scholarly journals Atrial fibrillation in acute heart failure: A position statement from the Acute Cardiovascular Care Association and European Heart Rhythm Association of the European Society of Cardiology

2020 ◽  
Vol 9 (4) ◽  
pp. 348-357 ◽  
Author(s):  
Bulent Gorenek (Chair) ◽  
Sigrun Halvorsen ◽  
Gulmira Kudaiberdieva ◽  
Hector Bueno ◽  
Isabelle C Van Gelder ◽  
...  

Atrial fibrillation and acute heart failure frequently co-exist and can exacerbate each other. Their combination leads to increased morbidity and mortality. However, the prevalence and significance, as well as the treatment, of atrial fibrillation in acute heart failure are not well studied. Management of atrial fibrillation in acute heart failure requires a multidisciplinary team approach. Treatment of underlying disease(s), identification and treatment of potentially correctable causes and precipitating factors and anticoagulation are crucial. In this article, current evidence on atrial fibrillation in the setting of acute heart failure is summarised. The recommendations on management of atrial fibrillation in the prehospital stage, the treatment of reversible causes, when and how to use rate or rhythm control, maintenance of sinus rhythm, catheter ablation and pacing, anticoagulation, as well as measures on prevention of atrial fibrillation are provided.

Author(s):  
Bartosz Krzowski ◽  
Kamila Skoczylas ◽  
Gabriela Osak ◽  
Natalia Żurawska ◽  
Michał Peller ◽  
...  

Abstract Aims Mobile, portable ECG-recorders allow the assessment of heart rhythm in out-of-hospital conditions and may prove useful for monitoring patients with cardiovascular diseases. However, the effectiveness of these portable devices has not been tested in everyday practice. Methods and results A group of 98 consecutive cardiology patients (62 males [63%], mean age 69 ± 12.9 years) were included in an academic care centre. For each patient, a standard 12-lead electrocardiogram (SE), as well as a Kardia Mobile 6L (KM) and Istel (IS) HR-2000 ECG were performed. Two groups of experienced physycians analyzed obtained recordings. After analyzing ECG tracings from SE, KM, and IS, quality was marked as good in 82%, 80%, and 72% of patients, respectively (p < 0.001). There were no significant differences between devices in terms of detecting sinus rhythm (SE [60%, n = 59], KM [58%, n = 56], and IS [61%, n = 60]; SE vs KM p = 0.53; SE vs IS p = 0.76) and atrial fibrillation (SE [22%, n = 22], KM [22%, n = 21], and IS [18%, n = 18]; (SE vs KM p = 0.65; SE vs IS = 0.1). KM had a sensitivity of 88.1% and a specificity of 89.7% for diagnosing sinus rhythm. IS showed 91.5% and 84.6% sensitivity and specificity, respectively. The sensitivity of KM in detecting atrial fibrillation was higher than IS (86.4% vs. 77.3%), but their specificity was comparable (97.4% vs. 98.7%). Conclusion Novel, portable devices are useful in showing sinus rhythm and detecting atrial fibrillation in clinical practice. However, ECG measurements concerning conduction and repolarisation should be clarified with a standard 12-lead electrocardiogram.


Sign in / Sign up

Export Citation Format

Share Document