scholarly journals Influence of Sitkówka sewage treatment plant on the Bobrza River water quality

2017 ◽  
Vol 34 (1) ◽  
pp. 153-162 ◽  
Author(s):  
Włodzimierz Kanownik ◽  
Agnieszka Policht-Latawiec ◽  
Anna Gajda

Abstract The paper presents an analysis of 20 physicochemical elements in the Bobrza River water sampled above and below the treated sewage discharge point. Sitkówka mechanical and biological sewage treatment plant with a value of 289 000 People Equivalent discharges on average 51 000 m3 of treated sewage daily, which makes up 29% of mean daily flow in the Bobrza River. On the basis of hydrochemical analyses it was stated that the discharge of treated sewage led to worsening of 18 out of 20 studied water quality indices in the Bobrza River. In the river water below the sewage discharge statistically significantly higher values of electrolytic conductivity, dissolved solids, calcium, magnesium, sodium and potassium were registered. A decrease in dissolved oxygen content in the water and increase in its electrolytic conductivity caused a change of water quality class in the Bobrza River from the maximum potential to potential below good. On the other hand, increase in concentrations of dissolved solids and sulphates caused a change of the water class from the maximum potential to good potential. Statistical factor analysis (FA) made possible a reduction of a set of 20 physicochemical elements to four mutually orthogonal factors explaining 95% (above the treatment plant) and 96% (below the treatment plant) of the internal structure of primary data. The first factor is connected with point source pollution (sewage discharge), the second describes oxygen conditions in water, the third results from seasonality and is responsible for the pollutants from natural sources, whereas the fourth factor has not been unanimously defined yet.

2008 ◽  
Vol 37 (2) ◽  
Author(s):  
Maciej Walczak

Changes of microbial indices of water quality in the Vistula and Brda rivers as a result of sewage treatment plant operationThis paper reports the results of studies of microbiological changes in the water quality of the Vistula and Brda rivers after the opening of sewage treatment plants in Bydgoszcz. The study involved determining the microbiological parameters of water quality. Based on the results obtained, it was found that the quality of the water in both rivers had improved decidedly after the opening of the plants, although an increased number of individual groups of microorganisms was found at the treated sewage outlet from one of the plants.


Author(s):  
Włodzimierz Kanownik ◽  
Agnieszka Policht-Latawiec ◽  
Magdalena Wiśnios

Abstract The paper presents changes in the contents of physicochemical indices of the Sudół stream water caused by a discharge of purified municipal sewage from a small mechanical-biological treatment plant with throughput of 300 m3·d−1 and a population equivalent (p.e.) – 1,250 people. The discharge of purified sewage caused a worsening of the stream water quality. Most of the studied indices values increased in water below the treatment plant. Almost a 100-fold increase in ammonium nitrogen, 17-fold increase in phosphate concentrations and 12-fold raise in BOD5 concentrations were registered. Due to high values of these indices, the water physicochemical state was below good. Statistical analysis revealed a considerable effect of the purified sewage discharge on the stream water physicochemical state. A statistically significant increase in 10 indices values (BOD5, COD-Mn, EC, TDS, Cl−, Na+, K+, PO43−, N-NH4+ and N-NO2) as well as significant decline in the degree of water saturation with oxygen were noted below the sewage treatment plant. On the other hand, no statistically significant differences between the water indices values were registered between the measurement points localised 150 and 1,000 m below the purified sewage discharge. It evidences a slow process of the stream water self-purification caused by an excessive loading with pollutants originating from the purified sewage discharge.


Ecotoxicology ◽  
2016 ◽  
Vol 25 (10) ◽  
pp. 1849-1857 ◽  
Author(s):  
Dalel Belhaj ◽  
Khaled Athmouni ◽  
Bouthaina Jerbi ◽  
Monem Kallel ◽  
Habib Ayadi ◽  
...  

1993 ◽  
Vol 39 (10) ◽  
pp. 990-993 ◽  
Author(s):  
M. Arturo ◽  
Z. Tamanai-Shacoori ◽  
C. Mamez ◽  
M. Pommepuy ◽  
M. Cormier

The plasmid contents of 306 strains of Escherichia coli isolated from raw and treated sewage from a treatment plant as well as from the water 1 km downstream were determined. The number and molecular weight of plasmids isolated from a representative sample of these strains were also measured. It was observed that biological treatment did not significantly alter these parameters. In contrast, statistically significant differences in plasmid number and size were observed when strains from sewage (raw and treated) were compared with strains isolated from brackish water. In raw and treated sewage, more than 96% of the strains contained plasmids, compared with 85% in brackish water. Nine to 13% of the strains from sewage contained plasmids with more than 56 kilobases, while only 5% of the strains from brackish water reached this size.Key words: Escherichia coli, plasmids, two-dimensional electrophoresis, sewage treatment, brackish water.


2013 ◽  
Vol 295-298 ◽  
pp. 1380-1383
Author(s):  
Lei Zhu ◽  
Song Liu ◽  
Xun Wang ◽  
Hong Jiao Song

A pharmaceutical factory in Wuhan produces many pharmaceutical wastewaters every day. The wastewater raw water quality indexes are: the concentration of COD,BOD5, NH3-N,TP is 300,000mg/L, 200,000mg/L, 450mg/L,900 mg/L ; By the SBBR treatment, the effluent water quality indexes are:750mg/L,350mg/L,1.20mg/L,5mg/L,and the effluent water can accord with Wastewater quality standards for discharge to municipal sewers (CJ 343-2010) and be discharged after treatment in the sewage treatment plant by municipal sewers.


2013 ◽  
Vol 385-386 ◽  
pp. 857-861
Author(s):  
Xiao Ping Huang ◽  
Qi Xing Qing

On the basis of the computerized technological process control of sewage treatment in a urban sewage treatment plant in the Zone of Nanning, the author had brought forward a plan of PROFIBUS that based on automatic control system for sewage treatment, and designed the automatic control system diagram and the PROFIBUS network diagram for sewage treatment plant. At the same time, the author also made a study of techniques to control the sewage aeration, which was the most difficult problem in sewage treatment process. The fuzzy controller could indicate the changes of the water quality in treated sewage, effectively controlled the volume of aeration and then cut down the operation costs,it had produced good economic and social benefits.


Sign in / Sign up

Export Citation Format

Share Document