P1415Wide antral circumferential pulmonary vein isolation ablation using a novel balloon cryoablation catheter

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A P Martin ◽  
M Fowler ◽  
N Lever

Abstract Background Pulmonary vein isolation using cryotherapy is an established treatment for the management of patients with paroxysmal atrial fibrillation. Ablation using the commercially available balloon cryocatheter has been shown to create wide antral pulmonary vein isolation. A novel balloon cryocatheter (BCC) has been designed to maintain uniform pressure and size during ablation, potentially improving contact with the antral anatomy. The extent of ablation created using the novel BCC has not previously been established. Purpose To determine the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing catheter ablation for paroxysmal atrial fibrillation using the novel BCC. Methods Nine consecutive patients underwent pre-procedure computed tomography angiography of the left atrium to quantify the chamber dimensions. An electroanatomical map was created using the cryoablation system mapping catheter and a high definition mapping system. A bipolar voltage map was obtained following ablation to determine the extent of pulmonary vein isolation ablation. A volumetric technique was used to quantify the extent of vein and posterior wall electrical isolation in addition to traditional techniques for proving entrance and exit block. Results All patients had paroxysmal atrial fibrillation, mean age 56 years, 7 (78%) male. Electrical isolation was achieved for 100% of the pulmonary veins; mean total procedure time was 109 min (+/- 26 SD), and fluoroscopy time 14.9 min (+/- 2.4 SD). The median treatment applications per vein was one (range one - four), and median treatment duration 180 sec (range 180 -240). Left atrial volume 32 mL/m2 (+/- 7 SD), and mean left atrial posterior wall area 22 cm2 (+/- 4 SD). Data was available for quantitative assessment of the extent of ablation for eight patients. No lesions (0 of 32) were ostial in nature. The antral surface area of ablation was not statistically different between the left and right sided pulmonary veins (p 0.63), which were 5.9 (1.6 SD) and 5.4 (2.1 SD) cm2 respectively. In total 50% of the posterior left atrial wall was ablated.  Conclusion Pulmonary vein isolation using a novel BCC provides a wide and antral lesion set. There is significant debulking of the posterior wall of the left atrium. Abstract Figure.

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S127-S128
Author(s):  
Leonid Garber ◽  
Lior Jankelson ◽  
Eric H. Shulman ◽  
Roi Bar-Cohen ◽  
Connor Peterson ◽  
...  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D Blendea ◽  
S Istratoaie ◽  
S Pop ◽  
M Mansour

Abstract Introduction The effect of circumferential pulmonary vein isolation (PVI) for atrial fibrillation (AF) on left atrial (LA) function has not been well defined. Purpose The aim of this study was to evaluate the immediate impact of ablation on parameters of global and regional LA function using intracardiac echocardiography (ICE) Methods We studied 26 consecutive patients (age 56±10 years, 19 men) with paroxysmal AF using ICE before and immediately after circumferential PVI. All pulmonary veins were isolated in all patients. ICE measurements included LA fractional area shortening, peak A wave on transmitral Doppler flow, peak emptying velocity on the left atrial appendage (LAA) Doppler flow, as well as tissue Doppler myocardial velocities at the level of the posterior LA wall, interatrial septum, and lateral wall, which were used as parameters of regional LA function. Results The mean radiofrequency ablation time was 37±22min. Post ablation there was a significant reduction of the LA fractional area shortening from 27±8% to 22±6% (p<0.01). The tissue Doppler velocity of atrial contraction at the posterior wall decreased significantly post ablation: from 8.9±1.8 cm/s to 6.9±1.4 cm/s (p<0.01). There were no significant differences between the pre and post ablation values for tissue Doppler velocities at the level of the interatrial septum or LA lateral wall. The post ablation peak transmitral A wave and peak LAA Doppler velocities did not differ significantly from the pre ablation values. Conclusion In patients with paroxysmal atrial fibrillation, circumferential PVI results in an immediate decrease in LA function without a significant change in LAA function.


Author(s):  
Filip Casselman ◽  
Ihsan Bakir ◽  
Pedro Brugada ◽  
Peter Geelen ◽  
Francis Wellens ◽  
...  

Objective To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. Methods Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ±31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. Results The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. Conclusions Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.


2021 ◽  
pp. 52-55
Author(s):  
Adi Lador ◽  
Miguel Valderrábano

Catheter ablation has become a cornerstone treatment for atrial fibrillation (AF). Pulmonary vein isolation is the accepted approach for paroxysmal AF ablation, but it is less effective for persistent AF. The vein of Marshall (VOM) is located in the epicardial left atrium and can be a source of AF triggers as well as a tract for autonomic nerves. It directly communicates with the underlying myocardium, including the left atrial ridge and the posterior mitral isthmus. This review discusses the latest evidence regarding the mechanisms, procedural aspects, and outcomes of VOM ethanol infusion when used as an adjunct to pulmonary vein isolation in patients with persistent AF.


Author(s):  
Sapan Bhuta ◽  
Gustaf Sverin ◽  
Hiro Kawata ◽  
Malek Bashti ◽  
Jessica Hunter ◽  
...  

Background: Previous studies suggest that wide area circumferential pulmonary vein ablation (WACA) is more effective than segmental pulmonary vein ablation (SPVA) for pulmonary vein isolation (PVI) for treatment of atrial fibrillation. Whether this is true in patients (pts) with very short duration paroxysmal atrial fibrillation (PAF) is unknown. Objective: To compare WACA to SPVA in pts with PAF lasting <48 hours. Methods: One hundred pts with PAF <48 hours were randomized to either WACA vs SPVA (45 and 53 pts respectively, with 2 withdrawals), and followed up for 24 months with 14-day ECGs every 6 months. Results: Among 97 pts at an average of 22.1±4.8 months followup, 26 (57.8%) remained free of any atrial arrhythmias after WACA versus 29 (55.86%) after SPVA (p=0.64). Sixteen pts (35.6%) had recurrent PAF after WACA versus 20 pts (38.5%) after SPVA (p=0.79). Seven pts (15.6%) had atrial flutter after WACA versus 5 pts (9.64%) after SPVA (p=0.376) and 1 pt (2.2%) had atrial tachycardia after WACA vs 1 pt (1.9%) after SPVA (p=0.918). Total procedure time was lower for SPVA vs WACA (242.9 vs 271.1 minutes, p= 0.047), and fluoroscopy time similar for WACA vs SPVA (50.8 vs 53.4 minutes, p=0.555). Conclusions: As an initial ablation approach in pts with PAF <48 hours, SPVA was similarly effective to WACA with respect to arrhythmia recurrence, supporting the central role of the pulmonary veins for maintaining AF in these pts. Future therapies using alternative ablation energies may incorporate these insights to reduce risk to gastroesophageal structures.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Fabrizio Bologna ◽  
K. R. Julian Chun

Abstract Background Cryoballoon ablation is an established procedure for atrial fibrillation (AF). Patients who had previous pulmonary surgery undergoing pulmonary vein isolation (PVI) were seldom reported. Case presentation We describe an AF ablation using the novel short-tip third-generation cryoballoon in a patient with resected pulmonary vein. All pulmonary veins were successfully isolated without complication. The short-tip third-generation cryoballoon shows advantageous profile in PVI for AF patients with previous pulmonary surgery. Conclusions This report indicates that for AF patient who had previous resected PV surgery, the short-tip CB 3 provides an ideal device option for real-time PVI.


Sign in / Sign up

Export Citation Format

Share Document