  
Cornelis H. Slump ◽  
Robert H. Geelkerken

Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17–47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. Results: At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). Conclusion: Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.

2019 ◽  
Vol 53 (6) ◽  
pp. 515-519
Author(s):  
Toshiya Nishibe ◽  
Toru Iwahashi ◽  
Kentaro Kamiya ◽  
Masaki Kano ◽  
Keita Maruno ◽  
...  

We present 3 cases of type IIIb endoleak after endovascular aneurysm repair (EVAR) using the Zenith stent graft system. Type III endoleak, like type I endoleak, is a high-pressure, high-risk leak that increases sac pressure up to or even above arterial pressure, and is associated with an increased frequency of open conversions or risk of aneurysm rupture. Type IIIb endoleak is rare but there is much concern that the incidence of type IIIb endoleak is likely to increase hereafter; the mechanism of type IIIb endoleak is deterioration of graft fabric in conjunction with stent sutures. Type IIIb endoleak is difficult to diagnose before rupture. The possibility of type IIIb endoleak should be highly suspected when the continued growth of an excluded aneurysm sac without direct radiologic evidence is observed during follow-up. Type IIIb endoleak can be repaired by relining of the stent graft with additional stent grafts.


Vascular ◽  
2019 ◽  
Vol 28 (1) ◽  
pp. 48-52
Author(s):  
Allan Marc Conway ◽  
Khalil Qato ◽  
Gautam Anand ◽  
Laurie Mondry ◽  
Gary Giangola ◽  
...  

Objectives Marfan syndrome patients are at risk for aortic degeneration. Repair is traditionally performed with open surgery as this is deemed more durable. Endovascular aneurysm repair remains controversial. We report on the outcomes of Marfan syndrome patients with abdominal aortic aneurysms undergoing endovascular aneurysm repair. Methods The Vascular Quality Initiative registry identified 35,889 patients, including 29 with Marfan syndrome, treated with endovascular aneurysm repair from January 2003 to December 2017. Outcomes were analyzed per the Society for Vascular Surgery reporting standards. Results Median age was 70.0 years (IQR, 57.0–75.0), and 22 (75.9%) were male. Median aneurysm diameter was 5.3 cm (IQR, 4.9–6.3 cm), with an aortic neck length and diameter of 2.0 cm (IQR, 1.6–2.8 cm) and 2.5 cm (IQR, 2.2–2.8 cm), respectively. Twenty-one (72.4%) patients were asymptomatic, seven (24.1%) symptomatic, and one (3.4%) presented with rupture. Ten (34.5%) patients had prior aortic surgery. Six (20.7%) were unfit for open surgical repair. Length of stay was 2.0 days (IQR, 1.0–3.0 days). Percutaneous femoral access was performed in 15 (51.7%) patients with no complications. A type IA endoleak was present in one (3.4%), type IB in one (3.4%), and type II endoleak in two (6.9%) patients. There were no postoperative pulmonary, cardiac, or neurological complications. In-hospital mortality occurred in one (3.4%) patient who presented with a rupture and had been deemed unfit for open repair. A conversion to open repair was required. The patient expired on post-operative day 0. Early clinical success was achieved in 26 (89.7%) patients. Follow-up was available for 15 (51.7%) patients at a median time of 766 days (IQR, 653–937). There were no reinterventions or mortalities. Change in sac diameter was −0.6 cm (IQR, −1.1 to −0.2 cm), with no type I or III endoleaks. Discussion Endovascular aneurysm repair for patients with Marfan syndrome is feasible, and can be performed safely. Mid-term outcomes suggest this technique is durable. More robust long-term follow-up is needed.


Vascular ◽  
2008 ◽  
Vol 16 (5) ◽  
pp. 253-257 ◽  
Author(s):  
Evert J. Waasdorp ◽  
Joost A. van Herwaarden ◽  
Rob H.W. van de Mortel ◽  
Frans L. Moll ◽  
Jean-Paul P.M. de Vries

This study evaluated the value of computed tomographic angiography (CTA) early after an endovascular aneurysm repair (EVAR) in relation to CTA 3 months after EVAR. We retrospectively reviewed all elective EVAR patients with available postprocedural and 3-month follow-up CTAs who were treated between 1996 and 2006. CTAs were analyzed for EVAR-related complications in terms of endoleaks, migration, and stent graft thrombosis. Secondary procedures and other complications within a 4-month time interval after EVAR were noted and analyzed for any association with the postprocedural CTA. During the study period, 291 patients (275 men), with a mean age of 71 years, underwent elective EVAR. All had postprocedural and 3-month follow-up CTAs, which detected 93 (32%) endoleaks (8 type I, 84 type II, 1 type III) and 1 stent graft thrombosis. These findings resulted in four secondary interventions (one interposition cuff, two extension cuffs, one conversion). All reinterventions were successfully done in an elective setting. During the first 3 postoperative months, five other reinterventions were required for acute ischemia in four patients (three Fogarty procedures, one femorofemoral crossover bypass) or groin infection in one patient. Eight patients died, but none of the deaths were related to abdominal aortic aneurysm or EVAR (four cardiac, two pulmonary, one gastric bleeding, one carcinoma). At 3 months, 43 endoleaks (3 type I, 40 type II), 3 stent graft thromboses, and 1 stent graft migration were seen. In two patients (0.7%), a new endoleak was diagnosed compared with the postprocedural CTAs. In 287 (99%) of 291 patients, the postprocedural CTA did not influence our treatment policy in the first 3 months after EVAR. More than half of the early endoleaks were self-limiting, and new endoleaks were seen in only two patients (< 1%) at the 3-month follow-up CTA. After an uneventful EVAR procedure, it is safe to leave out the early postprocedural CTA.


Vascular ◽  
2017 ◽  
Vol 26 (3) ◽  
pp. 278-284 ◽  
Author(s):  
VP Bastiaenen ◽  
MGJ Snoeijs ◽  
JGAM Blomjous ◽  
J Bosma ◽  
VJ Leijdekkers ◽  
...  

Objectives Stent grafts for endovascular repair of infrarenal aneurysms are commercially available for aortic necks up to 32 mm in diameter. The aim of this study was to evaluate the feasibility of endovascular repair with large thoracic stent grafts in the infrarenal position to obtain adequate proximal seal in wider necks. Methods All patients who underwent endovascular aneurysm repair using thoracic stent grafts with diameters greater than 36 mm between 2012 and 2016 were included. Follow-up consisted of CT angiography after six weeks and annual duplex thereafter. Results Eleven patients with wide infrarenal aortic necks received endovascular repair with thoracic stent grafts. The median diameter of the aneurysms was 60 mm (range 52–78 mm) and the median aortic neck diameter was 37 mm (range 28–43 mm). Thoracic stent grafts were oversized by a median of 14% (range 2–43%). On completion angiography, one type I and two type II endoleaks were observed but did not require reintervention. One patient experienced graft migration with aneurysm sac expansion and needed conversion to open repair. Median follow-up time was 14 months (range 2–53 months), during which three patients died, including one aneurysm-related death. Conclusions Endovascular repair using thoracic stent grafts for patients with wide aortic necks is feasible. In these patients, the technique may be a reasonable alternative to complex endovascular repair with fenestrated, branched, or chimney grafts. However, more experience and longer follow-up are required to determine its position within the endovascular armamentarium.


2020 ◽  
Vol 27 (3) ◽  
pp. 462-467
Author(s):  
Konstantinos Tigkiropoulos ◽  
Kyriakos Stavridis ◽  
Ioannis Lazaridis ◽  
Evangelos Bontinis ◽  
Ioulia Zournatzi ◽  
...  

Purpose: To report outcomes of elective endovascular aneurysm repair (EVAR) using the Anaconda stent-graft in a tertiary vascular center. Materials and Methods: A retrospective study was conducted of 271 patients (mean age 71.5 years; 260 men) who underwent elective EVAR for abdominal aortic aneurysm using the Anaconda stent-graft from January 2006 to January 2017. Median aneurysm diameter was 58 mm (range 50–90). All patients were anatomically suitable for EVAR according to the 2003 version of the instructions for use. Follow-up included computed tomography angiography at 1, 6, and 12 months and yearly thereafter for the first 4 years and then every 2 years. Primary outcomes included technical success and 30-day aneurysm-related mortality and complications; secondary outcomes were overall and aneurysm-related mortality and aneurysm-related morbidity in follow-up. Results: The Anaconda stent-graft was implanted successfully in all patients. Primary and secondary technical success rates were 99.6% and 100%, respectively. Three patients (1.1%) died within 30 days of causes unrelated to the aneurysm, while 15 patients (5.5%) suffered perioperative complications. Median follow-up was 72 months (range 14–141). The overall type I endoleak rate was 4.7% (11 proximal, 2 distal). Late aneurysm-related complications were observed in 48 patients (17.3%); aneurysm-related mortality was 1.4% (n=4). Non-aneurysm-related mortality was 21.0% (n=57). Freedom from reintervention was 95.2% at 1 year, 98% at 2 years, and 90% at 6 years. There was no significant difference in the overall limb graft occlusion rate between the second- and third-generation devices. Conclusion: Results in our cohort study demonstrate that the Anaconda stent-graft has satisfactory early and late results with low aneurysm-related mortality.


2018 ◽  
Vol 25 (6) ◽  
pp. 726-734 ◽  
Author(s):  
Raman Uberoi ◽  
Carlo Setacci ◽  
Mario Lescan ◽  
Antonio Lorido ◽  
David Murray ◽  
...  

Purpose: To evaluate the safety and performance of the Treovance stent-graft. Methods: The global, multicenter RATIONALE registry ( ClinicalTrials.gov; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. Results: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. Conclusion: The RATIONALE registry showed favorable safety and clinical performance of the Treovance stent-graft for the treatment of infrarenal AAAs in a real-world setting.


2019 ◽  
Vol 53 (6) ◽  
pp. 458-463
Author(s):  
Rosa Marie Andersen ◽  
Benjamin S. B. Rasmussen ◽  
Ulrich Halekoh ◽  
Sten Langfeldt ◽  
Hossein Mohit Mafi ◽  
...  

Background: Few long-time follow-up studies describe all complications, treatment outcome of complications, and mortality in relation to endovascular aneurysm repair (EVAR). The purpose of this study was to evaluate the incidence and treatment outcome including mortality of radiological visible complications related to the EVAR procedure at a single center with up to 10 years’ surveillance. Materials and Methods: Patients treated with EVAR from March 2006 to March 2016 at a Danish university hospital, 421 in total, were included. Patient and aneurysm characteristics, follow-up, and secondary intervention data were collected from a national database and medical records. Follow-up computed tomography angiography and plain abdominal X-ray reports were reviewed for complications. Scans and X-rays with suspected complications were evaluated by an interventional radiologist. Results: A total of 172 complications in 147 patients, mainly in the beginning of the follow-up period, were found; 35% had a least one complication. The main part of complications (62%) was type II endoleaks, followed by stent graft stenosis (11%), type I endoleaks (9%), and stent graft occlusion (7%). A total of 66 (38%) complications, observed in 55 patients, were treated with reintervention, of which 77% were treated with endovascular procedures and 23% with surgical treatment, that is, 13% of all studied patients had a complication that required a reintervention. The remaining 2 of the 3 complications were treated conservatively. We found no increased all-cause mortality in connection with having a complication including those requiring reintervention. Conclusion: We presented a 10-year single-center study of EVAR. Many patients treated with EVAR had a radiological visible complication, mainly in the beginning of the follow-up period. Only a smaller fraction required reintervention and having a reintervention-requiring complication was not connected to increased mortality.


2016 ◽  
Vol 24 (2) ◽  
pp. 239-245 ◽  
Author(s):  
Hidde Jongsma ◽  
Joost A. Bekken ◽  
Wouter J. J. Bekkers ◽  
Clark J. Zeebregts ◽  
Joost van Herwaarden ◽  
...  

Purpose: To evaluate the efficacy, feasibility, and long-term outcomes of the Zenith ZBIS iliac branch device (IBD) to preserve internal iliac artery (IIA) perfusion in a large Dutch multicenter cohort. Methods: Between September 2004 and August 2015, 140 patients (mean age 70.9±7.4 years; 130 men) with 162 IBD implantations were identified in 7 vascular centers. The indication for IBD implantation was an abdominal aortic aneurysm >55 mm with a concomitant common iliac artery (CIA) aneurysm >20 mm (n=40), a CIA aneurysm with a diameter >30 mm (n=89), or revision of a type Ib endoleak after endovascular aneurysm repair (n=11). Results: Technical success (aneurysm exclusion, no type I or III endoleak, and a patent IIA) was obtained in 157 (96.9%) of 162 IBD implantations. Six (4.3%) patients developed major complications; 2 (1.4%) died. Mean follow-up was 26.6±24.1 months, during which 17 (12.1%) IBD-associated secondary interventions were performed. Including technical failures and intentional IIA embolizations, 15 (9.3%) IIA branch occlusions were identified; buttock claudication developed in 6 of these patients. The freedom from secondary intervention estimate was 75.9% (95% confidence interval 59.7 to 86.3) at 5 years. Conclusion: CIA aneurysms can be treated safely and effectively by IBDs with preservation of antegrade flow to the IIA. Secondary interventions are indicated in >10% of patients during follow-up but can be performed endovascularly in most.


2020 ◽  
Vol 4 ◽  
pp. 9
Author(s):  
Salman Mirza ◽  
Shahnawaz Ansari

We present a case of a 72-year-old male with an abdominal aortic aneurysm status post-endovascular aneurysm repair (EVAR). Follow-up imaging demonstrated an enlarging type II endoleak and attempts at transarterial coil embolization of the inferior mesenteric artery were unsuccessful. The patient underwent image-guided percutaneous translumbar type II endoleak repair using XperGuide (Philips, Andover, MA USA).


2018 ◽  
Vol 26 (1) ◽  
pp. 72-75
Author(s):  
Fabien Lareyre ◽  
Claude Mialhe ◽  
Carine Dommerc ◽  
Juliette Raffort

Purpose: To report the use of the Nellix endovascular aneurysm sealing (EVAS) system in the management of proximal stent-graft collapse associated with thrombosis following endovascular aneurysm repair (EVAR). Case Report: A 76-year-old man was admitted for proximal collapse of an aortic extension following bifurcated AFX stent-graft implantation associated with chimney grafts in both renal arteries and the superior mesenteric artery 1 month prior. Imaging identified thrombosis of the aortic stent-graft and the iliac limbs. A Nellix EVAS was placed into the AFX stent-graft to recanalize the aneurysm lumen and address the aortic thrombosis. There was no endoleak, and the renovisceral chimney stent-grafts remained patent over a follow-up of 25 months. Conclusion: While further studies are required to generalize its use, EVAS appears to be feasible in the management of aortic stent-graft collapse.


Sign in / Sign up

Export Citation Format

Share Document