scholarly journals Does Optic Nerve Sheath Diameter Ultrasonography Permit Accurate Detection of Real-Time Changes in ICP?

2016 ◽  
Vol 48 (7) ◽  
pp. 317-320 ◽  
Author(s):  
Daniel Lesky ◽  
Christopher Schott
2022 ◽  
Vol 14 (1) ◽  
Author(s):  
Jason B. Jennings ◽  
Cynthia Oliva ◽  
Michael Joyce ◽  
Michael J. Vitto ◽  
Jordan Tozer ◽  
...  

Abstract Objectives Ultrasound measurement of the optic nerve sheath diameter (ONSD) is a rapid, non-invasive means to indirectly assess intracranial pressure. Previous research has demonstrated the ability of emergency physicians to measure ONSD accurately with bedside ultrasound when compared to CT scan or MRI, however the reliability of this measurement between two or more operators has been called into question (Hassen et al. in J Emerg Med 48:450–457, 2015; Shirodkar et al. in Ind J Crit Care Med 19:466–470, 2015). Given the need for accurate and precise measurement to use this as a screening exam, we sought to determine the inter-rater reliability between ONSD measurements obtained in real time by fellowship-trained emergency ultrasound physicians. Methods Three ultrasound fellowship-trained emergency physicians measured bilateral ONSD of 10 healthy volunteers using a high-frequency linear transducer. The physicians were blinded to the other scanners’ measurements, and no instructions were given other than to obtain the ONSD. Each sonographer measured the ONSD in real time and it was recorded by a research coordinator. All measurements were recorded in millimeters. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability. Results A total of 60 measurements of ONSD were obtained. The average measurement was 4.3 mm (3.83–4.77). Very little variation was found between the three physicians, with a calculated ICC of 0.82 (95% confidence interval 0.63–0.92). Conclusions ONSD measurement obtained by ultrasound fellowship-trained emergency medicine physicians is a reliable measurement with a high degree of correlation between scanners.


2018 ◽  
Vol 103 (4) ◽  
pp. 437-441 ◽  
Author(s):  
Li-min Chen ◽  
Li-juan Wang ◽  
Yang Hu ◽  
Xiao-han Jiang ◽  
Yu-zhi Wang ◽  
...  

The current study aimed to identify whether ultrasonographic measurements of optic nerve sheath diameter (ONSD) could dynamically and sensitively evaluate real-time intracranial pressure (ICP). ONSD measurements were performed approximately 5  min prior to and after a lumbar puncture (LP). A total of 84 patients (mean±SD age, 43.5±14.7 years; 41 (49%) men; 18 patients with elevated ICP) were included in the study. The Spearman correlation coefficients between the two observers were 0.779 and 0.703 in the transverse section and 0.751 and 0.788 in the vertical section for the left and right eyes, respectively. The median (IQR) change in ONSD (ΔONSD) and change in ICP (ΔICP) were 0.11 (0.05–0.21) mm and 30 (20–40) mmH2O, respectively, for all participants. With a reduction in cerebrospinal fluid pressure, 80 subjects (95%) showed an immediate drop in ONSD; the median (IQR) decreased from 4.13 (4.02–4.38) mm to 4.02 (3.90–4.23) mm (p<0.001). Significant correlations were found between ONSD and ICP before LPs (r=0.482, p<0.01) and between ΔONSD and ΔICP (r=0.451, p<0.01). Ultrasonic measurement of ONSD can reflect the relative real-time changes in ICP.


2018 ◽  
Vol 36 (4) ◽  
pp. 736.e1-736.e3 ◽  
Author(s):  
Getaw Worku Hassen ◽  
Mohammed Al-Juboori ◽  
Barbara Koppel ◽  
Gokhan Akfirat ◽  
Hossein Kalantari