scholarly journals THE EFFECT OF TREATED SEWAGE OUTFLOW FROM A MODERNIZED SEWAGE TREATMENT PLANT ON WATER QUALITY OF THE BREŃ RIVER

2015 ◽  
Vol 16 ◽  
pp. 96-102 ◽  
Author(s):  
Tomasz Kowalik ◽  
Andrzej Bogdał ◽  
Łukasz Borek ◽  
Aleksandra Kogut
2008 ◽  
Vol 37 (2) ◽  
Author(s):  
Maciej Walczak

Changes of microbial indices of water quality in the Vistula and Brda rivers as a result of sewage treatment plant operationThis paper reports the results of studies of microbiological changes in the water quality of the Vistula and Brda rivers after the opening of sewage treatment plants in Bydgoszcz. The study involved determining the microbiological parameters of water quality. Based on the results obtained, it was found that the quality of the water in both rivers had improved decidedly after the opening of the plants, although an increased number of individual groups of microorganisms was found at the treated sewage outlet from one of the plants.


2020 ◽  
Vol 8 (2) ◽  
pp. 1915-1921
Author(s):  
Hafsa Farooq Chashoo ◽  
Adnan Abubakr ◽  
MH Balkhi ◽  
Tasaduq H Shah ◽  
Rizwana Malik ◽  
...  

2020 ◽  
Vol 20 (3) ◽  
pp. 145-159
Author(s):  
Donat Hansz ◽  
Katarzyna Kowalczewska-Madura

AbstractThe study on a small lowland river was conducted in order to determine changes in water quality under external loading (inflow of treated wastewater, runoff from agricultural areas) and the location of a dam reservoir in its course. The 21 km long River Pogona (Greater Poland, Poland) is a small tributary of the Obra Canal in Kościan. In 2004, in its valley, the Jeżewo Reservoir, with an area of 78 ha, was utilized to supply the flow in the Obra Canal during the dry season and to irrigate agricultural areas. The river is also a receiver of treated sewage from the sewage treatment plant in Karolewo. The research, carried out in 2017 at six sampling stations in its course, showed that the discharge of treated wastewater resulted in an increase in conductivity, concentration of ammonium nitrogen, nitrites and total nitrogen in the waters of the River Pogona. On the other hand, the location of the Jeżewo Reservoir in its course contributed to an increase in water temperature, pH, dissolved oxygen, chlorophyll-a and nitrite concentration in the outflowing river. The results showed that the inflow of treated wastewater from the sewage treatment plant, surface runoff from the catchment area and the Jeżewo Reservoir formed in its course, influenced seasonal and spatial changes in the water quality of the River Pogona.


2017 ◽  
Vol 34 (1) ◽  
pp. 153-162 ◽  
Author(s):  
Włodzimierz Kanownik ◽  
Agnieszka Policht-Latawiec ◽  
Anna Gajda

Abstract The paper presents an analysis of 20 physicochemical elements in the Bobrza River water sampled above and below the treated sewage discharge point. Sitkówka mechanical and biological sewage treatment plant with a value of 289 000 People Equivalent discharges on average 51 000 m3 of treated sewage daily, which makes up 29% of mean daily flow in the Bobrza River. On the basis of hydrochemical analyses it was stated that the discharge of treated sewage led to worsening of 18 out of 20 studied water quality indices in the Bobrza River. In the river water below the sewage discharge statistically significantly higher values of electrolytic conductivity, dissolved solids, calcium, magnesium, sodium and potassium were registered. A decrease in dissolved oxygen content in the water and increase in its electrolytic conductivity caused a change of water quality class in the Bobrza River from the maximum potential to potential below good. On the other hand, increase in concentrations of dissolved solids and sulphates caused a change of the water class from the maximum potential to good potential. Statistical factor analysis (FA) made possible a reduction of a set of 20 physicochemical elements to four mutually orthogonal factors explaining 95% (above the treatment plant) and 96% (below the treatment plant) of the internal structure of primary data. The first factor is connected with point source pollution (sewage discharge), the second describes oxygen conditions in water, the third results from seasonality and is responsible for the pollutants from natural sources, whereas the fourth factor has not been unanimously defined yet.


2018 ◽  
Vol 43 (2) ◽  
pp. 51
Author(s):  
Karine Andréa Costa ◽  
Elizabeth Weinhardt Oliveira Scheffer ◽  
Patrícia Los Weinert ◽  
Estevan Luis Silveira

The objective of this work was to evaluate the physicochemical parameters that express the water quality of the Rio Verde, in the city of Ponta Grossa, Paraná. Multivariate Analysis was used, and quality indexes were obtained, such as the Trophic State Index and the Water Quality Index for Aquatic Life Protection. River samples were collected at 4 points along the  Rio Verde for 12 months. The study showed that the river presents a high trophic degree, and that it can be considered hypereutrophic, and that phosphorus concentration is determinant for this situation. The results indicated that, at point 4, downstream from the Sewage Treatment Plant, the aquatic environment is very poor for the biota. The disposal of the effluent was indicated as the cause, and it is assumed that the river has no flow capacity  to receive this contribution, without suffering impact. It was also concluded that points 1 and 2 correspond to more preserved sites, but are not totally favorable to aquatic life either because they receive surface drainage from agricultural areas in the basin. Point 3, of urban character, suffers an impact caused by irregular connections of sewers, and contribution of streams that flow into the river.


2010 ◽  
Vol 19 (3) ◽  
pp. 323-329 ◽  
Author(s):  
Mi-Ran Kim ◽  
Kyoung-Hee Kim ◽  
Hae-Sik Park ◽  
Dong-Hyo Kang ◽  
Jea-Keun Lee

2013 ◽  
Vol 671-674 ◽  
pp. 2736-2741
Author(s):  
Yin An Ming ◽  
Tao Tao

To reuse municipal sewage sludge safely, experiment was carried out on grapefruit trees fertilized with composted sludge from Shiweitou Sewage Treatment Plant in Xiamen City of China, and a method was introduced of how to assess the environmental quality of grapefruit trees soil fertilized with sludge by Set Pair Analysis (SPA) model. The results showed that the soil in the surface layer (0-15cm) and the deeper layer (15-30cm) was less clean, and the environment of soil was not polluted. Thus it was feasible to use sludge as fruit fertilizer. The maximum service life of sludge for continuous land application was estimated by taking Cd as the limiting factor, which would provide scientific guide and technical support for safe land application of sludge.


2019 ◽  
Vol 136 ◽  
pp. 06031
Author(s):  
Shen Dongmei ◽  
Yu Cairui ◽  
Gao Yulan ◽  
Song Xinwei ◽  
Chu Jingsong

A sewage treatment plant is located in the middle of Inner Mongolia. There is a large amount of slaughtering wastewater in the influent with high COD, SS, low annual temperature, poor nitrogen removal effect, and the effluent quality is only grade B. In order to solve the above problems, A\A\O-MBBR + high efficiency sedimentation tank continuous sand filter process was adopted to establish a new anaerobic tank and a first stage AO-MBBR bioreactor. The selection tank and partial oxidation ditch were transformed into the second stage A pool (anoxic pool), and the remaining part of the existing oxidation ditch was transformed into the second stage O pond (aerobic pool), which further removed phosphorus and reduced the SS in the sewage, and solved the problem of low temperature biological treatment in winter in the north of China. The quality of the effluent reached level A after the upgrading.


2018 ◽  
Vol 45 ◽  
pp. 00036
Author(s):  
Zbigniew Kowalewski

The process of designing and exploiting municipal sewage treatment plants has become much simpler and more efficient thanks to mathematical modeling. The ASM model family is able to simulate the operation of existing or designed objects in a satisfactory manner. The basic problem in Poland is the insufficient amount of data for simulations coming from plant monitoring. It is provided to create unstable model results with difficulties in calibration and validation. The aim of this article is to confirm how the amount of data and its completeness will affect the quality of the simulation performed in the ASM model. The study object is a sewage treatment plant located in Chicago in the USA. It is a sewage treatment plant operating with activated sludge technology, with regular monitoring of the quality of raw and treated wastewater. For modeling, a variant of the ASM model built into the BioWin 5.2 software was used.


Sign in / Sign up

Export Citation Format

Share Document