An indentation depth—force sensing wheeled probe for abnormality identification during minimally invasive surgery

Author(s):  
H Liu ◽  
P Puangmali ◽  
D Zbyszewski ◽  
O Elhage ◽  
P Dasgupta ◽  
...  
2017 ◽  
Vol 22 (4) ◽  
pp. 1717-1727 ◽  
Author(s):  
Uikyum Kim ◽  
Dong-Hyuk Lee ◽  
Yong Bum Kim ◽  
Dong-Yeop Seok ◽  
Jinho So ◽  
...  

2022 ◽  
Vol 8 ◽  
Author(s):  
Wael Othman ◽  
Zhi-Han A. Lai ◽  
Carlos Abril ◽  
Juan S. Barajas-Gamboa ◽  
Ricard Corcelles ◽  
...  

As opposed to open surgery procedures, minimally invasive surgery (MIS) utilizes small skin incisions to insert a camera and surgical instruments. MIS has numerous advantages such as reduced postoperative pain, shorter hospital stay, faster recovery time, and reduced learning curve for surgical trainees. MIS comprises surgical approaches, including laparoscopic surgery, endoscopic surgery, and robotic-assisted surgery. Despite the advantages that MIS provides to patients and surgeons, it remains limited by the lost sense of touch due to the indirect contact with tissues under operation, especially in robotic-assisted surgery. Surgeons, without haptic feedback, could unintentionally apply excessive forces that may cause tissue damage. Therefore, incorporating tactile sensation into MIS tools has become an interesting research topic. Designing, fabricating, and integrating force sensors onto different locations on the surgical tools are currently under development by several companies and research groups. In this context, electrical force sensing modality, including piezoelectric, resistive, and capacitive sensors, is the most conventionally considered approach to measure the grasping force, manipulation force, torque, and tissue compliance. For instance, piezoelectric sensors exhibit high sensitivity and accuracy, but the drawbacks of thermal sensitivity and the inability to detect static loads constrain their adoption in MIS tools. Optical-based tactile sensing is another conventional approach that facilitates electrically passive force sensing compatible with magnetic resonance imaging. Estimations of applied loadings are calculated from the induced changes in the intensity, wavelength, or phase of light transmitted through optical fibers. Nonetheless, new emerging technologies are also evoking a high potential of contributions to the field of smart surgical tools. The recent development of flexible, highly sensitive tactile microfluidic-based sensors has become an emerging field in tactile sensing, which contributed to wearable electronics and smart-skin applications. Another emerging technology is imaging-based tactile sensing that achieved superior multi-axial force measurements by implementing image sensors with high pixel densities and frame rates to track visual changes on a sensing surface. This article aims to review the literature on MIS tactile sensing technologies in terms of working principles, design requirements, and specifications. Moreover, this work highlights and discusses the promising potential of a few emerging technologies towards establishing low-cost, high-performance MIS force sensing.


Author(s):  
A L Trejos ◽  
R V Patel ◽  
M D Naish

The reduced access conditions of minimally invasive surgery and therapy (MIST) impair or completely eliminate the feel of tool—tissue interaction forces. Many researchers have been working actively on the development of force sensors and sensing techniques to address this problem. The goal of this survey article is to summarize the state of the art in force sensing techniques for medical interventions in order to identify existing limitations and future directions. A literature search was performed from January to July 2009 using a combination of keywords relevant to the area, including force, sensor, sensing, haptics, and minimally invasive surgery. The literature search resulted in 126 articles with valuable content. This article presents a summary of the force sensing technologies, design specifications for force sensors in clinical applications, force sensors and sensing instruments that have been developed for MIST, and the experiments performed to determine the need for force information. Open areas of research include force sensor design, development of alternative methods of sensing, assessment of the impact of force information on performance, determination of the benefits of haptic information, and evaluation of the human factors involved in the processing and use of force information.


2017 ◽  
Vol 17 (13) ◽  
pp. 3983-3993 ◽  
Author(s):  
Ana Luisa Trejos ◽  
Abelardo Escoto ◽  
Michael D. Naish ◽  
Rajni V. Patel

2004 ◽  
Vol 171 (4S) ◽  
pp. 448-448
Author(s):  
Farjaad M. Siddiq ◽  
Patrick Villicana ◽  
Raymond J. Leveillee

Sign in / Sign up

Export Citation Format

Share Document