scholarly journals Studies on Hydroxyfluoran and Its Derivatives as Organic Reagents. XII. : Determination of I- and NO2- with 3, 4, 5, 6-Tetrachloro-3', 4', 5', 6'-tetrahydroxyfluoran Methyl Ester

1970 ◽  
Vol 90 (7) ◽  
pp. 908-912 ◽  
Author(s):  
ITSUO MORI
1993 ◽  
Vol 58 (8) ◽  
pp. 1821-1831 ◽  
Author(s):  
Jaroslav Jambor ◽  
Tomáš Javorek

The macrophorous hydrophobic sorbent Amberlite XAD-2 proved to be well suited to the preconcentration of minority amounts of Al, Au, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sn, Ti and V in the form of their chelates with organic reagents. From among 14 reagents tested, 8-hydroxyquinoline and diethyldithiocarbamate appeared most suitable for the quantitative sorption up to level of 1 μg l-1 of analyte. Emission spectrometry served as the analytical finish; the nitrous oxide-acetylene flame, electric arc and inductively coupled argon plasma were chosen according to the nature of the element. The procedure is convenient for the determination of the minority analytes in waters


2016 ◽  
Vol 52 (2) ◽  
pp. 85-94
Author(s):  
Barbara Potocka-Banaś ◽  
Krzysztof Borowiak ◽  
Tomasz Janus ◽  
Teresa Dembińska ◽  
Alicja Rak

The aim of the study was to evaluate the usefulness of liquid chromatography-tandem mass spectrometry for determination of cocaine and its metabolites (benzoylecgonine, ecgonine methyl ester) in biological material. Method. Cocaine and its metabolites were quantified using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). Results. The extraction repeated twice with smaller portions of solvent showed higher efficiency and lower values of standard deviation that is why it was applied to further analysis. To increase sensitivity of LC/MS/MS method optimization of declustering potential was performed over 0-300V range and DP=100V was chosen. Collision energy for cocaine and benzoylecgonine was 25V and for ecgonine methyl ester was 22V. High resolution of the apparatus allowed to select narrow signal range for each compound: 185,135±0.025 Da for cocaine-d3, 182,120±0.025 Da for cocaine, 168,105±0.025 Da for benzoylecgonine and 182,125±0.025 Da for ecgonine methyl ester. Results obtained from analysis of two series of cocaine, benzoylecgonine and ecgonine methyl ester samples allowed to plot calibration curves within the range of 1-100 ng/ml which showed linearity. Conclusion. Obtained results allowed for identification and quantitative determination of cocaine and its metabolites (benzoylecgonine and ecgonine methyl ester) in human serum. Liquid chromatography-tandem mass spectrometry can find application in both forensic and clinical toxicology.


Sign in / Sign up

Export Citation Format

Share Document