scholarly journals Research and development of thick rubber bearing for SFR (Design formulas for thick rubber bearing based on static loading test utilized scale model)

2017 ◽  
Vol 83 (852) ◽  
pp. 17-00050-17-00050 ◽  
Author(s):  
Tsuyoshi FUKASAWA ◽  
Shigeki OKAMURA ◽  
Tomohiko YAMAMOTO ◽  
Nobuchika KAWASAKI ◽  
Satoru INABA ◽  
...  
Author(s):  
Bengt Fellenius

Results of a static loading test were used together with soil exploration records in a survey comprising analysis of the test records and estimating settlement of piled foundation to support a pipe rack. The test pile was a strain-gage instrumented, 400-mm diameter, precast, prestressed concrete pile driven into a clay and silt deposit to 25 m embedment. Two main issues were expected to be addressed by the survey participants: First, realization that the strain records were affected by presence of residual force in the pile and, second, calculation of the settlement of the piled foundation expected from the foundation load. A total of 52 submissions were received from 20 different countries. Only 12 of the submissions realized the presence of residual force. Most submissions reported a calculated settlement of the piled foundations ranging from 10 mm through 50 mm; however, 11 reported values between 60 and 200 mm. Surprisingly, only 20 submissions reported ground surface settlement close to the 200-mm value resulting from text-book analysis based on the available information. The subsequent construction of the piled foundations coincided with placing a fill across the site and lowering of the groundwater table, thus, causing a general subsidence.


Author(s):  
Askar Zh. Zhussupbekov ◽  
Yoshinori Iwasaki ◽  
Abdulla R. Omarov

At the present time, in Astana city is going on works by construction public transport system LRT (Light Railway Transport). LRT is an overhead road with two railway lines. The first stage of construction is including construction of overhead road (bridge) with 22,4 km length and 18 stations. The foundation of bridge is the bored piles with cross-section 1.0HL5 m and length 8-КЗ 5 m. In these conditions, very important to control integrity of concrete body of each bored piles. For checking integrity- applying two methods - Low Strain Method and Cross-Hole Sonic Logging. The aim of this paper is to discuss the advantages and disadvantages of each method using the examples of a real application. The article presents loading tests of large diameter and deep boring piles on the construction site in new capital city of the Republic of Kazakhstan. Finally, some recommendations for testmg methods suitable for problematical ground conditions of Kazakhstan are introduced. Traditionally, pile load tests in Kazakhstan are carried out using static loading test methods. Static pile loading test is the most reliable method to obtain the load-settlement relation of piles. Results of static pile tests using the static compression loading test (by ASTM). static loading test (by GOST) and bi-direction static loading test (by ASTM) methods are presented in this paper. Experienced bored piles with length of 31.5 m. diameter 1000 mm. Hereafter the results of underground testmg by the piles with the methods of vertical static tests of SLT. BDSLT and SCLT are presented, which had been made on Expo 2017 projects, buildings of Pavilion m Astana. Kazakhstan.


2016 ◽  
Vol 21 (5) ◽  
pp. 04016003 ◽  
Author(s):  
Julien Michels ◽  
Michał Staśkiewicz ◽  
Christoph Czaderski ◽  
Renata Kotynia ◽  
Yunus Emre Harmanci ◽  
...  

2008 ◽  
Vol 64 (2) ◽  
pp. 383-402 ◽  
Author(s):  
Hidetoshi NISHIOKA ◽  
Masayuki KODA ◽  
Masaru TATEYAMA ◽  
Naoyuki KITA ◽  
Junichi HIRAO ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document