scholarly journals Assessment of the retinal vasculature in healthy Chinese preschool children aged 4–6 years old using optical coherence tomography angiography

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Lu Xiang ◽  
Yingming Zhou ◽  
Yanwei Chen ◽  
Siyu Jiang ◽  
Chunli Fei ◽  
...  

Abstract Purpose To establish normal parameters of macular and optic disc vasculature by optical coherence tomography angiography (OCTA) in healthy preschool children aged 4–6 years old in China. OCTA reflects retinal metabolism and development in children at these ages and could be used clinically and in future studies to aid diagnosis and prediction of retinal abnormalities and developmental stagnation. Methods In this cross-sectional study, we measured foveal, parafoveal, and perifoveal vessel density in the superficial capillary plexus (SCP); the deep capillary plexus (DCP), the foveal avascular zone (FAZ), and the radial capillary peripapillary (RPC) in the optic disc using investigational spectral-domain OCTA. The magnification effect of the FAZ area and microvasculature measurements was corrected by Littman and the modified Bennett formula. Results A total of 242 eyes (116 males and 126 females, 5.31 ± 0.73 years) were recruited for the analysis. The mean macular vessel density was 48.10 ± 2.92% and 48.74 ± 6.51% in the SCP and the DCP, respectively. The RPC vessel density was 47.17 ± 2.52%, 47.99 ± 4.48%, and 48.41 ± 3.07% in the whole image, inside disc, and peripapillary, respectively; and the mean FAZ area was 0.28 ± 0.11 mm2. A significant difference between male and female participants was found in the retinal vasculature (DCP, SCP, and RPC). None of these parameters were significantly different in age (P > 0.05), except that DCP slightly increased with aging. The right and left eyes had good consistency in the parameters of the macula and optic disc. Conclusions Our study establishes the macular and optic disc OCTA reference values in 4- to 6-year-old healthy preschool children. They may be used in longitudinal OCTA studies and clinical applications.

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Lun Liu ◽  
Jian Gao ◽  
Weili Bao ◽  
Chengyang Hu ◽  
Yajing Xu ◽  
...  

Purpose. To analyze foveal microvascular abnormalities in different stages of diabetic retinopathy (DR) using optical coherence tomography angiography (OCTA) with projection artifact removal (PAR). Methods. We analyzed 93 eyes of 59 patients with diabetes—31 with no DR (no DR), 34 with mild to moderate nonproliferative DR (mild DR), and 28 with severe nonproliferative DR to proliferative DR (severe DR)—and 31 age-matched healthy controls. Sections measuring 3 × 3 mm2 centered on the fovea were obtained using OCTA. The area, perimeter, and acircularity index (AI) of the foveal avascular zone (FAZ), vessel density within a 300 μm wide region of the FAZ (FD-300), and parafoveal vessel density in the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were calculated using novel built-in software with PAR. Results. There was no statistically significant difference in the FAZ area (p=0.162). There was a statistically significant difference in the FAZ perimeter (p=0.010) and the AI (p<0.001) between the four groups. There was a correlation between the AI and the increasing severity of DR (p=0.010). Statistically significant decreases of vessel density in the FD-300, SCP, and DCP were observed (all p<0.001). There was a difference in parafoveal vessel density in the DCP between the healthy control eyes and the eyes with diabetes without DR (p=0.027). There was a significant correlation between vessel density and increasing severity of DR (p<0.001). Conclusion. Compared with the FAZ area, AI allows a more helpful quantitative assessment of the changes in the FAZ. Vessel density determined using OCTA with PAR might be a useful parameter indicating the progression of DR. Parafoveal vessel density in the DCP after PAR might be a potential early biomarker of DR before appearance of clinically evident retinopathy and needs further investigation.


2021 ◽  
Author(s):  
Yadollah Eslami ◽  
Sepideh Ghods ◽  
Massood Mohammadi ◽  
Mona Safizadeh ◽  
Ghasem Fakhraie ◽  
...  

Abstract Purpose: To evaluate the relationship between structure and function in moderate and advanced primary open-angle glaucoma (POAG) and to determine the accuracy of structure and vasculature for discriminating moderate from advanced POAG.Methods: In this cross-sectional study 25 eyes with moderate and 40 eyes with advanced POAG were enrolled. All eyes underwent measurement of the thickness of circumpapillary retinal nerve fiber layer (cpRNFL) and macular ganglion cell complex (GCC), and optical coherence tomography angiography (OCTA) of the optic nerve head (ONH) and macula. Visual field (VF) was evaluated by Swedish interactive threshold algorithm and 24-2 and 10-2 patterns. The correlation between structure and vasculature and the mean deviation (MD) of the VFs was evaluated by a partial correlation coefficient. The area under the receiver operating characteristic curve (AUC) was applied for assessing the power of variables for discrimination moderate from advanced POAG.Results: Superior cpRNFL, superior GCC, whole image vessel density (wiVD) of the ONH area, and vessel density in inferior quadrant of perifovea had the strongest correlation with the mean deviation (MD) of the VF 24-2 (r= .351, .558, .649 and .397; p< .05). The greatest AUCs belonged to inferior cpRNFL (.789), superior GCC (.818), vessel density of the inferior hemifield of ONH area (.886), and vessel density in inferior quadrant of perifovea (.833) without statistically significant difference in pairwise comparison.Conclusion: Vasculature has a stronger correlation than the structure with MD in moderate and advanced POAG and is as accurate as structure in discrimination moderate from advanced POAG.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Sijie Cai ◽  
Fengping Zhao ◽  
Chixin Du

Abstract Background To determine the repeatability of measurements of ocular surface vessel density in normal and diseased eyes using optical coherence tomography angiography (OCTA). Methods Ten normal eyes, 10 pinguecula eyes, and 10 pterygium eyes of 30 volunteers were subjected to OCTA (AngioVue Imaging System, Optovue, Inc.). For scanning, we used the corneal adapter module. Each eye was scanned three times in the nasal and temporal directions, separately. AngioVue software was used to generate the ocular surface vessel density. Ocular surface vessel density was defined as the proportion of vessel area with blood flow to the total measurement area (3 × 3 mm2). Intersession repeatability of the measurement was summarized as the coefficient of variation (CV), and intraclass correlation coefficients (ICC) were calculated by variance component models. Results The CVs were less than 5% in all subjects, and the ICCs exceeded 0.9; thus, all measurements showed good repeatability. The nasal vessels densities differed significantly between healthy eyes and eyes with pterygium (P < 0.05); however, there was no significant difference between healthy eyes and eyes with pinguecula (P = 0.466). Conclusions These results suggest that measurement of ocular surface vessel density by OCTA in normal eyes and eyes with pterygium and pinguecula is repeatable. This preliminary research describes a quantitative and visual method for assessing vessel density of the ocular surface with a high level of consistency.


2019 ◽  
Vol 30 (6) ◽  
pp. 1418-1423 ◽  
Author(s):  
Claudio Furino ◽  
Grazia Montrone ◽  
Maria Vittoria Cicinelli ◽  
Stefania Balestra ◽  
Maria Oliva Grassi ◽  
...  

Purpose: To investigate a subset of diabetic patients without diabetic retinopathy with optical coherence tomography angiography, assessing the differences in macular perfusion between diseased eyes and healthy controls. Methods: Monocentric cross-sectional study, including 86 eyes from 43 diabetic patients with no clinical signs of diabetic retinopathy and 78 eyes from 39 controls. Patients underwent 3.0 × 3.0 mm and 4.5 × 4.5 mm swept-source optical coherence tomography angiography. Vessel density (%), foveal avascular zone area (mm2), and avascular density (%) were provided for the superficial capillary plexus and the deep capillary plexus. Results: The foveal avascular zone area at the superficial capillary plexus was larger in the study group compared to controls, irrespective of the area of the slab considered. A meaningful difference was found in the vessel density at the deep capillary plexus of the 3.0 × 3.0 mm slab (p = 0.03). Almost all the variables considered in the study showed a significant within-subject effect. Age significantly correlated with vessel density of superficial capillary plexus on 4.5 × 4.5 mm in both control and diabetic eyes. Conclusion: Diabetic patients with subclinical diabetic retinopathy feature a larger foveal avascular zone at the superficial capillary plexus compared with controls, as well as relative reduction of the vessel density at the deep capillary plexus. These findings might serve as the basis for screening between normal and diabetic subjects.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
A. R. Kee ◽  
V. C. H. Yip ◽  
E. L. T. Tay ◽  
C. W. Lim ◽  
J. Cheng ◽  
...  

Abstract Background To understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability. Methods A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated. Results A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761–1.000) compared to Swept Source (0.113–0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source. Conclusions AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Jingyuan Yang ◽  
Mingzhen Yuan ◽  
Erqian Wang ◽  
Youxin Chen

The aim of this study was to compare the repeatability of optical coherence tomography angiography (OCT-A) measurements of macular vessel density using four OCT-A systems, including Heidelberg Spectralis HRA, Optovue RTVue XR, Zeiss Cirrus HD-OCT 5000, and Topcon DRI OCT Triton. A cross-sectional design was used for this study. The vascular density and vascular length density of the superficial and deep retinal capillary plexuses were imaged with OCT-A using 3 mm and 6 mm scan patterns and were calculated using ImageJ. Comparisons of intraclass correlation coefficients (ICC) were conducted. We found that the OCT-A systems had various levels of repeatability. Zeiss had better repeatability for vessel density than the other systems (overall ICC = 0.936). Optovue had better repeatability for vessel length density when the 6 mm scan pattern was used (ICC = 0.680 and 0.700 for retinal superficial and deep capillary plexus, respectively). We concluded that repeatability varied when different scan patterns of various OCT-A systems were used for imaging the superficial retinal and deep capillary plexuses. Results should be seen as valid only for a given method. The repeatability of various OCT-A systems should be considered in clinical practice and in clinical trials that use OCT-A metrics as outcome measures.


2019 ◽  
Vol 103 (11) ◽  
pp. 1677-1684 ◽  
Author(s):  
Ana I M Miguel ◽  
André B Silva ◽  
Luis F Azevedo

BackgroundCompared with current imaging methods, the diagnostic performance and the advantages and limitations of optical coherence tomography angiography (OCTA) remain unclear. We performed a systematic review and meta-analysis of studies investigating vessel density (VD) in patients with glaucoma using OCTA.MethodsWe conducted a literature search on PubMed, Scopus, Web of Science, ISI Conference Proceedings and Google Scholar, along with a manual search, from January 2006 to March 2018. We included prospective studies that used OCTA to compare the VD in glaucomatous eyes with healthy control eyes.ResultsOf 3045 screened articles, 24 were included in a broad characterisation and 18 in the meta-analysis. We observed a statistically significant reduction in the mean peripapillary VD (MPVD) in glaucoma (MPVD: 57.53%, 95% CI 52.60 to 62.46, p< 0.001) compared with controls (MPVD: 65.47%, 95% CI 59.82 to 71.11; standardised mean difference [SMD], –1.41, 95% CI –1.62 to –1.20, p< 0.001) for 888 glaucomatous and 475 healthy eyes, and also in the mean-whole optic nerve image VD (SMD, –9.63, 95% CI –10.22 to –9.03, p<0.001), mean inside-disc VD (SMD, − 9.51, 95% CI –12.66 to –6.36, p<0.05) and mean parafoveal VD (SMD, –3.92, 95% CI –4.73 to –3.12, p<0.001). Subgroup analyses revealed a significant difference in the MPVD across glaucoma subtypes and OCTA devices.ConclusionThis suggests the diagnostic utility of OCTA in detecting glaucomatous eyes; however, further longitudinal prospective studies are welcomed to characterise vascular changes in glaucoma.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243830
Author(s):  
Yining Dai ◽  
Hao Zhou ◽  
Qinqin Zhang ◽  
Zhongdi Chu ◽  
Lisa C. Olmos de Koo ◽  
...  

Purpose To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). Methods Diabetic subjects with different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans. Results Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8μm2 vs 1574.4±255.0 μm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively). Conclusions CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.


2019 ◽  
Author(s):  
Ehsan Vaghefi ◽  
Sophie Hill ◽  
Hannah M Kersten ◽  
David Squirrell

AbstractPurposeTo determine whether vessel density (VD) as measured by optical coherence tomography angiography (OCT-A) provide insights into retinal and choriocapillaris vascular changes with ageing and intermediate dry age related macular degeneration (AMD).MethodsSeventy-five participants were recruited into three cohorts; young healthy (YH) group, old healthy (OH) and those at high-risk for exudative AMD. Raw OCT and OCT-A data from TOPCON DRI OCT Triton were exported using Topcon IMAGENET 6.0 software, and 3D datasets were analysed to determine retinal thickness and vessel density.ResultsCentral macular thickness measurements revealed a trend of overall retinal thinning with increasing age. VD through the full thickness of the retina was highest in ETDRS sector 4 (the inferior macula) in all the cohorts. Mean VD was significantly higher in the deep capillary plexus than the superficial capillary plexus in all ETDRS sectors in all cohorts but there was no significant difference noted between groups. Choriocapillaris VD was significantly lower in all ETDRS sectors in the in the AMD group compared with the YH and the OH groups.ConclusionsRetinal vessel density maps, derived from the retinal plexi are not reliable biomarkers for assessing the ageing macular. Our non-proprietary analysis of the vascular density of the choriocapillaris revealed a significant drop off of VD with age and disease but further work is required to corroborate this finding. If repeatable, choriocapillaris VD may provide a non-invasive biomarker of healthy ageing and disease.Brief SummaryIn this manuscript, we have studied the potential of retinal vessel density as measured by optical coherence tomography angiography (OCT-A), as a biomarker for detection of high-risk of developing exudative age-related macular degeneration (AMD).


Sign in / Sign up

Export Citation Format

Share Document