scholarly journals An efficient HILIC-MS/MS method for the trace level determination of three potential genotoxic impurities in aripiprazole active drug substance

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Sumanth Mullangi ◽  
Kunta Ravindhranath ◽  
Ravi Kiran Panchakarla

AbstractA sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was developed and validated for trace analysis of potential genotoxic impurities (PGIs): 2,3-dichloroaniline (PGI-1), bis(2-chloroethyl) amine (PGI-2), and 2-chloroethylamine (PGI-3), in aripiprazole (APZ) active drug substance. Separation of analytes was achieved on ACE HILIC–N Column (HILN-5-1046U, 100 × 4.6 mm, 5 μm) in gradient elution mode with mobile phase A [acetonitrile:ammonium formate buffer (95:5 v/v)] and mobile phase B [acetonitrile:ammonium formate buffer (50:50 v/v)] at a flow rate of 0.8 mL/min. Developed method was linear in the concentration range of 8–100 ppm for PGI-1, 11–100 ppm for PGI-2, and 12.5–100ppm for PGI-3 with R2 > 0.996. The developed method was accurate for quantification of each PGI with percent recoveries greater than 96% and RSD (%) not more than 5%. The developed method was precise for quantification of PGIs in aripiprazole with RSD (%) of not more than 4% for any of the PGIs. There was no interference of diluent peaks at the retention time of the PGIs and APZ in the method. All the PGIs and sample solutions were found to be stable at ambient laboratory temperature (25 ± 5 °C) and refrigerated condition (2–8 °C) for a period of 48 h. The developed HILIC-MS/MS method can be used for trace quantification of PGIs in aripiprazole drug in quality control laboratories of the pharmaceutical industry.

Author(s):  
SIVA JYOTHI N. ◽  
VENKATNARAYANA MUVVALA

Objective: The main objective of current research work is to develop and validate a rapid, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the trace analysis of four potential genotoxic impurities in Atazanavir Sulfate drug substance. Methods: LC-MS/MS analysis of four potential genotoxic impurities was done on Acquity UPLC CSH C18 (100 mm × 2.1 mm, 1.7 μm) column. In this method, mobile phase A (10 mM ammonium acetate) mobile phase B (methanol: acetonitrile (90:10, v/v) with gradient run with the flow rate of 0.2 ml/min. The method was developed with the short run time of 13 min. Triple quadrupole mass detector coupled with positive electrospray ionization was used for the quantification of genotoxic impurities in multiple reaction monitoring (MRM) mode. Results: The method was linear in the range of 0.3 ppm to 4.5 ppm for BOC Hydrazine Acid impurity, BOC Epoxide and Keto impurity with a correlation coefficient not less than 0.9994. The accuracy of the method was in the range of 99.26% to 105.71% for all four potential genotoxic impurities (PGIs). No impurities were identified in the Atazanavir Sulfate active pharmaceutical ingredient sample. Conclusion: The proposed method is specific, linear, precise, accurate, robust and stable for the quantification of the four genotoxic impurities at very low levels.


2006 ◽  
Vol 89 (4) ◽  
pp. 1116-1119 ◽  
Author(s):  
Xi Xia ◽  
Xiaowei Li ◽  
Jianzhong Shen ◽  
Suxia Zhang ◽  
Shuangyang Ding ◽  
...  

Abstract A reliable and sensitive method was developed for determination of nitroimidazoles in porcine urine. Sample preparation involves an extraction with ethyl acetate, followed by a solid-phase extraction cleanup step. The final extract is injected into the liquid chromatography/tandem mass spectrometry system in the positive-ion electrospray ionization mode. A C8 column with water and acetonitrile as the mobile phase is used for chromatographic separation under gradient conditions. Overall average recoveries ranged from 83 to 107%. The limits of detection ranged from 0.03 to 0.05 ng/mL, and the limits of quantitation, from 0.1 to 0.2 ng/mL.