scholarly journals Correction to: Stress and pore fluid pressure control of seismicity rate changes following the 2016 Kumamoto earthquake, Japan

2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Kodai Nakagomi ◽  
Toshiko Terakawa ◽  
Satoshi Matsumoto ◽  
Shinichiro Horikawa

An amendment to this paper has been published and can be accessed via the original article.

2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Kodai Nakagomi ◽  
Toshiko Terakawa ◽  
Satoshi Matsumoto ◽  
Shinichiro Horikawa

AbstractWe quantitatively examined the influence of pore fluid pressure and coseismic stress changes on the seismicity rate changes that followed the 2016 Kumamoto earthquake, on the basis of two approaches. One is a numerical calculation of the classic stress metric of ∆CFS, and the other is an inversion analysis of pore fluid pressure fields with earthquake focal mechanism data. The former calculation demonstrated that seismicity rate changes were consistent with the expectation from ∆CFS in 65% of the target region, whereas they were not in the remaining 35% of the region. The latter analysis indicates that seismicity rates increased in the regions where pore fluid pressure before the Kumamoto earthquake sequence was remarkably enhanced above hydrostatic, regardless of values of ΔCFS. This suggests that the increase in pore fluid pressure is one of the important physical mechanisms triggering aftershock generation. We obtained evidence that pore fluid pressure increased around the southern part of the main rupture zone after the mainshock, examining temporal changes in types of focal mechanism data. The average increases in pore fluid pressure were estimated to be 17, 20, and 17 MPa at depths of 5, 10, and 15 km, respectively. These large increases in pore fluid pressure cannot be explained under the undrained condition. The spatial derivative of the pore fluid pressure field in the depth direction implies that fluid supply from greater depths may have controlled increases in seismicity rates that followed the large earthquake.


2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Yasuhira Aoyagi ◽  
Haruo Kimura ◽  
Kazuo Mizoguchi

Abstract The earthquake rupture termination mechanism and size of the ruptured area are crucial parameters for earthquake magnitude estimations and seismic hazard assessments. The 2016 Mw 7.0 Kumamoto Earthquake, central Kyushu, Japan, ruptured a 34-km-long area along previously recognized active faults, eastern part of the Futagawa fault zone and northernmost part of the Hinagu fault zone. Many researchers have suggested that a magma chamber under Aso Volcano terminated the eastward rupture. However, the termination mechanism of the southward rupture has remained unclear. Here, we conduct a local seismic tomographic inversion using a dense temporary seismic network to detail the seismic velocity structure around the southern termination of the rupture. The compressional-wave velocity (Vp) results and compressional- to shear-wave velocity (Vp/Vs) structure indicate several E–W- and ENE–WSW-trending zonal anomalies in the upper to middle crust. These zonal anomalies may reflect regional geological structures that follow the same trends as the Oita–Kumamoto Tectonic Line and Usuki–Yatsushiro Tectonic Line. While the 2016 Kumamoto Earthquake rupture mainly propagated through a low-Vp/Vs area (1.62–1.74) along the Hinagu fault zone, the southern termination of the earthquake at the focal depth of the mainshock is adjacent to a 3-km-diameter high-Vp/Vs body. There is a rapid 5-km step in the depth of the seismogenic layer across the E–W-trending velocity boundary between the low- and high-Vp/Vs areas that corresponds well with the Rokkoku Tectonic Line; this geological boundary is the likely cause of the dislocation of the seismogenic layer because it is intruded by serpentinite veins. A possible factor in the southern rupture termination of the 2016 Kumamoto Earthquake is the existence of a high-Vp/Vs body in the direction of southern rupture propagation. The provided details of this inhomogeneous barrier, which are inferred from the seismic velocity structures, may improve future seismic hazard assessments for a complex fault system composed of multiple segments.


Sign in / Sign up

Export Citation Format

Share Document