scholarly journals An Analysis of the Assessment of Glycated Hemoglobin Using A1cNow+™ Point-of-Care Device Compared to Central Laboratory Testing—an Important Addition to Pharmacist-Managed Diabetes Programs?

2008 ◽  
Vol 2 (5) ◽  
pp. 828-830 ◽  
Author(s):  
Alan W. Carter
2008 ◽  
Vol 2 (5) ◽  
pp. 822-828 ◽  
Author(s):  
Justin R. Arrendale ◽  
Sonia E. Cherian ◽  
Issam Zineh ◽  
Mark J. Chirico ◽  
James R. Taylor

2018 ◽  
Vol 26 (4) ◽  
pp. 218-224 ◽  
Author(s):  
Jung Hee Han ◽  
Seongsoo Jang ◽  
Mi-Ok Choi ◽  
Mi-Jeong Yoon ◽  
Seung-Bok Lim ◽  
...  

Background: The confirmation of prothrombin time international normalized ratio by a central laboratory often delays intravenous thrombolysis in patients with acute ischemic stroke. Objectives: We investigated the feasibility, reliability, and usefulness of point-of-care determination of prothrombin time international normalized ratio for stroke thrombolysis. Methods: Among 312 patients with ischemic stroke, 202 who arrived at the emergency room within 4.5 h of stroke onset were enrolled in the study. Patients with lost orders for point-of-care testing for the prothrombin time international normalized ratio or central laboratory testing for the prothrombin time international normalized ratio (n = 47) were excluded. We compared international normalized ratio values and the time interval from arrival to the report of test results (door-to-international normalized ratio time) between point-of-care testing for the prothrombin time international normalized ratio and central laboratory testing for the prothrombin time international normalized ratio. In patients who underwent thrombolysis, we compared the time interval from arrival to thrombolysis (door-to-needle time) between the current study population and historic cohort at our center. Results: In the 155 patients included in the study, the median door-to-international normalized ratio time was 9.0 min (interquartile range, 5.0–12.0 min) for point-of-care testing for the prothrombin time international normalized ratio and 46.0 min (interquartile range, 38.0–55.0 min) for central laboratory testing for the prothrombin time international normalized ratio (p < 0.001). The intraclass correlation coefficient between point-of-care testing for the prothrombin time international normalized ratio and central laboratory testing for the prothrombin time international normalized ratio was 0.975 (95% confidence interval: 0.966–0.982). Forty-nine of the 155 patients underwent intravenous thrombolysis. The door-to-needle time was significantly decreased after implementation of point-of-care testing for the prothrombin time international normalized ratio (median, 23.0 min; interquartile range, 16.0–29.8 vs median, 46.0 min; interquartile range, 33.5–50.5 min). Conclusion: Utilization of point-of-care testing for the prothrombin time international normalized ratio was feasible in the management of patients with acute ischemic stroke. Point-of-care testing for the prothrombin time international normalized ratio was quick and reliable and had a pivotal role in expediting thrombolysis.


2017 ◽  
Vol 137 (2) ◽  
pp. 252-255 ◽  
Author(s):  
R. Zenlander ◽  
M. von Euler ◽  
J. Antovic ◽  
A. Berglund

2019 ◽  
Vol 4 (1) ◽  
pp. 238146831985630
Author(s):  
Reed Harder ◽  
Keji Wei ◽  
Vikrant Vaze ◽  
James E. Stahl

Background. In response to demand for fast and efficient clinical testing, the use of point-of-care testing (POCT) has become increasingly common in the United States. However, studies of POCT implementation have found that adopting POCT may not always be advantageous relative to centralized laboratory testing. Methods. We construct a simulation model of patient flow in an outpatient care setting to evaluate tradeoffs involved in POCT implementation across multiple dimensions, comparing measures of patient outcomes in varying clinical scenarios, testing regimes, and patient conditions. Results. We find that POCT can significantly reduce clinical time for patients, as compared to traditional testing regimes, in settings where clinic and central testing areas are far apart. However, as distance from clinic to central testing area decreased, POCT advantage over central laboratory testing also decreased, in terms of time in the clinical system and estimated subsequent productivity loss. For example, testing for pneumonia resulted in an estimated average of 27.80 (central lab) versus 15.50 (POCT) total lost productive hours in a rural scenario, and an average of 14.92 (central lab) versus 15.50 (POCT) hours in a hospital-based scenario. Conclusions. Our results show that POCT can effectively reduce the average time a patient spends in the system for varying condition profiles and clinical scenarios. However, the number of total lost productive hours, a more holistic measure, is greatly affected by testing quality, where POCT often is at a disadvantage. Thus, it is important to consider factors such as clinical setting, target condition, testing costs, and test quality when selecting appropriate testing regime.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Dirk Peetz

The use of biomarkers in acute chest pain and dyspnea is well established and point-of-care testing (POCT) is increasingly used in emergency departments and chest pain units for this purpose. However, few data give evidence that POCT has advantages for the patient or the medical process over central laboratory testing. Especially for troponin testing in patients with myocardial infarction, the newest guidelines define prerequisites on diagnostic test quality which most POC assays do not fulfill. Additionally, no data are available showing that POCT has relevant effect on a change of physician’s diagnostic and therapeutic thinking compared to laboratory testing. Regarding patient outcomes and societal costs, central laboratory testing seems to be even superior to POCT. The main limit of currently available POC troponin assays is the higher limit of detection and higher imprecision compared to the new high sensitive laboratory assays. However, new upcoming POC technologies may perform comparable to today’s laboratory analyzers.