scholarly journals Cycle Analysis of Micro Gas Turbine-Molten Carbonate Fuel Cell Hybrid System

2005 ◽  
Vol 48 (1) ◽  
pp. 65-74 ◽  
Author(s):  
Shinji KIMIJIMA ◽  
Nobuhide KASAGI
Author(s):  
Ji Ho Ahn ◽  
Tong Seop Kim

Owing to the increasing consumption of fossil fuels and emission of greenhouse gases, interests in highly efficient and low carbon emitting power systems are growing fast. Several research groups have been suggesting advanced systems based on fuel cells and have also been applying carbon capture and storage technology to satisfy the demand for clean energy. In this study, the performance of a hybrid system, which is a combination of a molten carbonate fuel cell (MCFC) with oxy-combustion carbon capture and an indirectly fired micro gas turbine (MGT) was predicted. A 2.5MW MCFC system that is used in commercial applications was used as the reference system so that the results of the study could be applicable to practical situations. The ambient pressure type hybrid system was modeled by referring to the design parameters of an MGT that is currently being developed. A semi-closed type design characterized by flow recirculation was adopted for this hybrid system. A part of the recirculating gas is converted into liquefied carbon dioxide and captured for storage at the carbon separation unit. Almost 100% carbon dioxide capture is possible with this system. In these systems, the output power of the fuel cell is larger than in the normal hybrid system without carbon capture because the partial pressure of carbon dioxide increases. The increased cell power partially compensates for the power loss due to the carbon capture and MGT power reduction. The dependence of net system efficiency of the oxy-hybrid on compressor pressure ratio is marginal, especially beyond an optimal value.


Author(s):  
Ji Ho Ahn ◽  
Tong Seop Kim

Owing to the increasing consumption of fossil fuels and emission of greenhouse gases, interests in highly efficient and low carbon emitting power systems are growing fast. Several research groups have been suggesting advanced systems based on fuel cells and have also been applying carbon capture and storage technology to satisfy the demand for clean energy. In this study, the performance of a hybrid system, which is a combination of a molten carbonate fuel cell (MCFC) with oxy-combustion carbon capture and an indirectly fired micro gas turbine (MGT), was predicted. A 2.5 MW MCFC system that is used in commercial applications was used as the reference system so that the results of the study could be applied to practical situations. The ambient pressure type hybrid system was modeled by referring to the design parameters of an MGT that is currently being developed. A semi-closed type design characterized by flow recirculation was adopted for this hybrid system. A part of the recirculating gas is converted into liquefied carbon dioxide and captured for storage at the carbon separation unit (CSU). Almost 100% carbon dioxide capture is possible with this system. In these systems, the output power of the fuel cell is larger than in the normal hybrid system without carbon capture because the partial pressure of carbon dioxide increases. The increased cell power partially compensates for the power loss due to the carbon capture and MGT power reduction. The dependence of net system efficiency of the oxy-hybrid on compressor pressure ratio is marginal, especially beyond an optimal value.


Author(s):  
Ji Ho Ahn ◽  
Ji Hun Jeong ◽  
Tong Seop Kim

The demand for clean energy continues to increase as the human society becomes more aware of environmental challenges such as global warming. Various power systems based on high-temperature fuel cells have been proposed, especially hybrid systems combining a fuel cell with a gas turbine, and research on carbon capture and storage technology to prevent the emission of greenhouse gases is already underway. This study suggests a new method to innovatively enhance the efficiency of a molten carbonate fuel cell/micro gas turbine hybrid system including carbon capture. The key technology adopted to improve the net cycle efficiency is off-gas recirculation. The hybrid system incorporating oxy-combustion capture was devised, and its performance was compared with that of a post-combustion system based on a hybrid system. A molten carbonate fuel cell system based on a commercial unit was modeled. Externally supplied water for reforming was not needed as a result of the presence of the water vapor in the recirculated anode off-gas. The analyses confirmed that the thermal efficiencies of all the systems (MCFC stand-alone, hybrid, hybrid with oxy-combustion capture, hybrid with post-combustion capture) were significantly improved by introducing the off-gas recirculation. In particular, the largest efficiency improvement was observed for the oxy-combustion hybrid system. Its efficiency is over 57% and is even higher than that of the post-combustion hybrid system.


2010 ◽  
Vol 35 (7) ◽  
pp. 2997-3000 ◽  
Author(s):  
Jarosław Milewski ◽  
Tomasz Świercz ◽  
Krzysztof Badyda ◽  
Andrzej Miller ◽  
Antoni Dmowski ◽  
...  

2012 ◽  
Vol 33 (3) ◽  
pp. 445-461 ◽  
Author(s):  
Jarosław Milewski ◽  
Andrzej Miller

Abstract Based on mathematical modelling and numerical simulations, a control strategy for a Molten Carbonate Fuel Cell Hybrid System (MCFC-HS) is presented. Adequate maps of performances with three independent parameters are shown. The independent parameters are as follows: stack current, fuel mass flow and compressor outlet pressure. Those parameters can be controlled by external load, fuel valve and turbine-compressor shaft speed, respectively. The control system is purposed to meet many constraints: e.g. stack temperature, steam-to-carbon ratio, compressor surge limitation, etc. The aim is to achieve maximum efficiency of power generated within these constraints. Governing equations of MCFC-HS modelling are given. An operational line of the MCFC-GT system is presented which fulfils several constraints (temperature difference, cell temperature, etc.) The system is able to achieve efficiency of more than 62% even in part-load operation.


Author(s):  
Ai-guo Liu ◽  
Yi-wu Weng

This paper presented the work on the design and part-load operation of a power generation system composed of a pressurized molten carbonate fuel cell and a micro-gas turbine (MCFC/MGT). The gas turbine was based on the commercially available one and the MCFC was assumed to be newly designed for the hybrid system. The effect of different control strategies on the performance of system during part-load operation has been analyzed. Performance of system and gas turbine was compared at the same part-load considering the different control strategies. The results show that the system efficiency is lower compared with the same systems analyzed by the other authors. The system has good performance when both the turbine inlet temperature and cell temperature are maintained close to the design-point condition, but it is difficult for gas turbine to obtain the original power.


Author(s):  
Huisheng Zhang ◽  
Lijin Wang ◽  
Shilie Weng ◽  
Ming Su

The intention of this work is to investigate the control characteristics of molten carbonate fuel cell hybrid systems through dynamic simulation. Because of the complexity and interaction between different components in the hybrid systems, several parameters, such as the turbine rotational speed, the temperatures within the fuel cell, the differential pressure between the anodic and the cathodic side, the steam-to-carbon ratio, need to be monitored and kept within safe limits. On the other hand, the system response to load variations is required to be as quick as possible in order to meet the energy demand. Several control loops were introduced into the hybrid system, the paper focuses on the control performance to regulate the net electrical power from the hybrid system, avoiding malfunctions or damage. The results for several operating conditions are presented and discussed.


Sign in / Sign up

Export Citation Format

Share Document