scholarly journals Development Of A Dxa-derived Body Volume Equation In Hispanic Adults For Administering In 4-compartment Models

2020 ◽  
Vol 52 (7S) ◽  
pp. 876-876
Author(s):  
Brett S. Nickerson ◽  
Kyung-Shin Park ◽  
Michael V. Fedewa ◽  
Cherilyn N. McLester ◽  
John R. McLester ◽  
...  
2020 ◽  
Vol 123 (12) ◽  
pp. 1373-1381 ◽  
Author(s):  
Brett S. Nickerson ◽  
Michael V. Fedewa ◽  
Cherilyn N. McLester ◽  
John R. McLester ◽  
Michael R. Esco

AbstractThe purpose of the present study was: (1) to develop a new dual-energy X-ray absorptiometry (DXA)-derived body volume (BV) equation with the GE-Lunar prodigy while utilising underwater weighing (UWW) as a criterion and (2) to cross-validate the novel DXA-derived BV equation (4C-DXANickerson), Wilson DXA-derived BV equation (4C-DXAWilson) and air displacement plethysmography (ADP)-derived BV (4C-ADP) in Hispanic adults. A total of 191 Hispanic adults (18–45 years) participated in the present study. The development sample consisted of 120 females and males (50 % females), whereas the cross-validation sample comprised of forty-one females and thirty males (n 71). Criterion body fat percentage (BF %) and fat-free mass (FFM) were determined using a four-compartment (4C) model with UWW as a criterion for BV (4C-UWW). 4C-DXANickerson, 4C-DXAWilson and 4C-ADP were compared against 4C-UWW in the cross-validation sample. 4C-DXANickerson, 4C-DXAWilson and 4C-ADP all produced similar validity statistics when compared with 4C-UWW in Hispanic males (all P > 0·05). 4C-DXANickerson also yielded similar BF % and FFM values as 4C-UWW when evaluating the mean differences (constant error (CE)) in Hispanic females (CE = –0·79 % and 0·38 kg; P = 0·060 and 0·174, respectively). However, 4C-DXAWilson produced significantly different BF % and FFM values (CE = 3·22 % and –2·20 kg, respectively; both P < 0·001). Additionally, 4C-DXAWilson yielded significant proportional bias when estimating BF % (P < 0·001), whereas 4C-ADP produced significant proportional bias for BF % and FFM (both P < 0·05) when evaluated in Hispanic females. The present study findings demonstrate that 4C-DXANickerson is a valid measure of BV in Hispanics and is recommended for use in clinics, where DXA is the main body composition assessment technique.


2017 ◽  
Vol 49 (5S) ◽  
pp. 328
Author(s):  
Katie R. Hirsch ◽  
Meredith G. Mock ◽  
Eric T. Trexler ◽  
Malia N.M. Blue ◽  
Abbie E. Smith-Ryan

2016 ◽  
Vol 22 (3) ◽  
pp. 408-416 ◽  
Author(s):  
Sasha M. Rojas ◽  
Joseph G. Grzywacz ◽  
Martha I. Zapata Roblyer ◽  
Rebecca Crain ◽  
Richard C. Cervantes

2001 ◽  
Author(s):  
Nelson A. Portillo-Pena ◽  
Yolanda Suarez-Balcazar ◽  
Lucia Orellana-Demacela

Mathematics ◽  
2021 ◽  
Vol 9 (14) ◽  
pp. 1657
Author(s):  
Jochen Merker ◽  
Benjamin Kunsch ◽  
Gregor Schuldt

A nonlinear compartment model generates a semi-process on a simplex and may have an arbitrarily complex dynamical behaviour in the interior of the simplex. Nonetheless, in applications nonlinear compartment models often have a unique asymptotically stable equilibrium attracting all interior points. Further, the convergence to this equilibrium is often wave-like and related to slow dynamics near a second hyperbolic equilibrium on the boundary. We discuss a generic two-parameter bifurcation of this equilibrium at a corner of the simplex, which leads to such dynamics, and explain the wave-like convergence as an artifact of a non-smooth nearby system in C0-topology, where the second equilibrium on the boundary attracts an open interior set of the simplex. As such nearby idealized systems have two disjoint basins of attraction, they are able to show rate-induced tipping in the non-autonomous case of time-dependent parameters, and induce phenomena in the original systems like, e.g., avoiding a wave by quickly varying parameters. Thus, this article reports a quite unexpected path, how rate-induced tipping can occur in nonlinear compartment models.


Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1209
Author(s):  
Gabriel Keller ◽  
Simon Götz ◽  
Mareen Sarah Kraus ◽  
Leonard Grünwald ◽  
Fabian Springer ◽  
...  

This study analyzed the radiation exposure of a new ultra-low dose (ULD) protocol compared to a high-quality (HQ) protocol for CT-torsion measurement of the lower limb. The analyzed patients (n = 60) were examined in the period March to October 2019. In total, 30 consecutive patients were examined with the HQ and 30 consecutive patients with the new ULD protocol comprising automatic tube voltage selection, automatic exposure control, and iterative image reconstruction algorithms. Radiation dose parameters as well as the contrast-to-noise ratio (CNR) and diagnostic confidence (DC; rated by two radiologists) were analyzed and potential predictor variables, such as body mass index and body volume, were assessed. The new ULD protocol resulted in significantly lower radiation dose parameters, with a reduction of the median total dose equivalent to 0.17 mSv in the ULD protocol compared to 4.37 mSv in the HQ protocol (p < 0.001). Both groups showed no significant differences in regard to other parameters (p = 0.344–0.923). CNR was 12.2% lower using the new ULD protocol (p = 0.033). DC was rated best by both readers in every HQ CT and in every ULD CT. The new ULD protocol for CT-torsion measurement of the lower limb resulted in a 96% decrease of radiation exposure down to the level of a single pelvic radiograph while maintaining good image quality.


Sign in / Sign up

Export Citation Format

Share Document