scholarly journals Temperature Measurements near Heating Surface at High Heat Flux in Subcooled Pool Boiling(Thermal Engineering)

2009 ◽  
Vol 75 (753) ◽  
pp. 1127-1134
Author(s):  
Ayako ONO ◽  
Hiroto SAKASHITA
Author(s):  
Aranya Chauhan ◽  
Satish G. Kandlikar

Abstract The trend of miniaturization in electronics presents a great challenge in the thermal management of devices. The continuous increase in the number of transistors in the processor leads to high heat flux generation, limiting the performance of the device. Boiling heat transfer offers a great heat removal competency while maintaining the low chip temperatures. The critical heat flux (CHF) dictates the maximum heat removal ability, and heat transfer coefficient (HTC) defines the efficiency of the boiling process. This pool boiling study is focused on using a manifold containing a symmetric dual taper over the heating surface. The heat transfer performance of this configuration is evaluated for different taper angles in the manifold. The macro-convection assisted by vapor columns during boiling enhance the CHF and HTC limit significantly. A CHF of 287 W/cm2 with an HTC of 116 kW/cm2°C was achieved with a plain copper surface, representing greater than a 2-fold increases in each over a plain surface.


1986 ◽  
Vol 29 (12) ◽  
pp. 1953-1961 ◽  
Author(s):  
A.M. Bhat ◽  
J.S. Saini ◽  
R. Prakash

Author(s):  
Yasuhisa Shinmoto ◽  
Shinichi Miura ◽  
Koichi Suzuki ◽  
Yoshiyuki Abe ◽  
Haruhiko Ohta

Recent development in electronic devices with increased heat dissipation requires severe cooling conditions and an efficient method for heat removal is needed for the cooling under high heat flux conditions. Most researches are concentrated on small semiconductors with high heat flux density, while almost no existing researches concerning the cooling of a large semiconductor, i.e. power electronics, with high heat generation density from a large cooling area. A narrow channel between parallel plates is one of ideal structures for the application of boiling phenomena which uses the cooling for such large semiconductors. To develop high-performance cooling systems for power electronics, experiments on increase in critical heat flux (CHF) for flow boiling in narrow channels by improved liquid supply was conducted. To realize the cooling of large areas at extremely high heat flux under the conditions for a minimum gap size and a minimum flow rate of liquid supplied, the structure with auxiliary liquid supply was devised to prevent the extension of dry-patches underneath flattened bubbles generated in a narrow channel. The heating surface was experimented in two channels with different dimensions. The heating surfaces have the width of 30mm and the lengths of 50mm and 150mm in the flow direction. A large width of actual power electronics is realizable by the parallel installation of the same channel structure in the transverse direction. The cooling liquid is additionally supplied via sintered metal plates from the auxiliary unheated channels located at sides or behind the main heated channel. To supply the liquid to the entire heating surface, fine grooves are machined on the heating surface for enhance the spontaneous liquid supply by the aid of capillary force. The gap size of narrow channels are varied as 0.7mm, 2mm and 5mm. Distribution of liquid flow rate to the main heated channel and the auxiliary unheated channels were varied to investigate its effect on the critical heat flux. Test liquids employed are R113, FC72 and water. The systematic experiments by using water as a test liquid were conducted. Critical heat flux values larger than 2×106W/m2 were obtained at both gap sizes of 2mm and 5mm for a heated length of 150mm. A very high heat transfer coefficient as much as 1×105W/m2K was obtained at very high heat flux near CHF for the gap size of 2mm. This paper is a summary of experimental results obtained in the past by the present authors.


2014 ◽  
Vol 136 (4) ◽  
Author(s):  
J. Jung ◽  
S. J. Kim ◽  
J. Kim

Experimental work was undertaken to investigate the process by which pool-boiling critical heat flux (CHF) occurs using an IR camera to measure the local temperature and heat transfer coefficients on a heated silicon surface. The wetted area fraction (WF), the contact line length density (CLD), the frequency between dryout events, the lifetime of the dry patches, the speed of the advancing and receding contact lines, the dry patch size distribution on the surface, and the heat transfer from the liquid-covered areas were measured throughout the boiling curve. Quantitative analysis of this data at high heat flux and transition through CHF revealed that the boiling curve can simply be obtained by weighting the heat flux from the liquid-covered areas by WF. CHF mechanisms proposed in the literature were evaluated against the observations.


2019 ◽  
Vol 2 (9) ◽  
pp. 5538-5545 ◽  
Author(s):  
Hangbo Zhao ◽  
Susmita Dash ◽  
Navdeep Singh Dhillon ◽  
Sanha Kim ◽  
Bethany Lettiere ◽  
...  

1998 ◽  
Vol 120 (2) ◽  
pp. 365-370 ◽  
Author(s):  
K. H. Haddad ◽  
F. B. Cheung

Steady-state nucleate boiling heat transfer experiments in saturated and subcooled water were conducted. The heating surface was a 0.305 m hemispherical aluminum vessel heated from the inside with water boiling on the outside. It was found that subcooling had very little effect on the nucleate boiling curve in the high heat flux regime where latent heat transport dominated. On the other hand, a relatively large effect of subcooling was observed in the low-heat-flux regime where sensible heat transport was important. Photographic records of the boiling phenomenon and the bubble dynamics indicated that in the high-heat-flux regime, boiling in the bottom center region of the vessel was cyclic in nature with a liquid heating phase, a bubble nucleation and growth phase, a bubble coalescence phase, and a large vapor mass ejection phase. At the same heat flux level, the size of the vapor masses was found to decrease from the bottom center toward the upper edge of the vessel, which was consistent with the increase observed in the critical heat flux in the flow direction along the curved heating surface.


2016 ◽  
Vol 61 ◽  
pp. 127-139 ◽  
Author(s):  
Jure Petkovsek ◽  
Yi Heng ◽  
Matevz Zupancic ◽  
Henrik Gjerkes ◽  
Franc Cimerman ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document