Rating of perceived exertion and heart rate as indicators of exercise intensity in different environmental temperatures

1994 ◽  
Vol 26 (6) ◽  
pp. 791-796 ◽  
Author(s):  
JEFFREY A. POTTEIGER ◽  
STEVEN F. WEBER
2002 ◽  
Vol 95 (3_suppl) ◽  
pp. 1047-1062 ◽  
Author(s):  
Mee-Lee Leung ◽  
Pak-Kwong Chung ◽  
Raymond W. Leung

This study evaluated the validity and reliability of the Chinese-translated (Cantonese) versions of the Borg 6–20 Rating of Perceived Exertion (RPE) scale and the Children's Effort Rating Table (CERT) during continuous incremental cycle ergometry with 10- to 11-yr.-old Hong Kong school children. A total of 69 children were randomly assigned, with the restriction of groups being approximately equal, to two groups using the two scales, CERT ( n = 35) and RPE ( n = 34). Both groups performed two trials of identical incremental continuous cycling exercise (Trials 1 and 2) 1 wk. apart for the reliability test. Objective measures of exercise intensity (heart rate, absolute power output, and relative oxygen consumption) and the two subjective measures of effort were obtained during the exercise. For both groups, significant Pearson correlations were found for perceived effort ratings correlated with heart rate ( rs ≥ .69), power output ( rs ≥ .75), and oxygen consumption ( rs ≥ .69). In addition, correlations for CERT were consistently higher than those for RPE. High test-retest intraclass correlations were found for both the effort ( R = .96) and perceived exertion ( R = 89) groups, indicating that the scales were reliable. In conclusion, the CERT and RPE scales, when translated into Cantonese, are valid and reliable measures of exercise intensity during controlled exercise by children. The Effort rating may be better than the Perceived Exertion scale as a measure of perceived exertion that can be more validly and reliably used with Hong Kong children.


Author(s):  
Rui Canário-Lemos ◽  
José Vilaça-Alves ◽  
Tiago Moreira ◽  
Rafael Peixoto ◽  
Nuno Garrido ◽  
...  

Indoor cycling’s popularity is related to the combination of music and exercise leading to higher levels of exercise intensity. It was our objective to determine the efficacy of heart rate and rating of perceived exertion in controlling the intensity of indoor cycling classes and to quantify their association with oxygen uptake. Twelve experienced males performed three indoor cycling sessions of 45 min that differed in the way the intensity was controlled: (i) oxygen uptake; (ii) heart rate; and (iii) rating of perceived exertion using the OMNI-Cycling. The oxygen uptake levels were significantly higher (p = 0.007; μp2 = 0.254) in oxygen uptake than heart rate sessions. Oxygen uptake related to body mass was significantly higher (p < 0.005) in the oxygen uptake sessions compared with other sessions. Strong correlations were observed between oxygen uptake mean in the oxygen uptake and rating of perceived exertion sessions (r =0.986, p < 0.0001) and between oxygen uptake mean in the oxygen uptake and heart rate sessions (r = 0.977, p < 0.0001). Both heart rate and rating of perceived exertion are effective in controlling the intensity of indoor cycling classes in experienced subjects. However, the use of rating of perceived exertion is easier to use and does not require special instrumentation.


2013 ◽  
Vol 39 (1) ◽  
pp. 93-101 ◽  
Author(s):  
José M. Muyor

Abstract The purpose of the study was: 1) to determine the intensity of an indoor cycling session; 2) to know the correlation between the rating of perceived exertion (RPE) scales (Borg and OMNI) and % heart rate reserve (%HRR) with categories; and 3) to evaluate the validity of RPE scales (Borg and OMNI) with respect to the heart rate (HR) and %HRR. A total of fifty-three subjects, 25 males and 28 females (ages: 28.79 ± 6.04 years; body height: 1.71 ± 0.09 m; body mass: 69.59 ± 13.69 kg) were recruited from a private fitness club. All subjects performed the same predesigned indoor cycling session with a total duration of 50 minutes. During the experimental trial, the HR was recorded every 5 s. The Borg 6-20 RPE and OMNI 0-10 scales were used to assess perceived exertion in each phase. The average HR in the cardiovascular phase was 152.24 ± 14.11 b•min-1, the %HRR was 80.62 ± 7.10; and the overall RPE (Borg and OMNI scales) was 14.94 ± 1.11 and 7.18 ± 0.79 points, respectively. The correlation between an average HR and %HRR with Borg and OMNI scales was lower than r = 0.4 (p < 0.05). The correlation value between the Borg and the OMNI RPE scales was r = 0.82 (p < 0.001). It can be concluded that indoor cycling elicits effort of high intensity which could be inappropriate for some participants. The Borg and OMNI scales showed a low validity to quantify the intensity performed in indoor cycling sessions. It indicates the necessity to control the intensity of effort with other instruments to improve efficacy and decrease the risk of overload in this activity.


Author(s):  
Spiridon Karavatas ◽  
Kamran Tavakol

Borg’s Rating of Perceived Exertion (RPE) is a simple and convenient method of monitoring exercise intensity; however, the correlation between RPE and heart rate (HR) is not always consistent. This pilot study examined the criterion-based validity of RPE versus heart rate. Twelve fasting, healthy African-American volunteers at ages of 21-41 years performed a supervised, 45-minute brisk walk test on a treadmill over three consecutive days. Throughout the test, each subject was asked the RPE every five minutes. The subjects' heart rates were monitored continuously and recorded every minute. The overall correlation coefficient, r, between RPE and HR for all data sets (N=360) was 0.58. The "r" values for males and females were 0.60 and 0.56, respectively. The analysis revealed that the correlation between RPE and HR was not as strong as previously reported, and that gender influenced the correlation. Also, RPE may be safely used to assess the exercise intensity in healthy subjects


Healthcare ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 150
Author(s):  
Guozhong Chai ◽  
Yinghao Wang ◽  
Jianfeng Wu ◽  
Hongchun Yang ◽  
Zhichuan Tang ◽  
...  

A running exhaustion experiment was used to explore the correlations between the time-frequency domain indexes extracted from the surface electromyography (EMG) signals of targeted muscles, heart rate and exercise intensity, and subjective fatigue. The study made further inquiry into the feasibility of reflecting and evaluating the exercise intensity and fatigue effectively during running using physiological indexes, thus providing individualized guidance for running fitness. Twelve healthy men participated in a running exhaustion experiment with an incremental and constant load. The percentage of heart rate reserve (%HRR), mean power frequency (MPF) and root mean square (RMS) from surface EMG (sEMG) signals of the rectus femoris (RF), biceps femoris (BF), tibialis anterior muscle (TA), and the lateral head of gastrocnemius (GAL) were obtained in real-time. The data were processed and analyzed with the rating of perceived exertion (RPE) scale. The experimental results show that the MPF on all the muscles increased with time, but there was no significant correlation between MPF and RPE in both experiments. Additionally, there was no significant correlation between RMS and RPE of GAL and BF, but there was a negative correlation between RMS and RPE of RF. The correlation coefficient was lower in the constant load mode, with the value of only −0.301. The correlation between RMS and RPE of TA was opposite in both experiments. There was a significant linear correlation between %HRR and exercise intensity (r = 0.943). In the experiment, %HRR was significantly correlated with subjective exercise fatigue (r = 0.954). Based on the above results, the MPF and RMS indicators on the four targeted muscles could not conclusively identify fatigue of lower extremities during running. The %HRR could be used to identify exercise intensity and human fatigue during running and could be used as an indicator of recognizing fatigue and exercise intensity in runners.


1992 ◽  
Vol 9 (1) ◽  
pp. 64-73 ◽  
Author(s):  
Leona J. Holland ◽  
Marcel Bouffard ◽  
Denise Wagner

The reliability of oxygen consumption (VO2), heart rate (HR), and rating of perceived exertion (RPE) at three different workloads was examined during an arm cranking exercise task. Nine persons with multiple sclerosis (MS) and confined to a wheelchair each performed two sessions of discontinuous, submaximal aerobic test on an arm ergometer. Comparisons of the test scores and generalizability theory were used to analyze the data. Both HR and VO2 were found to be reliable measures under the conditions used in this study. RPE at the same workloads was found to be rather unreliable. Overall, the use of RPE as an indicator of exercise intensity instead of HR appears to be unjustified by the results of this study. Therefore, practitioners who want a quick and efficient method of measuring exercise intensity should use HR instead of RPE for persons with multiple sclerosis.


Sign in / Sign up

Export Citation Format

Share Document