scholarly journals Alternative Mechanical Evaluation Method for Ceramic Hip Joint Implants Utilizing Finite Element Analysis under in vivo-like Conditions

2012 ◽  
Vol 7 (4) ◽  
pp. 336-348 ◽  
Author(s):  
Sungmin HAN ◽  
Jun-Uk CHU ◽  
Kang-Il SONG ◽  
Sunghee PARK ◽  
Jea Bong CHOI ◽  
...  
2019 ◽  
Vol 11 (11) ◽  
pp. 168781401988764
Author(s):  
Ghulam Moeen Uddin ◽  
Muhammad Waqar Nasir ◽  
Syed Muhammad Arafat ◽  
Syed Wasim Hassan Zubair ◽  
Abdul Rehman ◽  
...  

This research article presents a design parameter assessment technique for three-dimensional printed hip joint implants. A coupled experimental-simulation-based design technique, addressing minimum coating thickness, hardness, and adhesion requirements, is proposed for safe designs of individual three-dimensional printed hip joint implants. The purpose of this study is to analyze the mechanical properties of individual three-dimensional scanned hip joint human bone geometry through numerical simulation and relate these properties to hardness and adhesion values of bio-compatible coatings. The hardness and adhesion experimental results are discussed, which are then related to numerically obtained normal and shear stresses. Finite element analysis on original bone three-dimensional scanned model along with experimental results for investigating the minimum design requirements has not been reported before. Four ceramic coating materials, that is, alumina, CoCrMo, TiN, and zirconia, are discussed for each routine human physical activity. A comprehensive mesh independence study is conducted to ensure that the mesh has no effect on the variation of results. After finite element analysis, it was concluded that the pelvis bone can be taken as a vital bone for recommending design conditions. The finite element results are then coupled with experimental results as the maximum principal stress obtained from the finite element analysis is used to obtain minimum hardness requirements. Similarly, maximum shear stress obtained from the finite element analysis is used to obtain minimum adhesion requirements for three-dimensional printed implants. The coating thickness necessary to obtain minimum hardness and adhesion requirements is then predicted for TiN coating case.


Author(s):  
M. C. Gaspar ◽  
A. Mateus ◽  
C. Pereira ◽  
F. V. Antunes

In this work a Bombelli cementless isoelastic RM total hip prosthesis was considered. It was implanted over a course of 14 years on the patient and studied subsequently to its chirurgical replacement. Computed Tomography, radiographies and 3-D laser scanning were used to assess the prosthesis geometry, while the original femur anatomy was modeled based on 2-D radiographies taken at different stages of the in-vivo implant of the prosthesis. A finite element model was developed, based on the generated 3-D geometrical model, considering a linear elastic behavior and typical loading conditions. This analysis allowed determining stress and strain fields throughout bone-prosthesis contact surface and critical areas in terms of micromovements. The developed procedure, consisting of 3-D scanning, generation of geometrical 3-D models and finite element analysis, results in a powerful tool to follow-up and predict failure mechanisms in hip joint prosthesis.


Sign in / Sign up

Export Citation Format

Share Document