scholarly journals Assessment of Cerebral Blood Flow and Oxygen Extraction in Pediatric Sickle Cell Disease with Non-Invasive Diffuse Optical Spectroscopies

Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 7-8
Author(s):  
Seung Yup Lee ◽  
Eashani Sathilingam ◽  
Kyle R. Cowdrick ◽  
Rowan O. Brothers ◽  
Wilbur A. Lam ◽  
...  

Introduction: Cerebral infarcts and associated cognitive impairments are a devastating consequence of sickle cell disease (SCD). While the underlying mechanisms are poorly understood, infarctions are thought to arise from anemia-induced microvascular perfusion abnormalities and subsequent reduced cerebrovascular reserve that is insufficient to meet tissue metabolic demands. Thus, quantification of abnormalities in microvascular cerebral blood flow (CBF) and oxygen extraction (OEF) may be useful in identifying infarct risk and monitoring therapeutic efficacy. Unfortunately, current modalities that quantify microvascular hemodynamics (e.g., PET, MRI) are prohibitively expensive, have limited availability, and require anesthesia in children <6y, making them inappropriate as routine monitoring tools. Transcranial Doppler ultrasound (TCD) is currently the standard screening tool for overt stroke risk in pediatric SCD, but it only measures blood flow velocity in the large arteries, which is a poor surrogate for microvascular perfusion in sickle cell disease. Diffuse optical spectroscopies (specifically near-infrared frequency-domain spectroscopy, FDNIRS, and diffuse correlation spectroscopy, DCS) offer a low-cost, non-invasive alternative for bedside monitoring of tissue-level OEF and CBF. We previously demonstrated that FDNIRS/DCS are sensitive to elevations in resting-state OEF and CBF in children with sickle cell disease compared to healthy controls (Lee, Neurophotonics 2019), consistent with previous studies using MRI and PET. In this feasibility study, we demonstrate these optical techniques are sensitive to altered cerebral hemodynamics in sickle patients who are 1) undergoing chronic transfusion, and 2) experiencing vaso-occlusive pain episodes (VOE). Methods: To date, we have recruited 6 pediatric patients with sickle cell disease undergoing chronic transfusion (5 females and 1 male, 6 - 14 y, mean ± std hemoglobin change pre- to post-transfusion = 1 ± 0.8 g/dL) and 4 patients admitted to the Emergency department for VOE (2 females and 2 males, 8 - 18 y, mean±std hemoglobin on admission = 8.9 ± 1.6 g/dL). For the transfusion cohort, FDNIRS/DCS measurements were made immediately prior to the start of transfusion and again immediately upon completion. For the VOE cohort, FDNIRS/DCS measurements were made upon hospital admission. For all FDNIRS/DCS assessments, a custom sensor was manually held over right and left forehead to assess oxygen extraction fraction (OEF, %) and an index of microvascular cerebral blood flow (CBFi, cm2/s) (Lee, Neurophotonics 2019). Hemispheric results were averaged to yield a mean of each measured parameter. Total measurement time was less than 15 minutes. Results: In the cohort undergoing chronic transfusion, one patient data was excluded due to poor DCS signal quality. Of the remaining 5 patients, OEF and CBFi decreased after transfusion by a median of -6.4% and -30.0%, respectively (Fig 1A, B). The FDNIRS-measured OEF decrease is comparable to previous results with MRI (Guilliams, Blood 2017) that quantified both cortical OEF and CBF response to transfusion in a similarly aged cohort. However, the DCS-measured CBFi decrease is more prominent than previously reported (30% vs. 9%). The enhanced sensitivity of DCS to CBF in sickle cell disease was reported in our recent study and is likely attributed to the confounding influences of hematocrit on the DCS-measured CBFi (Sathialingam, Biomed Opt Exp 2020). In the cohort measured during VOE, one patient data was excluded due to poor FDNIRS data quality. Of the remaining 3 subjects, OEF was elevated compared to healthy controls and was on the upper range of values measured in a cohort of otherwise subjects with sickle cell disease who were without clinical complications and were measured as part of a separate study (Fig. 1C). Conclusion: These data demonstrate how FDNIRS/DCS may be used as a simple, low-cost tool for bedside assessment of cerebral hemodynamics in non-sedated sickle children that could be used to track brain health over time, particularly during periods thought to be prone to hemodynamic instability like transfusion or VOEs. Although ~20% of data was discarded in this dataset due to improper sensor positioning leading to poor signal quality, we have recently implemented real-time quality control feedback to ensure our data passes quality criteria. Disclosures Lam: Sanguina, Inc: Current equity holder in private company.

Blood ◽  
1997 ◽  
Vol 89 (12) ◽  
pp. 4591-4599 ◽  
Author(s):  
James A. French ◽  
Dermot Kenny ◽  
J. Paul Scott ◽  
Raymond G. Hoffmann ◽  
James D. Wood ◽  
...  

Abstract The etiology of stroke in sickle cell disease is unclear, but may involve abnormal red blood cell (RBC) adhesion to the vascular endothelium and altered vasomotor tone regulation. Therefore, we examined both the adhesion of sickle (SS)-RBCs to cerebral microvessels and the effect of SS-RBCs on cerebral blood flow when the nitric oxide (NO) pathway was inhibited. The effect of SS-RBCs was studied in the rat cerebral microcirculation using either a cranial window for direct visualization of infused RBCs or laser Doppler flowmetry (LDF ) to measure RBC flow. When fluorescently labeled human RBCs were infused into rats, SS-RBCs had increased adhesion to rat cerebral microvessels compared with control AA-RBCs (P = .01). Next, washed SS-RBCs or AA-RBCs were infused into rats prepared with LDF probes after pretreatment (40 mg/kg intravenously) with the NO synthase inhibitor, N-ω-nitro-L-arginine methyl ester (L-NAME), or the control isomer, D-NAME. In 9 rats treated with systemic L-NAME and SS-RBCs, 5 of 9 experienced a significant decrease in LDF and died within 30 minutes after the RBC infusion (P = .0012). In contrast, all control groups completed the experiment with stable LDF and hemodynamics. Four rats received a localized superfusion of L-NAME (1 mmol/L) through the cranial window followed by infusion of SS-RBCs. Total cessation of flow in all observed cerebral microvessels occurred in 3 of 4 rats within 15 minutes after infusion of SS-RBCs. We conclude that the NO pathway is critical in maintaining cerebral blood flow in the presence of SS-RBCs in this rat model. In addition, the enhanced adhesion of SS-RBCs to rat brain microvessels may contribute to cerebral vaso-occlusion either directly, by disrupting blood flow, or indirectly, by disturbing the vascular endothelium.


2010 ◽  
Vol 95 (Suppl 1) ◽  
pp. A5.2-A5
Author(s):  
VS L'Esperance ◽  
F Kirkham ◽  
C Hill ◽  
S Cox ◽  
J Makani ◽  
...  

1994 ◽  
Vol 9 (3) ◽  
pp. 337-338 ◽  
Author(s):  
Stephen Ashwal ◽  
Antranik Bedros ◽  
Joseph Thompson

Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 2705-2705
Author(s):  
Jonathan R. Lindner ◽  
Michael Widlansky ◽  
Melinda D. Wu ◽  
Jillian Dargatz ◽  
Leanne M. Harmann ◽  
...  

Abstract Background: Outcome measures for therapeutic studies in patients with sickle cell disease (SCD) are poor.Abnormal microvascular blood flow (MBF), the basis for tissue ischemia and injury associated with vaso-occlusion, would be an optimal outcome measure for SCD studies. Ideally, a modality to measure blood flow in SCD would non-invasively quantify microvascular tissue perfusion rather than assess conduit arterial flow through large vessels. Limitations of existing techniques to measure blood flow prevent their widespread use in clinical trials of patients with SCD. Contrast-enhanced ultrasound (CEU) is a non-invasive and portable technique that uses standard ultrasound equipment to measure microvascular perfusion and functional capillary patency. The primary objective of this study was to determine whether CEU is able to detect differences in the MBF of skeletal muscle: 1) before and after infusion with the adenosine A2A receptor (A2AR) agonist regadenoson, and 2) between steady state and vaso-occlusive crisis (VOC). Methods: CEU measurements were obtained in forearm skeletal muscle in adult HbSS patients. Two measures are used to calculate MBF: 1) velocity of RBCs through capillaries and 2) volume of blood perfused in an area of tissue. MBF is the product of RBC velocity and volume of blood. In one study cohort, MBF was measured in steady-state patients during a 24-hour infusion of regadenoson (1.44 µg/kg/hour). CEU perfusion imaging was obtained at baseline, 6 and 24 hours after initiation of regadenoson. In the second study cohort, CEU measurements were obtained within the same patient during a hospital admission for VOC and at steady state. MBF was expressed in terms of a ratio to baseline flow (pre-regadenoson) in cohort 1 and as a ratio of VOC to steady-state flow for cohort 2. Results: CEU measurements were obtained in13 patients administered regadenoson, and 7 patients at steady state and during VOC. Median age (range) of all patients studied was 24 years (20-45) and 55% were female. During regadenoson infusion, there was a median increase in skeletal muscle MBF of 29% at 6 hours (ratio 1.29, IQR 0.81) and 9% at 24 hours (ratio 1.09, IQR 1.40). Increase in MBF during regadenoson administration was largely due to higher RBC velocity (6 hours ratio: 1.24, IQR 0.88; 24 hours: ratio 1.12 IQR 0.85). There was a median decrease of 40% in skeletal muscle blood flow during VOC compared to steady state (ratio 0.60, IQR 0.27). Similarly, a decrease in RBC velocity accounted for most of the reduction in MBF in VOC compared to steady state (ratio 0.63, IQR 0.35). Conclusion: CEU measures of skeletal muscle MBF increased during a 24-hour infusion of regadenoson and decreased in VOC compared to steady state. Changes in RBC velocity, as opposed to the volume of blood perfused, accounted for most of the differences in MBF seen during regadenoson infusion and VOC. Alterations in rheology or vascular tone could explain these changes. These data provide additional evidence for the A2AR agonist regadenoson as a therapeutic modality for patients with SCD and suggest that CEU is a valid measure of blood flow in VOC. Taken together, the findings of this preliminary study demonstrate that CEU, a non-invasive, portable technique to measure MBF, could be used as an objective outcome measure for therapeutic studies in SCD. Disclosures Field: NKTT: Consultancy, Research Funding. Off Label Use: IND for regadenoson for treatment of VOC in sickle cell disease.


2012 ◽  
Vol 38 (8) ◽  
pp. 1333-1338 ◽  
Author(s):  
Florian Doepp ◽  
Christian Kebelmann-Betzing ◽  
Anatol Kivi ◽  
Stephan J. Schreiber

Sign in / Sign up

Export Citation Format

Share Document