An Assessment of the Validity and Reliability of Two Perceived Exertion Rating Scales among Hong Kong Children

2002 ◽  
Vol 95 (3_suppl) ◽  
pp. 1047-1062 ◽  
Author(s):  
Mee-Lee Leung ◽  
Pak-Kwong Chung ◽  
Raymond W. Leung

This study evaluated the validity and reliability of the Chinese-translated (Cantonese) versions of the Borg 6–20 Rating of Perceived Exertion (RPE) scale and the Children's Effort Rating Table (CERT) during continuous incremental cycle ergometry with 10- to 11-yr.-old Hong Kong school children. A total of 69 children were randomly assigned, with the restriction of groups being approximately equal, to two groups using the two scales, CERT ( n = 35) and RPE ( n = 34). Both groups performed two trials of identical incremental continuous cycling exercise (Trials 1 and 2) 1 wk. apart for the reliability test. Objective measures of exercise intensity (heart rate, absolute power output, and relative oxygen consumption) and the two subjective measures of effort were obtained during the exercise. For both groups, significant Pearson correlations were found for perceived effort ratings correlated with heart rate ( rs ≥ .69), power output ( rs ≥ .75), and oxygen consumption ( rs ≥ .69). In addition, correlations for CERT were consistently higher than those for RPE. High test-retest intraclass correlations were found for both the effort ( R = .96) and perceived exertion ( R = 89) groups, indicating that the scales were reliable. In conclusion, the CERT and RPE scales, when translated into Cantonese, are valid and reliable measures of exercise intensity during controlled exercise by children. The Effort rating may be better than the Perceived Exertion scale as a measure of perceived exertion that can be more validly and reliably used with Hong Kong children.

1992 ◽  
Vol 9 (1) ◽  
pp. 64-73 ◽  
Author(s):  
Leona J. Holland ◽  
Marcel Bouffard ◽  
Denise Wagner

The reliability of oxygen consumption (VO2), heart rate (HR), and rating of perceived exertion (RPE) at three different workloads was examined during an arm cranking exercise task. Nine persons with multiple sclerosis (MS) and confined to a wheelchair each performed two sessions of discontinuous, submaximal aerobic test on an arm ergometer. Comparisons of the test scores and generalizability theory were used to analyze the data. Both HR and VO2 were found to be reliable measures under the conditions used in this study. RPE at the same workloads was found to be rather unreliable. Overall, the use of RPE as an indicator of exercise intensity instead of HR appears to be unjustified by the results of this study. Therefore, practitioners who want a quick and efficient method of measuring exercise intensity should use HR instead of RPE for persons with multiple sclerosis.


Author(s):  
Claudio Perret ◽  
Kathrin Hartmann

AbstractThe heart rate-based lactate minimum test is a highly reproducible exercise test. However, the relation between lactate minimum determined by this test and maximal lactate steady state in running and cycling is still unclear. Twelve endurance-trained men performed this test in running and cycling. Exercise intensity at maximal lactate steady state was determined by performing several constant heart rate endurance tests for both exercise modes. Heart rate, power output, lactate concentration, oxygen uptake and rating of perceived exertion at lactate minimum, maximal lactate steady state and maximal performance were analysed. All parameters were significantly higher at maximal lactate steady state compared to lactate minimum for running and cycling. Significant correlations (p<0.05) between maximal lactate steady state and lactate minimum data were found. Peak heart rate and peak oxygen uptake were significantly higher for running versus cycling. Nevertheless, the exercise mode had no influence on relative (in percentage of maximal values) heart rate at lactate minimum (p=0.099) in contrast to relative power output (p=0.002). In conclusion, all measured parameters at lactate minimum were significantly lower but highly correlated with values at maximal lactate steady state in running and cycling, which allows to roughly estimate exercise intensity at maximal lactate steady state with one single exercise test.


2016 ◽  
Vol 11 (6) ◽  
pp. 707-714 ◽  
Author(s):  
Benoit Capostagno ◽  
Michael I. Lambert ◽  
Robert P. Lamberts

Finding the optimal balance between high training loads and recovery is a constant challenge for cyclists and their coaches. Monitoring improvements in performance and levels of fatigue is recommended to correctly adjust training to ensure optimal adaptation. However, many performance tests require a maximal or exhaustive effort, which reduces their real-world application. The purpose of this review was to investigate the development and use of submaximal cycling tests that can be used to predict and monitor cycling performance and training status. Twelve studies met the inclusion criteria, and 3 separate submaximal cycling tests were identified from within those 12. Submaximal variables including gross mechanical efficiency, oxygen uptake (VO2), heart rate, lactate, predicted time to exhaustion (pTE), rating of perceived exertion (RPE), power output, and heart-rate recovery (HRR) were the components of the 3 tests. pTE, submaximal power output, RPE, and HRR appear to have the most value for monitoring improvements in performance and indicate a state of fatigue. This literature review shows that several submaximal cycle tests have been developed over the last decade with the aim to predict, monitor, and optimize cycling performance. To be able to conduct a submaximal test on a regular basis, the test needs to be short in duration and as noninvasive as possible. In addition, a test should capture multiple variables and use multivariate analyses to interpret the submaximal outcomes correctly and alter training prescription if needed.


2018 ◽  
Vol 43 (4) ◽  
pp. 397-402 ◽  
Author(s):  
Corinne N. Boyd ◽  
Stephanie M. Lannan ◽  
Micah N. Zuhl ◽  
Ricardo Mora-Rodriguez ◽  
Rachael K. Nelson

While hot yoga has gained enormous popularity in recent years, owing in part to increased environmental challenge associated with exercise in the heat, it is not clear whether hot yoga is more vigorous than thermo-neutral yoga. Therefore, the aim of this study was to determine objective and subjective measures of exercise intensity during constant intensity yoga in a hot and thermo-neutral environment. Using a randomized, crossover design, 14 participants completed 2 identical ∼20-min yoga sessions in a hot (35.3 ± 0.8 °C; humidity: 20.5% ± 1.4%) and thermo-neutral (22.1 ± 0.2 °C; humidity: 27.8% ± 1.6%) environment. Oxygen consumption and heart rate (HR) were recorded as objective measures (percentage of maximal oxygen consumption and percentage of maximal HR (%HRmax)) and rating of perceived exertion (RPE) was recorded as a subjective measure of exercise intensity. There was no difference in exercise intensity based on percentage of maximal oxygen consumption during hot versus thermo-neutral yoga (30.9% ± 2.3% vs. 30.5% ± 1.8%, p = 0.68). However, exercise intensity was significantly higher during hot versus thermo-neutral yoga based on %HRmax (67.0% ± 2.3% vs. 60.8% ± 1.9%, p = 0.01) and RPE (12 ± 1 vs. 11 ± 1, p = 0.04). According to established exercise intensities, hot yoga was classified as light-intensity exercise based on percentage of maximal oxygen consumption but moderate-intensity exercise based on %HRmax and RPE while thermo-neutral yoga was classified as light-intensity exercise based on percentage of maximal oxygen uptake, %HRmax, and RPE. Despite the added hemodynamic stress and perception that yoga is more strenuous in a hot environment, we observed similar oxygen consumption during hot versus thermo-neutral yoga, classifying both exercise modalities as light-intensity exercise.


2020 ◽  
pp. 1-5
Author(s):  
Megan Wagner ◽  
Kevin D. Dames

Context: Bodyweight-supporting treadmills are popular rehabilitation tools for athletes recovering from impact-related injuries because they reduce ground reaction forces during running. However, the overall metabolic demand of a given running speed is also reduced, meaning athletes who return to competition after using such a device in rehabilitation may not be as fit as they had been prior to their injury. Objective: To explore the metabolic effects of adding incline during bodyweight-supported treadmill running. Design: Cross-sectional. Setting: Research laboratory. Participants: Fourteen apparently healthy, recreational runners (6 females and 8 males; 21 [3] y, 1.71 [0.08] m, 63.11 [6.86] kg). Interventions: The participants performed steady-state running trials on a bodyweight-supporting treadmill at 8.5 mph. The control condition was no incline and no bodyweight support. All experimental conditions were at 30% bodyweight support. The participants began the sequence of experimental conditions at 0% incline; this increased to 1%, and from there on, 2% incline increases were introduced until a 15% grade was reached. Repeated-measures analysis of variance was used to compare all bodyweight-support conditions against the control condition. Main Outcome Measures: Oxygen consumption, heart rate, and rating of perceived exertion. Results: Level running with 30% bodyweight support reduced oxygen consumption by 21.6% (P < .001) and heart rate by 12.0% (P < .001) compared with the control. Each 2% increase in incline with bodyweight support increased oxygen consumption by 6.4% and heart rate by 3.2% on average. A 7% incline elicited similar physiological measures as the unsupported, level condition. However, the perceived intensity of this incline with bodyweight support was greater than the unsupported condition (P < .001). Conclusions: Athletes can maintain training intensity while running on a bodyweight-supporting treadmill by introducing incline. Rehabilitation programs should rely on quantitative rather than qualitative data to drive exercise prescription in this modality.


2009 ◽  
Vol 19 (4) ◽  
pp. 400-409 ◽  
Author(s):  
Milou Beelen ◽  
Jort Berghuis ◽  
Ben Bonaparte ◽  
Sam B. Ballak ◽  
Asker E. Jeukendrup ◽  
...  

It has been reported previously that mouth rinsing with a carbohydrate-containing solution can improve cycling performance. The purpose of the current study was to investigate the impact of such a carbohydrate mouth rinse on exercise performance during a simulated time trial in a more practical, postprandial setting. Fourteen male endurance-trained athletes were selected to perform 2 exercise tests in the morning after consuming a standardized breakfast. They performed an ~1-hr time trial on a cycle ergometer while rinsing their mouths with either a 6.4% maltodextrin solution (CHO) or water (PLA) after every 12.5% of the set amount of work. Borg’s rating of perceived exertion (RPE) was assessed after every 25% of the set amount of work, and power output and heart rate were recorded continuously throughout the test. Performance time did not differ between treatments and averaged 68.14 ± 1.14 and 67.52 ± 1.00 min in CHO and PLA, respectively (p = .57). In accordance, average power output (265 ± 5 vs. 266 ± 5 W, p = .58), heart rate (169 ± 2 vs. 168 ± 2 beats/min, p = .43), and RPE (16.4 ± 0.3 vs. 16.7 ± 0.3 W, p = .26) did not differ between treatments. Furthermore, after dividing the trial into 8s, no differences in power output, heart rate, or perceived exertion were observed over time between treatments. Carbohydrate mouth rinsing does not improve time-trial performance when exercise is performed in a practical, postprandial setting.


2008 ◽  
Vol 16 (1) ◽  
pp. 14-23 ◽  
Author(s):  
David R. Dolbow ◽  
Richard S. Farley ◽  
Jwa K. Kim ◽  
Jennifer L. Caputo

The purpose of this study was to examine the cardiovascular responses to water treadmill walking at 2.0 mph (3.2 km/hr), 2.5 mph (4.0 km/hr), and 3.0 mph (4.8 km/hr) in older adults. Responses to water treadmill walking in 92 °F (33 °C) water were compared with responses to land treadmill walking at 70 °F (21 °C) ambient temperature. After an accommodation period, participants performed 5-min bouts of walking at each speed on 2 occasions. Oxygen consumption (VO2), heart rate (HR), systolic blood pressure (SBP), and rating of perceived exertion (RPE) were significantly higher during therapeutic water treadmill walking than during land treadmill walking. Furthermore, VO2, HR, and RPE measures significantly increased with each speed increase during both land and water treadmill walking. SBP significantly increased with each speed during water treadmill walking but not land treadmill walking. Thus, it is imperative to monitor HR and blood pressure for safety during this mode of activity for older adults.


2020 ◽  
Vol 5 (1) ◽  
pp. 15 ◽  
Author(s):  
Andrea Fusco ◽  
William Sustercich ◽  
Keegan Edgerton ◽  
Cristina Cortis ◽  
Salvador J. Jaime ◽  
...  

Rating of perceived exertion (RPE) and session RPE (sRPE) are reliable tools for predicting exercise intensity and are alternatives to more technological and physiological measurements, such as blood lactate (HLa) concentration, oxygen consumption and heart rate (HR). As sRPE may also convey some insights into accumulated fatigue, the purpose of this study was to examine the effects of progressive fatigue in response to heavier-than-normal training on sRPE, with absolute training intensity held constant, and determine its validity as marker of fatigue. Twelve young adults performed eight interval workouts over a two-week period. The percentage of maximal HR (%HRmax), HLa, RPE and sRPE were measured for each session. The HLa/RPE ratio was calculated as an index of fatigue. Multilevel regression analysis showed significant differences for %HRmax (p = 0.004), HLa concentration (p = 0.0001), RPE (p < 0.0001), HLa/RPE ratio (p = 0.0002) and sRPE (p < 0.0001) across sessions. Non-linear regression analysis revealed a very large negative relationship between HLa/RPE ratio and sRPE (r = −0.70, p < 0.0001). These results support the hypothesis that sRPE is a sensitive tool that provides information on accumulated fatigue, in addition to training intensity. Exercise scientists without access to HLa measurements may now be able to gain insights into accumulated fatigue during periods of increased training by using sRPE.


Sign in / Sign up

Export Citation Format

Share Document