crease the proportion of machine sources in the near future. If radiation process­ ing continues to grow, the shortage of Co, which has caused some delays in deliveries in the past, will become more acute. This also points to an increasingly important role for electron accelerators. Generalizing conclusions about the relative economics of different types of irradiation may be misleading because the relative costs of different radiation facilities are considerably affected by local conditions such as costs of electricity, labor, transportation, and construction. The economics of operation also depends on the use level of a facility. Where operations can be continued day and night for months a year a radionuclide source may be more economic, however, where intermittent operations are more likely a machine source may be more advanta­ geous. Sociopolitical considerations relate to the observation that in some countries it is getting more and more difficult to overcome local opposition to the installation of new radioisotope sources. Fears for the safety of the environment in shipping and storing large inventories of 60Co or 137Cs are often cited as the main reason for this opposition. Regardless of whether these fears are justified, planners cannot disregard them. As an example, the National Food Processors Association (NFPA), with support from the U.S. Department of Energy, negotiated in the summer of 1985 for a site in Dublin, California, to build a demonstration and training facility for food irradiation, using 3 million Ci of ,Cs. The opposition

1995 ◽  
pp. 45-45
2018 ◽  
Vol 61 (2) ◽  
pp. 331-340 ◽  
Author(s):  
Daniela Sofia Jones ◽  
Stephen W. Searcy ◽  
Laurence M. Eaton

Abstract. The U.S. Department of Energy (DOE) has estimated herbaceous biomass availability through simulations with the Policy Analysis System (POLYSYS) agricultural modeling framework. An operational assumption for POLYSYS limited conversion of pastureland to perennial grass crops to counties east of the 100th meridian as a proxy for precipitation sufficient for economically viable yield, but allowed cropland conversion regardless of location. Knowledge of local conditions raised questions about predicted biomass quantities for Texas counties in the 2011 assessment. POLYSYS was rerun with different assumptions, specifically replacing the 100th meridian boundary with annual average precipitation data and limiting cropland conversion in low-rainfall counties. Perennial grass production was found to be overestimated by 8% and 87% in the U.S. and Texas, respectively (at $66.14 DMg-1), when limiting all land conversion to regions with >635 mm precipitation. Total herbaceous biomass predicted was approximately the same as in the BT2, but the biomass geographical location changed across the nation. Texas’ biomass contribution decreased from 6% to 1% at $66.14 DMg-1 and from 16% to 11% at $88.18 DMg-1. Subsequent to this research being conducted, the DOE released the 2016 biomass inventory assessment, and these results are compared to those newest estimates. Keywords: Billion-Ton Study, Biomass, Perennial grass, Precipitation, Switchgrass.


1982 ◽  
Vol 14 (12) ◽  
pp. 45-59 ◽  
Author(s):  
R L Jolley ◽  
R B Cumming ◽  
N E Lee ◽  
J E Thompson ◽  
L R Lewis

The principal objective of this research program was to examine the effects of disinfection by chlorine, ozone, and ultraviolet light (uv) irradiation on nonvolatile organic constituents relative to chemical effects and the formation of micropollutants. In a comparative study of highly concentrated samples of effluents from nine wastewater treatment plants, it was determined that disinfection with chlorine or ozone both destroys and produces nonvolatile organic constituents including mutagenic constituents. The chemical effects of disinfection by uv irradiation were relatively slight, although the mutagenic constituents in one effluent were eliminated by this treatment. The nine wastewater treatment plants were selected by using the following criteria: disinfection method, nature of wastewater source, type of wastewater treatment, standards for quality of treatment, and geographical location. The treatment plants varied from pilot plant and small plants [0.05 m3/s (1 Mgd)] treating principally domestic waste to large plants [4.4 m3/s (100 Mgd)] treating principally industrial waste. Four plants used only chlorine for disinfection, four used ozone for disinfection, and one used uv irradiation for disinfection. Eight treatment plants used conventional secondary or more advanced wastewater treatment, and one plant used primary treatment. The following methodology was used in this investigation: grab sample collection of 40-L samples of undisinfected and disinfected effluents; concentration of the effluents by lyophilization; high-pressure liquid chromatographic separation of nonvolatile organic constituents in effluent concentrates using uv absorbance, cerate oxidation, and fluorescence detectors; bacterial mutagenicity testing of concentrates and chromatographic fractions; and identification and characterization of nonvolatile organic constituents in mutagenic HPLC fractions. With these procedures, over 100 micropollutants were identified in the wastewater effluent concentrates. Interplant comparison revealed considerable variability in the presence of mutagenic nonvolatile organic constituents in the undisinfected effluent concentrates as well as much variability in the destruction of the mutagenic constituents and the formation of other mutagenic constituents as a result of disinfection. Moreover, the effects varied on samples collected at the same wastewater treatment plant at different periods. No micropollutants known to be mutagens were identified in the mutagenic HPLC fractions separated from the undisinfected, chlorinated, and ozonated effluent concentrates. The mutagenic activity of the nonvolatile organic constituents in one chlorinated effluent concentrate was not attributable to organic chloramines. Most of the mutagens detected in effluent concentrates are direct acting and do not require metabolic activation. Both base-pair substitution mutagens and frame-shift mutagens occurred in the wastewater concentrates, but the former type was more frequent. For many of the compounds in effluents, strain TA-1535 was more sensitive than strain TA-100 in detecting base-pair substitution mutagens. *Research sponsored by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The work was carried out at the Oak Ridge National Laboratory, which is operated by the U.S. Department of Energy under contract W-7405-eng-26 with the Union Carbide Corporation.


Recycling ◽  
2021 ◽  
Vol 6 (2) ◽  
pp. 31
Author(s):  
Linda Gaines ◽  
Qiang Dai ◽  
John T. Vaughey ◽  
Samuel Gillard

The expected rapid growth in electric vehicle deployment will inevitably be followed by a corresponding rise in the supply of end-of-life vehicles and their lithium-ion batteries (LIBs). The batteries may be reused, but will eventually be spent and provide a potential domestic resource that can help supply materials for future battery production. However, commercial recycling processes depend on profits from recovery of cobalt, use of which is being reduced in new cathode chemistries. The U.S. Department of Energy, therefore, established the ReCell Center in early 2019 to develop robust LIB recycling technology that would be economical even for batteries that contain no cobalt. The central feature of the technology is recovery of the cathode material with its unique crystalline cathode morphology intact in order to retain its value and functionality. Other materials are recovered as well in order to maximize revenues and minimize waste-handling costs. Analysis and modeling serve to evaluate and compare process options so that we can identify those that will be most economical while still minimizing energy use and environmental impacts. This paper provides background and describes highlights of the center’s first 2 years of operation.


1996 ◽  
Vol 465 ◽  
Author(s):  
R. D. Rogers ◽  
M. A. Hamilton ◽  
L. O. Nelson ◽  
J. Benson ◽  
M. Green

ABSTRACTBecause there are literally square kilometers of radioactively contaminated concrete surfaces within the U.S. Department of Energy (DOE) complex, the task (both scope and cost) of decontamination is staggering. Complex-wide cleanup using conventional methodology does not appear to be feasible for every facility because of prioritization, cost, and manual effort required.We are investigating the feasibility of using microbially influenced degradation (MID) of concrete as a unique, innovative approach for the decontamination of concrete. Currently, work is being conducted to determine the practicality and cost effectiveness of using this environmentally acceptable method for decontamination of large surface concrete structures. Under laboratory conditions, the biodecontamination process has successfully been used to remove 2 mm of the surface of concrete slabs. Subsequently, initial field application data from an ongoing pilot-scale demonstration have shown that an average of 2 mm of surface can be removed from meter-square areas of contaminated concrete. The cost for the process has been estimated as $1.29/m2. Methodologies for field application of the process are being developed and will be tested. This paper provides information on the MID process, laboratory evaluation of its use for decontamination, and results from the pilot field application.


Sign in / Sign up

Export Citation Format

Share Document