diameter measurement
Recently Published Documents


TOTAL DOCUMENTS

465
(FIVE YEARS 99)

H-INDEX

26
(FIVE YEARS 4)

2021 ◽  
Vol 7 (6) ◽  
pp. 209-217
Author(s):  
Eduardo Frank ◽  
EN Hick ◽  
MVH Castillo ◽  
Gaut MC ◽  
RH Mamani-Cato

The Minifiber EC (MFEC) is a portable instrument for measuring the diameter of animal fibers. Its accuracy and precision have been estimated but by comparing its measurements with those of laboratory devices that had been calibrated on other devices in turn, not on a direct or primary measure of diameter. This work attempts to test direct measurements by gravimetry, Vernier mini caliper, microscope and the classic microprojector, using a non-deformable, high resistance synthetic fiber (Kevlar) for direct measurement. The MFEC instrument is calibrated with each mean fiber diameter obtained in direct measurements and its results are compared. The conclusions drawn are that it is possible to calibrate the MFEC instrument with direct measurements on Kevlar and measurement accuracy or tolerance of 0.28 microns is obtained. This indicates a very low biased mean fiber diameter measurement by MFEC.


2021 ◽  
Vol 8 ◽  
Author(s):  
Timo Siepmann ◽  
Kristian Barlinn ◽  
Thomas Floegel ◽  
Jessica Barlinn ◽  
Lars-Peder Pallesen ◽  
...  

Objective: To determine the diagnostic agreement of CT angiography (CTA) manual multiplanar reformatting (MPR) stenosis diameter measurement and semiautomated perpendicular stenosis area minimal caliber computation of extracranial internal carotid artery (ICA) stenosis.Methods: We analyzed acute cerebral ischemia CTA at our tertiary stroke center in a 12-month period. Prospective NASCET-type stenosis grading for each ICA was independently performed using (1) MPR to manually determine diameters and (2) perpendicular stenosis area with minimal caliber semiautomated computation to grade luminal constriction. Corresponding to clinically relevant NASCET strata, results were grouped into severity ranges: normal, 1–49%, 50–69%, and 70–99%, and occlusion.Results: We included 647 ICA pairs from 330 patients (median age of 74 [66–80, IQR]; 38–92 years; 58% men; median NIHSS 4 [1–9, IQR]). MPR diameter and semiautomated caliber measurements resulted in stenosis grades of 0–49% in 143 vs. 93, 50–69% in 29 vs. 27, 70–99% in 6 vs. 14, and occlusion in 34 vs. 34 ICAs (p = 0.003), respectively. We found excellent reliability between repeated manual CTA assessments of one expert reader (ICC = 0.997; 95% CI, 0.993–0.999) and assessments of two expert readers (ICC = 0.972; 95% CI, 0.936–0.988). For the semiautomated vessel analysis software, both intrarater reliability and interrater reliability were similarly strong (ICC = 0.981; 95% CI, 0.952–0.992 and ICC = 0.745; 95% CI, 0.486–0.883, respectively). However, Bland–Altman analysis revealed a mean difference of 1.6% between the methods within disease range with wide 95% limits of agreement (−16.7–19.8%). This interval even increased with exclusively considered vessel pairs of stenosis ≥1% (mean 5.3%; −24.1–34.7%) or symptomatic stenosis ≥50% (mean 0.1%; −25.7–26.0%).Conclusion: Our findings suggest that MPR-based diameter measurement and the semiautomated perpendicular area minimal caliber computation methods cannot be used interchangeably for the quantification of ICA steno-occlusive disease.


2021 ◽  
Vol 8 (6) ◽  
pp. 8-21
Author(s):  
Sujith Pereira ◽  
Jonathan Reeves ◽  
Malcolm Birch ◽  
Ahmed Ali ◽  
Ajay Sinha ◽  
...  

Diameter form an integral part of blood flow measurement. This study aimed to explore different three-dimensional (3D) printed materials to develop flow phantom models of the carotid artery in preterm newborn infants and to investigate ideal diameter measurement points using ultrasound that reflected accurate lumen diameter measurement. Cerebral blood flow measurements data using Doppler ultrasound of the right common carotid artery from 21 randomly selected preterm infants were used to produce a 3D printed Doppler flow phantom model with three different vessel diameters. Diameters were measured by multiple observers blinded to phantom vessel characteristics and each other’s measurements. 9 measurement points were studied. Agreement between observers, inter and intra observer reliability and coefficient of variation (CoV) was examined. Of the 63 diameter measurements, 45 (71%) were performed on flow phantoms with vessel diameter of 0.196 cm. Bland-Altman plots revealed that measurement performed using leading edge to centre (mean bias 1.8% {95%LOA -4.1% to 7.7%}) and centre to trailing edge (mean bias 1.1% {95%LOA -5.4% to 7.8%}) resulted in the most accurate lumen diameter measurements. Inter and intra-observer reliability was excellent. The mean CoV for inter observer measurements was 1.7% and intra observer measurements was 1.6% and 1.8% for each observer. We successfully produced a 3D printed flow phantom model of the carotid artery in preterm infants and identified two measurement methods that result in reliable and accurate lumen diameter measurement. Researchers and clinicians can use this information for further studies involving ultrasound diameter measurements in small calibre vessels.


Author(s):  
Eddy Nurraharjo ◽  
Zuly Budiarso ◽  
Dewi Handayani U.N. ◽  
Jati Sasongko W.

Sign in / Sign up

Export Citation Format

Share Document