Late Breaking Abstract - Spatial response to small and large particle bronchodilator in subjects with asthma

Author(s):  
Claire O'Sullivan ◽  
Kris Nilsen ◽  
Kim Prisk ◽  
Andreas Voskrebenzev ◽  
Jens Vogel-Claussen ◽  
...  
1976 ◽  
Vol 15 (05) ◽  
pp. 246-247
Author(s):  
S. C. Jain ◽  
G. C. Bhola ◽  
A. Nagaratnam ◽  
M. M. Gupta

SummaryIn the Marinelli chair, a geometry widely used in whole body counting, the lower part of the leg is seen quite inefficiently by the detector. The present paper describes an attempt to modify the standard chair geometry to minimise this limitation. The subject sits crossed-legged in the “Buddha Posture” in the standard chair. Studies with humanoid phantoms and a volunteer sitting in the Buddha posture show that this modification brings marked improvement over the Marinelli chair both from the point of view of sensitivity and uniformity of spatial response.


2021 ◽  
pp. 127284
Author(s):  
E. Litvinova Mitra ◽  
E.J. Kolmes ◽  
I.E. Ochs ◽  
M.E. Mlodik ◽  
T. Rubin ◽  
...  

Science ◽  
1996 ◽  
Vol 272 (5268) ◽  
pp. 1601-1606 ◽  
Author(s):  
FAUNMAP Working Group: ◽  
R. W. Graham ◽  
E. L. Lundelius ◽  
M. A. Graham ◽  
E. K. Schroeder ◽  
...  

2006 ◽  
Vol 291 (1) ◽  
pp. F236-F245 ◽  
Author(s):  
R. Lance Miller ◽  
Ping Zhang ◽  
Tong Chen ◽  
Andreas Rohrwasser ◽  
Raoul D. Nelson

The structural and functional heterogeneity of the collecting duct present a tremendous experimental challenge requiring manual microdissection, which is time-consuming, labor intensive, and not amenable to high throughput. To overcome these limitations, we developed a novel approach combining the use of transgenic mice expressing green fluorescent protein (GFP) in the collecting duct with large-particle-based flow cytometry to isolate pure populations of tubular fragments from the whole collecting duct (CD), or inner medullary (IMCD), outer medullary (OMCD), or connecting segment/cortical collecting duct (CNT/CCD). Kidneys were enzymatically dispersed into tubular fragments and sorted based on tubular length and GFP intensity using large-particle-based flow cytometry or a complex object parametric analyzer and sorter (COPAS). A LIVE/DEAD assay demonstrates that the tubules were >90% viable. Tubules were collected as a function of fluorescent intensity and analyzed by epifluorescence and phase microscopy for count accuracy, GFP positivity, average tubule length, and time required to collect 100 tubules. Similarly, mRNA and protein from sorted tubules were analyzed for expression of tubule segment-specific genes using quantitative real-time RT-PCR and immunoblotting. The purity and yield of sorted tubules were related to sort stringency. Four to six replicates of 100 collecting ducts (9.68 ± 0.44–14.5 ± 0.66 cm or 9.2 ± 0.7 mg tubular protein) were routinely obtained from a single mouse in under 1 h. In conclusion, large-particle-based flow cytometry is fast, reproducible, and generates sufficient amounts of highly pure and viable collecting ducts from single or replicate animals for gene expression and proteomic analysis.


2011 ◽  
Vol 11 (3) ◽  
pp. 184-188
Author(s):  
Syed F. Akber ◽  
Than S. Kehwar

AbstractThe partial volume (spatial) response of four ionization chambers (Keithley) in kilovoltage X-ray beams, generated by the Philips Super 80CP X-ray unit, was assessed. The volume of the ionization chambers were of 10 cm3, 15 cm3, 150 cm3, and 600 cm3 used with Keithley electrometer Model 35040. The beam output was measured using a monitor chamber (Radcal 6.0 cm3) placed close to the collimator. The source to chamber distance was kept constant at 1 m. For the measurement of the response of ionization chambers of 15 cm3, 150 cm3, and 600 cm3, a slit of 2.0 mm width was made in a lead sheet of 3.2 mm thick and size of 30 × 30 cm2 and was placed on the ionization chamber. The measurements were made for 81 kVp, 400 mA, and 0.25 s and the slit was moved at an increment of 2.0 mm over the entire length of the chamber. For the measurements of the ionization chamber of 10 cm3 (CT chamber), the beams of 120 kVp, 200 mA and 0.2 s were generated, and a slit of 5 mm width was made in a similar lead sheet that was moved at an increment of 5.0 mm. From the result it appears that the sensitive volumes of the ionization chambers affect the response of the ionization chamber to incident radiation.


Sign in / Sign up

Export Citation Format

Share Document