Study of the Self-calibration Technique with Fizeau Interferometer and a Planar Scale Grating

2020 ◽  
Vol 2020.55 (0) ◽  
pp. 131_paper
Author(s):  
Xin XIONG ◽  
Hiraku MATSUKUMA ◽  
Yuki SHIMIZU ◽  
Wei GAO
Author(s):  
Ryan E. Reinke ◽  
Harry Dankowicz

This paper discusses the development of a method for on-the-fly, self-calibration of a mass-flow sensing system on a harvest combine in order to enable accurate mass-flow sensing and, consequently, yield mapping, under varying input conditions, for example due to changes in the moisture content of harvested grains or the aging of elevator paddles. The proposed method relies on a known or estimated physics-based relationship between the grain dynamics through the grain elevator and a measured force imparted on an impact plate through collisions with the grains. The paper provides a summary description of the modeled relationship between the rate of mass flow and impact-plate sensor readout and conceptualizes the self-calibration scheme through the introduction of an additional, controllable, degree of freedom of the plate. The validity of the self-calibration technique is illustrated through off-line application to bench-top and full-scale experimental test data.


Author(s):  
M. A. Abbas ◽  
H. Setan ◽  
Z. Majid ◽  
A. K. Chong ◽  
L. Chong Luh ◽  
...  

Similar to other electronic instruments, terrestrial laser scanner (TLS) can also inherent with various systematic errors coming from different sources. Self-calibration technique is a method available to investigate these errors for TLS which were adopted from photogrammetry technique. According to the photogrammetry principle, the selection of datum constraints can cause different types of parameter correlations. However, the network configuration applied by TLS and photogrammetry calibrations are quite different, thus, this study has investigated the significant of photogrammetry datum constraints principle in TLS self-calibration. To ensure that the assessment is thorough, the datum constraints analyses were carried out using three variant network configurations: 1) minimum number of scan stations; 2) minimum number of surfaces for targets distribution; and 3) minimum number of point targets. Based on graphical and statistical, the analyses of datum constraints selection indicated that the parameter correlations obtained are significantly similar. In addition, the analysis has demonstrated that network configuration is a very crucial factor to reduce the correlation between the calculated parameters.


2015 ◽  
Vol 42 (12) ◽  
pp. 1208001
Author(s):  
洪洋 Hong Yang ◽  
孙秀霞 Sun Xiuxia ◽  
蔡鸣 Cai Ming ◽  
刘树光 Liu Shuguang ◽  
付强 Fu Qiang

Sign in / Sign up

Export Citation Format

Share Document