1981 ◽  
Vol 53 (4) ◽  
pp. 752-752
Author(s):  
S Farwell ◽  
D Liebowitz ◽  
R Kagel ◽  
D Adams
Keyword(s):  

Author(s):  
Hellen S. Santos ◽  
Karine L. Buarque da Silva ◽  
Ariel E. Zanini ◽  
Danilo S. Coelho ◽  
Marcelo Embiruçu ◽  
...  

Background: Brazilian bentonites have a low sodium concentration in their interlayer structure. This is a problem with most of the industrial applications that demand the characteristics of sodium bentonites. Objective: As a solution for this limitation, sodium carbonate is added to in natura clays, promoting ion exchange between other interlayer cations with sodium. Methods: A process was used based on the principle of Stokes’ Law (BR Patent 10 2013 016298). For this, we used four glass columns in series, in which a high water flow was considered to obtain purified clays. It was proposed as a simple, fast and economical method for sodium determination that was developed and applied in bentonites by flame photometry. The equipment calibration was performed with a NaCl standard solution in concentrations between 80 and 110 ppm. The bentonites in the suspension were separated by means of centrifugation, being thus analyzed by a flame photometer. Results: The samples were prepared according to the manufacturer’s specifications to contain detectable amounts of sodium by means of flame photometry. A resulting linear relationship between the average value readings versus sodium standard content solution (both in ppm) was obtained by the logarithmic scale, as expected. Conclusion: The procedure allowed to define a method that could be used in the sodification control process, thus making it possible to differentiate the sodium cation content in terms of the value of cation exchange capacity (CEC) from bentonite. X-ray analysis of in natura and the sodified clays showed nanostructural differences related to interlayer distance.


1956 ◽  
Vol 219 (2) ◽  
pp. 885-892
Author(s):  
Sidney Davis ◽  
T.H. Simpson

1961 ◽  
Vol 33 (12) ◽  
pp. 1727-1732 ◽  
Author(s):  
J. D. Winefordner ◽  
H. W. Latz

1959 ◽  
Vol 31 (12) ◽  
pp. 2033-2036 ◽  
Author(s):  
W. H. Foster ◽  
D. N. Hume

2015 ◽  
Vol 8 (1) ◽  
pp. 25 ◽  
Author(s):  
Hiu Tung Chu ◽  
Spencer E. Taylor

<p>The routine determination of some group 1 and group 2 metals is important because of their biological, physiological and industrial relevance. Flame atomic emission spectrometry, or flame photometry (FP), is well-suited to the determination of several alkali and alkaline earth metals which are easily ionized in a gas flame. Here, we consider the application of flame photometry as a simple but sensitive analytical method which is normally restricted to the determination of one element at a time. We have demonstrated the use of a new multi-element instrument for the simultaneous determination of four cations, namely Li<sup>+</sup>, Na<sup>+</sup>, K<sup>+</sup> and Ca<sup>2+</sup> in six different brands of soy sauce currently available in the UK. The Na<sup>+</sup> concentrations are compared with quoted nutrition values given on the product labels, and found to be in very good agreement for “low-salt” soy sauce, but some departures were noted in the higher salt products, the present results indicating higher salt content than the supplied data. Li<sup>+</sup> concentrations were below the detection limit (i.e., &lt;1 mg/L under the conditions used in this study). This demonstration study has shown multi-element flame photometry to be a straightforward means of analysing water-based products that could be more widely adopted for many different applications. Typical maximum concentrations for the direct analysis of aqueous solutions were found to be 50 mg/L (Li<sup>+</sup>), 200 mg/L (Na<sup>+</sup>, K<sup>+</sup>) and 1000 mg/L (Ca<sup>2+)</sup>. Although not the primary goal of this study, we noted some variance between the present results and values quoted on some of the products. This may relate to the use of indirect methods for estimating salt (sodium) concentrations. The use of flame photometry, however, would provide a rapid measurement of important cations in a wide range of applications.</p>


1990 ◽  
Vol 100 (1-2) ◽  
pp. 1-6 ◽  
Author(s):  
Xun -Yun Sun ◽  
Walter A. Aue

Sign in / Sign up

Export Citation Format

Share Document