scholarly journals Internal Fixation of Hamate Hook Fracture by Dorsal Percutaneous Headless Compression Screw and Cortical Screw: A Technical Note

2017 ◽  
Vol 22 (4) ◽  
pp. 273
Author(s):  
Sang-Kyu Kang ◽  
Jin-Rock Oh
2012 ◽  
Vol 37 (7) ◽  
pp. 690-693 ◽  
Author(s):  
K. Singisetti ◽  
E. Aldlyami ◽  
A. Middleton

There has been a considerable evolution of screws used for internal fixation of scaphoid fractures. We discuss here, early results of a recently introduced implant Synthes 3.0 mm headless compression screw used for scaphoid fracture fixation. Twenty eight patients with scaphoid fractures (five acute and 23 nonunions) were treated with internal fixation by this non-variable pitch screw over a period of 18 months. All nonunions had pedicle vascularized bone grafting. All five patients with acute scaphoid fracture fixation had radiological healing at a mean of 8 weeks. Fifteen of 23 scaphoid fracture nonunions showed definite signs and a further seven showed probable signs of radiological healing at a mean of 8 months. One nonunion has failed to unite after surgery.


2021 ◽  
Vol 2021 ◽  
pp. 1-4
Author(s):  
Amanda F. Spielman ◽  
Sriram Sankaranarayanan

We report a case of a 28-year-old male who sustained a comminuted trapezium fracture with carpometacarpal subluxation of the right hand. Treatment with internal fixation with a headless compression screw resulted in excellent outcomes.


2017 ◽  
Vol 22 (01) ◽  
pp. 35-38 ◽  
Author(s):  
Eichi Itadera ◽  
Takahiro Yamazaki

We developed a new internal fixation method for extra-articular fractures at the base of the proximal phalanx using a headless compression screw to achieve rigid fracture fixation through a relatively easy technique. With the metacarpophalangeal joint of the involved finger flexed, a smooth guide-pin is inserted into the intramedullary canal of the proximal phalanx through the metacarpal head and metacarpophalangeal joint. Insertion tunnels are made over the guide-pin using a cannulated drill. Then, a headless cannulated screw is placed into the proximal phalanx. All of five fractures treated by this procedure obtained satisfactory results.


Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


2019 ◽  
Vol 12 (S 01) ◽  
pp. S39-S44
Author(s):  
Michael Okoli ◽  
Kevin Lutsky ◽  
Michael Rivlin ◽  
Brian Katt ◽  
Pedro Beredjiklian

Abstract Introduction The purpose of this study is to determine the radiographic dimensions of the finger metacarpals and to compare these measurements with headless compression screws commonly used for fracture fixation. Materials and Methods We analyzed computed tomography (CT) scans of the index, long, ring, and small metacarpal bones and measured the metacarpal length, distance from the isthmus to the metacarpal head, and intramedullary diameter of the isthmus. Metacarpals with previous fractures or hardware were excluded. We compared these dimensions with the size of several commercially available headless screws used for intramedullary fixation. Results A total of 223 metacarpals from 57 patients were analyzed. The index metacarpal was the longest, averaging 67.6 mm in length. The mean distance from the most distal aspect of the metacarpal head to the isthmus was 40.3, 39.5, 34.4, and 31 mm for the index, long, ring, and small metacarpals, respectively. The narrowest diameter of the isthmus was a mean of 2.6, 2.7, 2.3, and 3 mm for the index, long, ring, and small metacarpals, respectively. Of 33 commercially available screws, only 27% percent reached the isthmus of the index metacarpal followed by 42, 48, and 58% in the long, ring, and small metacarpals, respectively. Conclusion The index and long metacarpals are at a particular risk of screw mismatch given their relatively long lengths and narrow isthmus diameters.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yung-Cheng Chiu ◽  
Tsung-Yu Ho ◽  
Yen-Nien Ting ◽  
Ming-Tzu Tsai ◽  
Heng-Li Huang ◽  
...  

Abstract Background Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage. Objective We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture. Materials and methods We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force–displacement curves. Finally, the Kruskal–Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups. Results The maximum fracture forces (median ± interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0 ± 81.0, 156.0 ± 117.9, 60.4 ± 21.0, and 51.8 ± 60.7 N, respectively. In addition, the stiffness values (median ± IQR) of the LP, HC, RP, and K groups were 29.6 ± 3.0, 23.1 ± 5.2, 22.6 ± 2.8, and 14.7 ± 5.6 N/mm, respectively. Conclusion Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.


Author(s):  
Hassan A. Qureshi ◽  
Kashyap Komarraju Tadisina ◽  
Gianfranco Frojo ◽  
Kyle Y. Xu ◽  
Bruce A. Kraemer

Abstract Background Isolated traumatic lunate fractures without other surgical carpal bone or ligamentous injuries are extremely rare, with few published reports available to guide management. Lunate fracture management is controversial, and depends on concurrent injuries of adjacent carpal bones, ligaments, risk of ischemia, and displacement. Case Description A 48-year-old right hand dominant man suffered a crush injury to the left hand caught between a forklift and a metal shelf. Radiographs and computed tomography imaging of the left hand and wrist were significant for a displaced Teisen IV fracture of the lunate. A dorsal ligament sparing approach was utilized to access, reduce, and fixate the fracture using a headless compression screw. After immobilization and rehab, at 9 months after initial injury, the patient was back to work on full duty without restriction and pleased with the results of his treatment. Literature Review A literature review of lunate fracture compression screw fixation was performed and revealed a total of three reports indicating successful treatment of fractures, with patients returning to full activity. Clinical Relevance Lunate fractures are rare, often missed, and treating these injuries can be challenging, particularly in the setting of acute trauma. Based on our limited experience, we believe that open reduction and internal fixation of isolated Teisen IV lunate fractures with a headless compression screw is a viable treatment modality with satisfactory outcomes.


1984 ◽  
Vol 55 (4) ◽  
pp. 423-429 ◽  
Author(s):  
Svein Svenningsen ◽  
Pål Benum ◽  
Olav Nesse ◽  
Odd Ivar Furset

Sign in / Sign up

Export Citation Format

Share Document