scholarly journals Total Hip Arthroplasty Using Proximal Porous Coating Stem with Distal Sleeve: Mid-Term Outcome

2009 ◽  
Vol 17 (1) ◽  
pp. 36-41 ◽  
Author(s):  
M Saito ◽  
KA Takahashi ◽  
M Fujioka ◽  
K Ueshima ◽  
K Sakao ◽  
...  

Purpose. To report mid-term results of total hip arthroplasty (THA) using the Opti-Fix Plus Hip System (Opti-Fix Hip), and to assess the correlations between peri-implant bone changes and the distal medullary occupancy rate. Methods. 11 men (13 hips) and 53 women (58 hips) aged 24 to 87 (mean, 61) years underwent THA using the Opti-Fix Hip, with a modular stem and a distal sleeve, and were followed up for a mean of 6.5 (range, 4.8–9.6) years. Clinical outcomes were evaluated using the Japanese Orthopaedic Association (JOA) hip score. Implant stability, bone changes around the implant, and the occupancy rate of the stem in the medullary space were examined radiologically. Bone changes around the implant were assessed based on the radiological evidence of a pedestal, osteolysis, stress shielding, and radiolucent lines. Results. The mean JOA score increased significantly after surgery and was maintained at the latest follow-up. Around the acetabular and femoral components respectively, 38 and 58 hips had radiolucent lines, whereas one and 54 hips developed osteolysis. A pedestal appeared in 21 hips and grade-III or higher stress shielding in 30 hips. Two hips showed loosening of the acetabular components, but none in the femoral components. Osteolysis around the stem was frequently observed in hips with poor distal medullary occupancy. Conclusion. Clinical and radiological outcomes of the Opti-Fix Hip were favourable. The low incidence of osteolysis in the distal stem suggests that the proximal circumferential porous coating was effective. Minor osteolysis around the proximal stem was frequently observed, indicating early excessive wear of the polyethylene liner. Its high distal medullary occupancy rate could inhibit stem micromotion and aseptic loosening.

2017 ◽  
Vol 27 (6) ◽  
pp. 532-536 ◽  
Author(s):  
Motoki Sonohata ◽  
Masaru Kitajima ◽  
Shunsuke Kawano ◽  
Masaaki Mawatari

Introduction Total hip arthroplasty (THA) in the young is challenging. The purpose of this study was to retrospectively determine the clinical, radiographic, and polyethylene wear rate of relatively young patients. Methods We evaluated the outcome of consecutive patients receiving primary THA who were under 40 years of age with a minimum 10-year follow-up. Indications for THA in these patients were osteoarthritis due to developmental dysplasia of the hip joint (9 hips), osteonecrosis of the femoral head (7 hips), juvenile idiopathic arthritis (2 hips), and osteoarthritis due to Perthes disease (1 hip). All THA were performed with a cross-linked ultra-high-molecular-weight polyethylene (XLPE) liner against zirconium heads with cementless implants. Results The average Japanese Orthopaedic Association hip score significantly improved from 42 to 93 points at the latest follow-up. The mean steady wear was 0.015 mm/year (maximum 0.033 mm/year), and the mean creep wear was 0.111 mm (maximum 0.4 mm). Osteolysis was observed around 1 acetabular component and 2 stems. 1 femoral component had subsidence over 5 mm. All of the femoral components achieved fixation with an optimal interface with spot welds at the latest follow-up. Stress shielding was observed in all hips. Conclusions THA using an XLPE liner against zirconium heads appeared to have improved THA longevity. However, the imaging findings in some cases were suggestive of wear debris. A rigorous continual follow-up is required for relatively young patients undergoing THA.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Kazuki Oishi ◽  
Yuji Yamamoto ◽  
Yoshifumi Harada ◽  
Ryo Inoue ◽  
Eiji Sasaki ◽  
...  

Abstract Background The objectives of this study were to assess radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis and to investigate the clinical and radiographic factors associated with radiolucent lines on tomosynthesis. Methods Fifty-five patients underwent total hip arthroplasty using a Tritanium cup, and digital tomosynthesis and plain radiography were performed at 1 week, 6 months, 1 year, and 2 years after surgery. The radiolucent lines around the cup were measured on both DTS and plain radiography at each postoperative period. Clinical evaluations were performed by the Japanese Orthopaedic Association hip disease evaluation questionnaire (JHEQ), and revision surgeries were examined. Based on the presence of radiolucent lines on digital tomosynthesis at 2 years postoperatively, patients were divided into RL (+) and RL (−) groups and investigated for related factors. Results There were 20 cases in the RL (+) group and 35 cases in the RL (−) group, and no revision surgeries were required. Statistically, there were more cases with radiolucent lines on digital tomosynthesis (45.4% at 1 week and 36.3% at 2 years) than on plain radiography (9.1% at 1 week and 9.1% at 2 years) at each postoperative point. Logistic analysis showed no significant associations between the presence of radiolucent lines at 2 years on digital tomosynthesis, and the JHEQ parameters of pain (p = 0.937), movement (p = 0.266), or mental status (p = 0.404). Conclusion In a short-term evaluation up to 2 years, digital tomosynthesis detected more radiolucent lines around the titanium cups than plain radiography. The occurrence of radiolucent lines was not related to the postoperative clinical evaluation.


2015 ◽  
Vol 44 (8) ◽  
pp. 921-929 ◽  
Author(s):  
Luca Vezzoni ◽  
Aldo Vezzoni ◽  
Randy J. Boudrieau

2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


Author(s):  
Bradley Hanks ◽  
Shantanab Dinda ◽  
Sanjay Joshi

Total hip arthroplasty (THA) is an increasingly common procedure that replaces all or part of the hip joint. The average age of patients is decreasing, which in turn increases the need for more durable implants. Revisions in hip implants are frequently caused by three primary issues: femoral loading, poor fixation, and stress shielding. First, as the age of hip implant patients decreases, the hip implants are seeing increased loading, beyond what they were traditionally designed for. Second, traditional implants may have roughened surfaces but are not fully porous which would allow bone to grow in and through the implant. Third, traditional implants are too stiff, causing more load to be carried by the implant and shielding the bone from stress. Ultimately this stress shielding leads to bone resorption and implant loosening. Additive manufacturing (AM) presents a unique opportunity for enhanced performance by allowing for personalized medicine and increased functionality through geometrically complex parts. Much research has been devoted to how AM can be used to improve surgical implants through lattice structures. To date, the authors have found no studies that have performed a complete 3D lattice structure optimization in patient specific anatomy. This paper discusses the general design of an AM hip implant that is personalized for patient specific anatomy and proposes a workflow for optimizing a lattice structure within the implant. Using this design workflow, several lattice structured AM hip implants of various unit cell types are optimized. A solid hip implant is compared against the optimized hip implants. It appears the AM hip implant with a tetra lattice outperforms the other implant by reducing stiffness and allowing for greater bone ingrowth. Ultimately it was found that AM software still has many limitations associated with attempting complex optimizations with multiple materials in patient specific anatomy. Though software limitations prevented a full 3D optimization in patient specific anatomy, the challenges associated such an approach and limitations of the current software are discussed.


Author(s):  
Mohmad Nawaz Rather ◽  
Wajahat Ahmad Mir ◽  
Shahid Shabir Khan ◽  
Naseer Ahmad Mir ◽  
Nadeem Ali

<p class="abstract"><strong>Background:</strong> Osteonecrosis of femoral head (ONFH) is characterised by cell death in the subchondral bone caused by abnormalities of blood flow to the femoral head. About 5% to 13% of arthroplasties are performed yearly for ONFH in United States. Ficat and Arlet classification is the commonest system used for grading of ONFH. Advanced stages 3 and 4 are best managed with total hip arthroplasty (THA). THA restores hip range of movement and allows early ambulation in ONFH.</p><p class="abstract"><strong>Methods:</strong> After seeking approval from local institutional ethical committee 25 patients with stage 3 and stage 4 ONFH (Ficat and Arlet) were admitted from OPD of SKIMS MC and Hospital Bemina, Srinagar. The study was conducted from February 2018 to February 2020 in department of Orthopaedics SKIMS MC and Hospital Bemina, Srinagar.  25 patients with mean age of 50.64 years comprising of 13 females and 12 males with unilateral osteonecrosis of femoral head with collapsed head underwent uncemented total hip arthroplasty and were followed up to a minimum of 1 year post-operatively.<strong></strong></p><p class="abstract"><strong>Results:</strong> Outcome was evaluated by comparing pre-operative and post-operative Harris hip scores. The average Harris hip scores improved from 65.87 in the pre-operative group to 96.54 at 1-year follow-up post-operatively. Marked improvement was noted in pain scores. No revisions were performed during the study. One patient developed superficial surgical site infection which healed with supervised dressings and oral antibiotics.</p><p class="abstract"><strong>Conclusions:</strong> Uncemented THA has excellent short-term outcomes in advanced stages of ONFH. It provides mobile hip joint and pain free ambulation shortly after surgery.</p>


2021 ◽  
Author(s):  
Keiji Kamo ◽  
Hiroaki Kijima ◽  
Koichiro Okuyama ◽  
Tetsuya Kawano ◽  
Nobutoshi Seki ◽  
...  

Abstract Background: Bone mineral density (BMD) of the proximal femur around the stem decreases due to stress shielding after cementless total hip arthroplasty (THA). When severe stress shielding occurs, the risk of periprosthetic femoral fractures increases, and this bone loss can also increase the difficulty of future revision THA. Denosumab is known to improve the quality and strength of cortical bone in the proximal femurs of patients with osteoporosis. The purpose of this study was to investigate whether denosumab prevents loss of proximal femoral periprosthetic BMD in cementless THA using a tapered wedge stem in patients with osteoporosis.Methods: Sixty-three consecutive patients who had undergone unilateral primary THA using a tapered wedge stem were included in this retrospective study. Twenty-four patients who received denosumab for osteoporosis were the denosumab group, and the 39 without denosumab were the control group. At 2 weeks, 6 months, and 12 months after THA, bone turnover markers and femoral periprosthetic BMD were measured.Results: BMD in zone 1 was significantly increased from baseline at both 6 and 12 months after THA in the denosumab group and significantly decreased in the control group. BMD in zone 7 was significantly decreased compared to baseline at both 6 and 12 months after THA in the control group, but not in the denosumab group. The use of denosumab for THA patients with osteoporosis was independently related to preventing loss of periprosthetic BMD of the femur at 12 months after surgery in zones 1 and 7 on multivariate analysis.Conclusions: Denosumab significantly increased proximal femoral periprosthetic BMD in zone 1 and prevented loss of BMD in zone 7 in patients with osteoporosis after cementless THA using a tapered wedge stem at both 6 and 12 months after surgery.


Sign in / Sign up

Export Citation Format

Share Document