residual force
Recently Published Documents


TOTAL DOCUMENTS

144
(FIVE YEARS 42)

H-INDEX

24
(FIVE YEARS 7)

PeerJ ◽  
2022 ◽  
Vol 10 ◽  
pp. e12729
Author(s):  
Jasmin Frischholz ◽  
Brent J. Raiteri ◽  
Andrew G. Cresswell ◽  
Daniel Hahn

Background Following stretch of an active muscle, muscle force is enhanced, which is known as residual force enhancement (rFE). As earlier studies found apparent corticospinal excitability modulations in the presence of rFE, this study aimed to test whether corticospinal excitability modulations contribute to rFE. Methods Fourteen participants performed submaximal plantar flexion stretch-hold and fixed-end contractions at 30% of their maximal voluntary soleus muscle activity in a dynamometer. During the steady state of the contractions, participants either received subthreshold or suprathreshold transcranial magnetic stimulation (TMS) of their motor cortex, while triceps surae muscle responses to stimulation were obtained via electromyography (EMG), and net ankle joint torque was recorded. B-mode ultrasound imaging was used to confirm muscle fascicle stretch during stretch-hold contractions in a subset of participants. Results Following stretch of the plantar flexors, an average rFE of 7% and 11% was observed for contractions with subthreshold and suprathreshold TMS, respectively. 41–46 ms following subthreshold TMS, triceps surae muscle activity was suppressed by 19–25%, but suppression was not significantly different between stretch-hold and fixed-end contractions. Similarly, the reduction in plantar flexion torque following subthreshold TMS was not significantly different between contraction conditions. Motor evoked potentials, silent periods and superimposed twitches following suprathreshold TMS were also not significantly different between contraction conditions. Discussion As TMS of the motor cortex did not result in any differences between stretch-hold and fixed-end contractions, we conclude that rFE is not linked to changes in corticospinal excitability.


2021 ◽  
Vol 16 (59) ◽  
pp. 35-48
Author(s):  
Amar Behtani ◽  
Samir Tiachacht ◽  
Tawfiq Khatir ◽  
Samir Khatir ◽  
Magd Abdel Wahab ◽  
...  

The strongest point about damage identification based on the dynamic measurements, is the ability perform structural health evaluation globally. Researchers in the last few years payed more attention to damage indicators based on modal analysis using either frequencies, mode shapes, or Frequency Response Functions (FRFs). This paper presents a new application of damage identification in a cross-ply (0°/90°/0°) laminated composite plate based on Force Residual Method (FRM) damage indicator. Considering single and multiple damages with different damage levels. As well as investigating the SSSS and CCCC boundary conditions effect on the estimation accuracy. Moreover, a white Gaussian noise is introduced to test the challenge the technique. The results show that the suggested FRM indicator provides accurate results under different boundary conditions. Favouring the SSSS boundary condition than the CCCC for 3% noise.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Adam Krasiński ◽  
Mateusz Wiszniewski

Abstract Occurrence of the so-called residual force of an unknown value significantly disturbs interpretation of static load tests performed on piles equipped with additional measuring instruments. Screw displacement piles are the piling technology in which the residual force phenomenon is very common. Its formation mechanism is closely related to the installation method of this type of piles, which initiates generation of negative pile skin friction without any additional external factors. Knowledge of the value and distribution of a residual force (trapped in a pile shaft before starting the load test) is a necessary condition for the proper interpretation of instrumented pile test results. In this article, a clear and easy-to-use method of residual force identification, based on the analysis of shaft deformations recorded during pile unloading is presented. The method was successfully verified on two pile examples and proved to be effective and practical.


Author(s):  
Fayez Elkholy ◽  
Silva Schmidt ◽  
Falko Schmidt ◽  
Masoud Amirkhani ◽  
Bernd G. Lapatki

Abstract Background This in vitro study investigated the effect of three distinct daily loading/unloading cycles on force delivery during orthodontic aligner therapy. The cycles were applied for 7 days and were designed to reflect typical clinical aligner application scenarios. Materials and methods Flat polyethylene terephthalate glycol (PET-G) specimens (Duran®, Scheu Dental, Iserlohn, Germany) with thicknesses ranging between 0.4 and 0.75 mm were tested in a three-point-bending testing machine. Measurements comprised loading/unloading intervals of 12 h/12 h, 18 h/6 h, and 23 h/1 h, and specimens were exposed to bidistilled water during loading to simulate intraoral conditions. Results A very large decay in force for the PET‑G specimens could already be observed after the first loading period, with significantly different residual force values of 24, 20, and 21% recorded for the 12 h/12 h, 18 h/6 h, and 23 h/1 h loading/unloading modes, respectively (Mann–Whitney U test, p < 0.01). In addition, further decays in force from the first to the last loading period at day 7 of 13.5% (12 h/12 h), 9.7% (18 h/6 h), and 8.4% (23 h/1 h) differed significantly among the three distinct loading modes (Mann–Whitney U test, p < 0.01). Conclusion Although the initial material stiffness of PET‑G is relatively high, the transmission of excessive forces is attenuated by the high material-related force decay already within a few hours after intraoral insertion.


2021 ◽  
Vol 22 (16) ◽  
pp. 8526
Author(s):  
Venus Joumaa ◽  
Ian C. Smith ◽  
Atsuki Fukutani ◽  
Timothy R. Leonard ◽  
Weikang Ma ◽  
...  

Our purpose was to use small-angle X-ray diffraction to investigate the structural changes within sarcomeres at steady-state isometric contraction following active lengthening and shortening, compared to purely isometric contractions performed at the same final lengths. We examined force, stiffness, and the 1,0 and 1,1 equatorial and M3 and M6 meridional reflections in skinned rabbit psoas bundles, at steady-state isometric contraction following active lengthening to a sarcomere length of 3.0 µm (15.4% initial bundle length at 7.7% bundle length/s), and active shortening to a sarcomere length of 2.6 µm (15.4% bundle length at 7.7% bundle length/s), and during purely isometric reference contractions at the corresponding sarcomere lengths. Compared to the reference contraction, the isometric contraction after active lengthening was associated with an increase in force (i.e., residual force enhancement) and M3 spacing, no change in stiffness and the intensity ratio I1,1/I1,0, and decreased lattice spacing and M3 intensity. Compared to the reference contraction, the isometric contraction after active shortening resulted in decreased force, stiffness, I1,1/I1,0, M3 and M6 spacings, and M3 intensity. This suggests that residual force enhancement is achieved without an increase in the proportion of attached cross-bridges, and that force depression is accompanied by a decrease in the proportion of attached cross-bridges. Furthermore, the steady-state isometric contraction following active lengthening and shortening is accompanied by an increase in cross-bridge dispersion and/or a change in the cross-bridge conformation compared to the reference contractions.


2021 ◽  
Vol 9 (15) ◽  
Author(s):  
Florian K. Paternoster ◽  
Denis Holzer ◽  
Anna Arlt ◽  
Ansgar Schwirtz ◽  
Wolfgang Seiberl

Author(s):  
Daiani de Campos ◽  
Lucas B.R. Orssatto ◽  
Gabriel S. Trajano ◽  
Walter Herzog ◽  
Heiliane de Brito Fontana

2021 ◽  
pp. 103814
Author(s):  
Henrique Ferrolho ◽  
Wolfgang Merkt ◽  
Carlo Tiseo ◽  
Sethu Vijayakumar
Keyword(s):  

Author(s):  
Bengt Fellenius

Results of a static loading test were used together with soil exploration records in a survey comprising analysis of the test records and estimating settlement of piled foundation to support a pipe rack. The test pile was a strain-gage instrumented, 400-mm diameter, precast, prestressed concrete pile driven into a clay and silt deposit to 25 m embedment. Two main issues were expected to be addressed by the survey participants: First, realization that the strain records were affected by presence of residual force in the pile and, second, calculation of the settlement of the piled foundation expected from the foundation load. A total of 52 submissions were received from 20 different countries. Only 12 of the submissions realized the presence of residual force. Most submissions reported a calculated settlement of the piled foundations ranging from 10 mm through 50 mm; however, 11 reported values between 60 and 200 mm. Surprisingly, only 20 submissions reported ground surface settlement close to the 200-mm value resulting from text-book analysis based on the available information. The subsequent construction of the piled foundations coincided with placing a fill across the site and lowering of the groundwater table, thus, causing a general subsidence.