component position
Recently Published Documents


TOTAL DOCUMENTS

142
(FIVE YEARS 35)

H-INDEX

26
(FIVE YEARS 3)

2021 ◽  
Vol 10 (24) ◽  
pp. 5773
Author(s):  
Maciej J. K. Simon ◽  
Helen Crofts ◽  
Treny Sasyniuk ◽  
Kayla Johnston ◽  
Derek Plausinis ◽  
...  

Background: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. Methods: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior–posterior (AP) and superior–inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. Results: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (−19.4 ± 8.6° to −17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. Conclusion: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.


2021 ◽  
Vol 2 (10) ◽  
pp. 834-841
Author(s):  
Patrick B. O'Connor ◽  
Matthew T. Thompson ◽  
Christina I. Esposito ◽  
Nikola Poli ◽  
James McGree ◽  
...  

Aims Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined anteversion on risk of impingement with changing pelvic position. Methods We used a virtual hip ROM (vROM) tool to investigate whether there is an ideal functional combined anteversion for reduced risk of hip impingement. We collected PT information from functional lateral radiographs (standing and sitting) and a supine CT scan, which was then input into the vROM tool. We developed a novel vROM scoring system, considering both seated flexion and standing extension manoeuvres, to quantify whether hips had limited ROM and then correlated the vROM score to component position. Results The vast majority of THA planned with standing combined anteversion between 30° to 50° and sitting combined anteversion between 45° to 65° had a vROM score > 99%, while the majority of vROM scores less than 99% were outside of this zone. The range of PT in supine, standing, and sitting positions varied widely between patients. Patients who had little change in PT from standing to sitting positions had decreased hip vROM. Conclusion It has been shown previously that an individual’s unique spinopelvic alignment influences functional cup anteversion. But functional combined anteversion, which also considers stem position, should be used to identify an ideal THA position for impingement-free ROM. We found a functional combined anteversion zone for THA that may be used moving forward to place total hip components. Cite this article: Bone Jt Open 2021;2(10):834–841.


2021 ◽  
Vol 4 (9) ◽  
pp. 56-60
Author(s):  
Caitlin Barrett ◽  
Jillian Glasser ◽  
Brooke Barrow ◽  
Dioscaris Garcia ◽  
Valentin Antoci

2021 ◽  
Vol 11 (7) ◽  
pp. 662
Author(s):  
Kim Huber ◽  
Bernhard Christen ◽  
Sarah Calliess ◽  
Tilman Calliess

Introduction: Image-based robotic assistance appears to be a promising tool for individualizing alignment in total knee arthroplasty (TKA). The patient-specific model of the knee enables a preoperative 3D planning of component position. Adjustments to the individual soft-tissue situation can be done intraoperatively. Based on this, we have established a standardized workflow to implement the idea of kinematic alignment (KA) for robotic-assisted TKA. In addition, we have defined limits for its use. If these limits are reached, we switch to a restricted KA (rKA). The aim of the study was to evaluate (1) in what percentage of patients a true KA or an rKA is applicable, (2) whether there were differences regarding knee phenotypes, and (3) what the differences of philosophies in terms of component position, joint stability, and early patient outcome were. Methods: The study included a retrospective analysis of 111 robotic-assisted primary TKAs. Based on preoperative long leg standing radiographs, the patients were categorized into a varus, valgus, or neutral subgroup. Initially, all patients were planned for KA TKA. When the defined safe zone had been exceeded, adjustments to an rKA were made. Intraoperatively, the alignment of the components and joint gaps were recorded by robotic software. Results and conclusion: With our indication for TKA and the defined boundaries, “only” 44% of the patients were suitable for a true KA with no adjustments or soft tissue releases. In the varus group, it was about 70%, whereas it was 0% in the valgus group and 25% in the neutral alignment group. Thus, significant differences with regard to knee morphotypes were evident. In the KA group, a more physiological knee balance reconstructing the trapezoidal flexion gap (+2 mm on average laterally) was seen as well as a closer reconstruction of the surface anatomy and joint line in all dimensions compared to rKA. This resulted in a higher improvement in the collected outcome scores in favor of KA in the very early postoperative phase.


2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Osamu Tanifuji ◽  
Tomoharu Mochizuki ◽  
Hiroshi Yamagiwa ◽  
Takashi Sato ◽  
Satoshi Watanabe ◽  
...  

Abstract Purpose The purpose of this study was to evaluate the post-operative three-dimensional (3D) femoral and tibial component positions in total knee arthroplasty (TKA) by the same co-ordinates’ system as for pre-operative planning and to compare it with a two-dimensional (2D) evaluation. Materials and methods Sixty-five primary TKAs due to osteoarthritis were included. A computed tomography (CT) scan of the femur and tibia was obtained and pre-operative 3D planning was performed. Then, 3D and 2D post-operative evaluations of the component positions were performed. KneeCAS (LEXI, Inc., Tokyo, Japan), a lower-extremity alignment assessment system, was used for the 3D post-operative evaluation. Standard short-knee radiographs were used for the 2D post-operative evaluation. Differences between the pre-operative planning and post-operative coronal and sagittal alignment of components were investigated and compared with the results of the 3D and 2D evaluations. Results According to the 3D evaluation, the difference between the pre-operative planning and actual post-operative sagittal alignment of the femoral component and the coronal and sagittal alignments of the tibial component were 2.6° ± 1.8°, 2.2° ± 1.8° and 3.2° ± 2.4°, respectively. Using the 2D evaluation, they were 1.9° ± 1.5°, 1.3° ± 1.2° and 1.8° ± 1.4°, making the difference in 3D evaluation significantly higher (p = 0.013, = 0.003 and < 0.001). For the sagittal alignment of the femoral component and the coronal and sagittal alignment of the tibial component, the outlier (> ± 3°) ratio for the 3D evaluation was also significantly higher than that of the 2D evaluation (p < 0.001, = 0.009 and < 0.001). Conclusions The difference between the pre-operative planning and post-operative component alignment in the 3D evaluation is significantly higher than that of the 2D, even if the same cases have been evaluated. Two-dimensional evaluation may mask or underestimate the post-operative implant malposition. Three-dimensional evaluation using the same co-ordinates’ system as for pre-operative planning is necessary to accurately evaluate the post-operative component position.


Author(s):  
Ulrich Bechler ◽  
Bernhard Springer ◽  
Kilian Rueckl ◽  
Tim Rolvien ◽  
Friedrich Boettner
Keyword(s):  

Author(s):  
Junren Zhang ◽  
Wofhatwa Solomon Ndou ◽  
Nathan Ng ◽  
Paul Gaston ◽  
Philip M. Simpson ◽  
...  

AbstractThis systematic review and meta-analysis were conducted to compare the accuracy of component positioning, alignment and balancing techniques employed, patient-reported outcomes, and complications of robotic-arm assisted total knee arthroplasty (RATKA) with manual TKA (mTKA) and the associated learning curve. Searches of PubMed, Medline and Google Scholar were performed in October 2020 using PRISMA guidelines. Search terms included “robotic”, “knee” and “arthroplasty”. The criteria for inclusion were published clinical research articles reporting the learning curve for RATKA and those comparing the component position accuracy, alignment and balancing techniques, functional outcomes, or complications with mTKA. There were 198 articles identified, following full text screening, 16 studies satisfied the inclusion criteria and reported the learning curve of rTKA (n=5), component positioning accuracy (n=6), alignment and balancing techniques (n=7), functional outcomes (n=7), or complications (n=5). Two studies reported the learning curve using CUSUM analysis to establish an inflexion point for proficiency which ranged from 7 to 11 cases and there was no learning curve for component positioning accuracy. The meta-analysis showed a significantly lower difference between planned component position and implanted component position, and the spread was narrower for RATKA compared with the mTKA group (Femur coronal: mean 1.31, 95% confidence interval (CI) 1.08–1.55, p<0.00001; Tibia coronal: mean 1.56, 95% CI 1.32–1.81, p<0.00001). Three studies reported using different alignment and balancing techniques between mTKA and RATKA, two studies used the same for both group and two studies did not state the methods used in their RATKA groups. RATKA resulted in better Knee Society Score compared to mTKA in the short-to-mid-term follow up (95%CI [− 1.23,  − 0.51], p=0.004). There was no difference in arthrofibrosis, superficial and deep infection, wound dehiscence, or overall complication rates. RATKA demonstrated improved accuracy of component positioning and patient-reported outcomes. The learning curve of RATKA for operating time was between 7 and 11 cases. Future well-powered studies on RATKAs should report on the knee alignment and balancing techniques utilised to enable better comparisons on which techniques maximise patient outcomes.Level of evidence III.


Author(s):  
Xuedong Sun ◽  
Xueli Zhao ◽  
Licheng Zhou ◽  
Zheng Su

Abstract Background This study was performed to compare the advantage and disadvantage of posterolateral approach (PLA) and direct anterior approach (DAA) in total hip arthroplasty (THA). Methods Relevant trials were identified via a search of the Cochrane Central Register of Controlled Trials and PubMed from inception to 1 June 2019. A meta-analysis was performed to compare postoperative perioperative and radiographic outcomes between DAA and PLA in THA with respect to the hospital stay, blood loss, incision length, operative time, complications, and femoral and cup component position. The Harris Hip Score (HHS) was also assessed before and after 6 months postoperatively. Results Nine eligible studies involving 22698 adult patients (DAA group, n = 2947; PLA group, n = 19751) were identified for analysis. Compared with the PLA group, the DAA group had shorter hospital stay and achieved better HHS within 6 months after operation (P < 0.05), but the HHS was no significant differences between the two groups over 6 months (P > 0.05). The DAA group had significantly longer operative time, more blood loss, and complications than the PLA group (P < 0.05). In addition, the femoral component positioned in neutral and cup component inclination angle was comparable between both groups (P > 0.05); however, cup component anteversion angle was significantly larger in the PLA group (P < 0.05). Conclusion Patients in the DAA group had higher HHS within 6 months and shorter hospital stay. The DAA could offer rapid early functional recovery after THA compared with the PLA. However, the DAA group often required longer operative time and had more blood loss. Furthermore, there was a higher early complication rate. Therefore, we believe that the direct anterior approach was a more difficult technique. The surgeon should be a well-trained joint surgeon with extensive prior hip replacement experience before performing THA through a DAA, and DAA was not suitable for beginners performing THA. In addition, we did not observe the difference with regard to the femoral component position and cup component inclination angle except for the smaller cup component anteversion angle in DAA group.


Sign in / Sign up

Export Citation Format

Share Document