scholarly journals Real-time shear wave ultrasound elastography: a new tool for the evaluation of diaphragm and limb muscle stiffness in critically ill patients

Critical Care ◽  
2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Aurelien Flatres ◽  
Yassir Aarab ◽  
Stephanie Nougaret ◽  
Fanny Garnier ◽  
Romaric Larcher ◽  
...  
Critical Care ◽  
2020 ◽  
Vol 24 (1) ◽  
Author(s):  
Aurelien Flatres ◽  
Yassir Aarab ◽  
Stephanie Nougaret ◽  
Fanny Garnier ◽  
Romaric Larcher ◽  
...  

2020 ◽  
Vol 44 (8) ◽  
pp. 1484-1491 ◽  
Author(s):  
Liam McKeever ◽  
Sarah J. Peterson ◽  
Sofia Cienfuegos ◽  
Jaime Rizzie ◽  
Omar Lateef ◽  
...  

2018 ◽  
Vol 24 (10) ◽  
pp. 2183-2190 ◽  
Author(s):  
Yu-jun Chen ◽  
Ren Mao ◽  
Xue-hua Li MD ◽  
Qing-hua Cao ◽  
Zhi-hui Chen ◽  
...  

2017 ◽  
Vol 43 (6) ◽  
pp. 1105-1111 ◽  
Author(s):  
Chueh-Hung Wu ◽  
Yu-Chun Ho ◽  
Ming-Yen Hsiao ◽  
Wen-Shiang Chen ◽  
Tyng-Guey Wang

2005 ◽  
Vol 33 (2) ◽  
pp. 229-234 ◽  
Author(s):  
R. J. Young ◽  
M. J. Chapman ◽  
R. Fraser ◽  
R. Vozzo ◽  
D. P. Chorley ◽  
...  

Delivery of enteral nutrition in critically ill patients is often hampered by gastric stasis necessitating direct feeding into the small intestine. Current techniques for placement of post-pyloric feeding catheters are complex, time consuming or both, and improvements in feeding tube placement techniques are required. The Cathlocator™ is a novel device that permits real time localisation of the end of feeding tubes via detection of a magnetic field generated by a small electric current in a coil incorporated in the tip of the tube. We performed a pilot study evaluating the feasibility of the Cathlocator™ system to guide and evaluate the placement of (1) nasoduodenal feeding tubes, and (2) nasogastric drainage tubes in critically ill patients with feed intolerance due to slow gastric emptying. A prospective study of eight critically ill patients was undertaken in the intensive care unit of a tertiary hospital. The Cathlocator™ was used to (1) guide the positioning of the tubes post-pylorically and (2) determine whether nasogastric and nasoduodenal tubes were placed correctly. Tube tip position was compared with data obtained by radiology. Data are expressed as median (range). Duodenal tube placement was successful in 7 of 8 patients (insertion time 12.6 min (5.3–34.4)). All nasogastric tube placements were successful (insertion time 3.4 min (0.6–10.0)). The Cathlocator™ accurately determined the position of both tubes without complication in all cases. The Cathlocator™ allows placement and location of an enteral feeding tube in real time in critically ill patients with slow gastric emptying. These findings warrant further studies into the application of this technique for placement of post-pyloric feeding tubes.


2012 ◽  
Vol 38 (6) ◽  
pp. 933-942 ◽  
Author(s):  
Kunwar S.S. Bhatia ◽  
Edmund H.Y. Yuen ◽  
Carmen C.M. Cho ◽  
Cina S.L. Tong ◽  
Yolanda Y.P. Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document