scholarly journals Accuracy Evaluation of Blood Glucose Monitoring Systems in Children on Overnight Closed-Loop Control

2014 ◽  
Vol 8 (5) ◽  
pp. 969-973 ◽  
Author(s):  
Daniel J. DeSalvo ◽  
Satya Shanmugham ◽  
Trang T. Ly ◽  
Darrell M. Wilson ◽  
Bruce A. Buckingham
2012 ◽  
Vol 6 (5) ◽  
pp. 1060-1075 ◽  
Author(s):  
Guido Freckmann ◽  
Christina Schmid ◽  
Annette Baumstark ◽  
Stefan Pleus ◽  
Manuela Link ◽  
...  

2020 ◽  
Vol 8 (1) ◽  
pp. e001067 ◽  
Author(s):  
Stefan Pleus ◽  
Annette Baumstark ◽  
Nina Jendrike ◽  
Jochen Mende ◽  
Manuela Link ◽  
...  

ObjectiveAccuracy of 18 current-generation blood glucose monitoring systems (BGMS) available in Europe was evaluated applying criteria adapted from EN ISO 15197:2015 with one reagent system lot. BGMS were selected based on market research data.Research design and methodsThe BGMS ABRA, Accu-Chek Guide, AURUM, CareSens Dual, CERA-CHEK 1CODE, ContourNext One, eBsensor, FreeStyle Freedom Lite, GL50 evo, GlucoCheck GOLD, GlucoMen areo 2K, GluNEO, MyStar DoseCoach, OneTouch Verio Flex, Pic GlucoTest, Rightest GM700S, TRUEyou, and WaveSense JAZZ Wireless were tested using capillary blood from 100 different subjects and assessing the percentage of results within ±15 mg/dL (0.83 mmol/L) or 15% of comparison method results for BG concentrations below or above 100 mg/dL (5.55 mmol/L), respectively. In addition, the minimal deviation from comparison method results within which ≥95% of results of the respective BGMS were found was calculated.ResultsIn total, 14 BGMS had ≥95% of results within ±15 mg/dL (0.83 mmol/L) or ±15% and 3 BGMS had ≥95% of results within ±10 mg/dL (0.55 mmol/L) or ±10% of the results obtained with the comparison method. The smallest deviation from comparison method results within which ≥95% of results were found was ±7.7 mg/dL (0.43 mmol/L) or ±7.7%; the highest deviation was ±19.7 mg/dL (1.09 mmol/L) or ±19.7%.ConclusionsThis accuracy evaluation shows that not all CE-labeled BGMS fulfill accuracy requirements of ISO 15197 reliably and that there is considerable variation even among BGMS fulfilling these criteria. This safety-related information should be taken into account by patients and healthcare professionals when making therapy decisions.Trial registration numberNCT03737188.


2013 ◽  
Vol 7 (5) ◽  
pp. 1294-1304 ◽  
Author(s):  
Solveig Halldorsdottir ◽  
Mary Ellen Warchal-Windham ◽  
Jane F. Wallace ◽  
Scott Pardo ◽  
Joan Lee Parkes ◽  
...  

2019 ◽  
Vol 13 (3) ◽  
pp. 252-258 ◽  
Author(s):  
Huizhen Chen ◽  
Qingtao Yao ◽  
Yang Dong ◽  
Zhimei Tang ◽  
Ruiying Li ◽  
...  

2015 ◽  
Vol 6 (3) ◽  
pp. 377-388 ◽  
Author(s):  
Nancy Dunne ◽  
Maria T. Viggiani ◽  
Scott Pardo ◽  
Cynthia Robinson ◽  
Joan Lee Parkes

2017 ◽  
Vol 19 (4) ◽  
pp. 246-254 ◽  
Author(s):  
Guido Freckmann ◽  
Annette Baumstark ◽  
Nina Jendrike ◽  
Delia Rittmeyer ◽  
Stefan Pleus ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document