scholarly journals Short tip–more function? Atrial fibrillation ablation using the novel third-generation cryoballoon in resected pulmonary vein

2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Fabrizio Bologna ◽  
K. R. Julian Chun

Abstract Background Cryoballoon ablation is an established procedure for atrial fibrillation (AF). Patients who had previous pulmonary surgery undergoing pulmonary vein isolation (PVI) were seldom reported. Case presentation We describe an AF ablation using the novel short-tip third-generation cryoballoon in a patient with resected pulmonary vein. All pulmonary veins were successfully isolated without complication. The short-tip third-generation cryoballoon shows advantageous profile in PVI for AF patients with previous pulmonary surgery. Conclusions This report indicates that for AF patient who had previous resected PV surgery, the short-tip CB 3 provides an ideal device option for real-time PVI.

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A P Martin ◽  
M Fowler ◽  
N Lever

Abstract Background Pulmonary vein isolation using cryotherapy is an established treatment for the management of patients with paroxysmal atrial fibrillation. Ablation using the commercially available balloon cryocatheter has been shown to create wide antral pulmonary vein isolation. A novel balloon cryocatheter (BCC) has been designed to maintain uniform pressure and size during ablation, potentially improving contact with the antral anatomy. The extent of ablation created using the novel BCC has not previously been established. Purpose To determine the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing catheter ablation for paroxysmal atrial fibrillation using the novel BCC. Methods Nine consecutive patients underwent pre-procedure computed tomography angiography of the left atrium to quantify the chamber dimensions. An electroanatomical map was created using the cryoablation system mapping catheter and a high definition mapping system. A bipolar voltage map was obtained following ablation to determine the extent of pulmonary vein isolation ablation. A volumetric technique was used to quantify the extent of vein and posterior wall electrical isolation in addition to traditional techniques for proving entrance and exit block. Results All patients had paroxysmal atrial fibrillation, mean age 56 years, 7 (78%) male. Electrical isolation was achieved for 100% of the pulmonary veins; mean total procedure time was 109 min (+/- 26 SD), and fluoroscopy time 14.9 min (+/- 2.4 SD). The median treatment applications per vein was one (range one - four), and median treatment duration 180 sec (range 180 -240). Left atrial volume 32 mL/m2 (+/- 7 SD), and mean left atrial posterior wall area 22 cm2 (+/- 4 SD). Data was available for quantitative assessment of the extent of ablation for eight patients. No lesions (0 of 32) were ostial in nature. The antral surface area of ablation was not statistically different between the left and right sided pulmonary veins (p 0.63), which were 5.9 (1.6 SD) and 5.4 (2.1 SD) cm2 respectively. In total 50% of the posterior left atrial wall was ablated.  Conclusion Pulmonary vein isolation using a novel BCC provides a wide and antral lesion set. There is significant debulking of the posterior wall of the left atrium. Abstract Figure.


2020 ◽  
Vol 2020 (2) ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Shota Tohoku ◽  
K R Julian Chun

Background: Cryoballoon ablation is an established procedure for atrial fibrillation (AF). Patient with vena cava filter undergoing pulmonary vein isolation (PVI) were seldom reported.Case presentation: We describe an AF ablation technique using the second generation cryoballoon in a patient after vena cava filter implantation. All pulmonary veins were successfully isolated without complication.Conclusions: For AF patient with previously implanted vena cava filter, cryoballoon based PVI appears feasible and safe.


2019 ◽  
Vol 7 (4S) ◽  
pp. 6-14
Author(s):  
T. Y. Chichkova ◽  
S. E. Mamchur ◽  
E. A. Khomenko

Aim. To estimate the clinical success of cryoballoon pulmonary vein isolation (PVI).Methods.230 patients (males: 49.6%, mean age 57 (53; 62) with symptomatic paroxysmal and persistent atrial fibrillation (AF) resistant to antiarrhythmic therapy were included in a single-center prospective study. The patients were randomized into 2 groups to undergo either cryoballoon ablation (n = 122) or radiofrequency (RF) (n = 108) ablation. Both groups were comparable in baseline parameters. The follow-up period was 12 months. Clinical outcomes were estimated with the use of a three-stage scale. The rates of cardiovascular rehospitalizations, direct-current cardioversions and repeated ablations during were estimated within the follow-up. The quality of life (QoL) in the cryoablation group was measured using the AFEQT scale.Results.77% (n = 94) of patients in the cryoballoon ablation group and 71.3% (n = 77) of patients in the RF group (р = 0.71) demonstrated reported the optimal clinical effects. Both groups, cryo ablation and RF ablation, had similar rates of cardiovascular hospitalizations (23.8 vs 28.7%, OR 0.8, 95% CI 0.4–1.4; р = 0.39), direct-current cardioversions (12.3 vs 17.6%, OR 0.7, 95% CI 0.3–1.4; р = 0.26) and repeated ablations (9.8–11.1%, OR 0.9, 95% CI 0.4–2.0; р = 0.75). The patients treated with cryoballoon as opposed to RF ablation had significantly more successful usage of “pill-in-pocket” strategy – 14.8 vs 6.5% (OR 2.5, 95% CI 1.01–6.2; р = 0.04). Significant improvements of the QoL parameters with strong size effect have been found in the cryoablation group, i.e. global score (GS) increased by 8.9±6.9 (95% CI 6.6–10.1; dCohen 1.2; р<0.001), symptoms (S) – by 8.3±7.9 (95% CI 4.2–8.8; dCohen 1.5; р<0.001), daily activities (DA) – by 10.0±6.9 (95% CI = 6.4–10.6; dCohen 0.9; р<0.001), treatment concerns (TC) – by 5.5±6.0 (95% CI 6.3–9.2; dCohen 1.2; р<0.001) and treatment satisfaction (TS) – by 5.5±6.0 (95% CI 5.4–9.8; dCohen 0.9; р<0.001).Conclusion.The both catheter-based technologies had comparable clinical success. Cryoablation was characterized by improvement in all QoL parameters based on the AFEQT score.


Heart Rhythm ◽  
2016 ◽  
Vol 13 (2) ◽  
pp. 424-432 ◽  
Author(s):  
Arash Aryana ◽  
Giacomo Mugnai ◽  
Sheldon M. Singh ◽  
Deep K. Pujara ◽  
Carlo de Asmundis ◽  
...  

EP Europace ◽  
2016 ◽  
Vol 18 (suppl_1) ◽  
pp. i169-i169 ◽  
Author(s):  
Alexander Fürnkranz ◽  
Bordignon Stefano ◽  
Daniela Dugo ◽  
Perotta Laura ◽  
Fabrizio Bologna ◽  
...  

Author(s):  
Filip Casselman ◽  
Ihsan Bakir ◽  
Pedro Brugada ◽  
Peter Geelen ◽  
Francis Wellens ◽  
...  

Objective To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. Methods Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ±31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. Results The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. Conclusions Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.


Sign in / Sign up

Export Citation Format

Share Document