4124 Development of Cross-Flow Fans by means of Aerodynamic Noise Prediction Model

2006 ◽  
Vol 2006.2 (0) ◽  
pp. 439-440
Author(s):  
Yasushi SHIGENAGA ◽  
Shigehisa FUNABASHI ◽  
Masatoshi WATANABE ◽  
Yoshihiro TAKADA
2008 ◽  
Vol 130 (9) ◽  
Author(s):  
Rafael Ballesteros-Tajadura ◽  
Sandra Velarde-Suárez ◽  
Juan Pablo Hurtado-Cruz

Centrifugal fans are widely used in several applications, and in some cases, the noise generated by these machines has become a serious problem. The centrifugal fan noise is frequently dominated by tones at the blade passing frequency as a consequence of the strong interaction between the flow discharged from the impeller and the volute tongue. In this study, a previously published aeroacoustic prediction methodology (Cho, Y., and Moon, Y.J., 2003, “Discrete Noise Prediction of Variable Pitch Cross-Flow Fans by Unsteady Navier-Stokes Computations,” ASME J. Fluids Eng., 125, pp. 543–550) has been extended to three-dimensional turbulent flow in order to predict the noise generated by a centrifugal fan. A three-dimensional numerical simulation of the complete unsteady flow on the whole impeller-volute configuration has been carried out using the computational fluid dynamics code FLUENT®. The unsteady forces applied by the fan blades to the fluid are obtained from the data provided by the simulation. The Ffowcs Williams and Hawkings model extension of Lighthill’s analogy has been used to predict the aerodynamic noise generated by the centrifugal fan from these unsteady forces. Also, the noise generated by the fan has been measured experimentally, and the experimental results have been compared to the numerical results in order to validate the aerodynamic noise prediction methodology. Reasonable agreement has been found between the numerical and the experimental results.


2012 ◽  
Vol 3 (4) ◽  
pp. 110-112
Author(s):  
Rahul Singh ◽  
◽  
Parveen Bawa ◽  
Ranjan Kumar Thakur

2017 ◽  
Author(s):  
Rahul Gurav ◽  
Kishor D Udawant ◽  
Ramkumar Rajamanickam ◽  
N V Karanth ◽  
S R Marathe

2019 ◽  
Vol 58 (8) ◽  
pp. 3258-3268 ◽  
Author(s):  
Vineet Vishwakarma ◽  
Markus Schubert ◽  
Uwe Hampel
Keyword(s):  

Processes ◽  
2019 ◽  
Vol 7 (12) ◽  
pp. 959
Author(s):  
Weijie Zhang ◽  
Jianping Yuan ◽  
Qiaorui Si ◽  
Yanxia Fu

Cross-flow fans are widely used in numerous applications such as low-pressure ventilation, household appliances, laser instruments, and air-conditioning equipment. Cross-flow fans have superior characteristics, including simple structure, small size, stable airflow, high dynamic pressure coefficient, and low noise. In the present study, numerical simulation and experimental research were carried out to study the unique secondary flow and eccentric vortex flow characteristics of the internal flow field in multi-operating conditions. To this end the vorticity and the circumferential pressure distribution in the air duct are obtained based on the performed experiments and the correlation between spectral characteristics of multiple operating conditions and the inflow state is established. The obtained results show that when the area of the airflow passage decreases while the area of the eccentric vortex area gradually increases, then the airflow of the cross-flow fan decreases, the outlet expands, and the flow pattern uniformity reduces. It was found that wakes form in the vicinity of the blade and the tail of the volute tongue, which generate pressure pulsation, and aerodynamic noise. The pressure distribution along the inner circumference shows that the total minimum pressure appears in the eccentric vortex near the volute tongue and the volute returns near the zone. Moreover, it was found that the total pressure near the eccentric vortex is significantly smaller than that of the main flow zone. As the flow rate decreases, the pressure pulsation amplitude of the eccentric vortex region significantly increases, while the static and total pressure pulsation amplitudes are gradually increased. Close to the eccentric vortex on the inner side of the blade in the volute tongue area, total pressure is low, total pressure on the outside of the blade is not affected, and pressure difference between the inner and outer sides is large. When the flow rate of the cross-flow fan is 0.4 Qd, there is no obvious peak at the harmonic frequency of the blade passage frequency. This shows that the aerodynamic noise is caused by the main unstable flow.


Sign in / Sign up

Export Citation Format

Share Document