scholarly journals The hidden costs of metal-on-metal hip resurfacing: the financial and logistical implications of a change in hospital follow-up policy

2013 ◽  
Vol 95 (3) ◽  
pp. 88-91
Author(s):  
J Lloyd ◽  
I Starks ◽  
T Wainwright ◽  
R Middleton

Metal-on-metal (MoM) hip resurfacings (HRs) and large head total hip replacements (LHTHRs) were perceived by many as a surgical revolution, with clear advantages over the traditional metal-on-polyethylene total hip replacement (THR). This is especially the case for younger, active individuals in whom conventional THR has been associated with higher rates of aseptic loosening. In addition to less bearing surface wear, frequently cited advantages for HR include the preservation of femoral bone stock, lower dislocation rates, and superior function and activity scores.

2019 ◽  
Vol 4 (6) ◽  
pp. 423-429 ◽  
Author(s):  
Bart G. Pijls ◽  
Jennifer M. T. A. Meessen ◽  
Keith Tucker ◽  
Susanna Stea ◽  
Liza Steenbergen ◽  
...  

The purpose of this paper is to determine the prevalence of metal-on-metal (MoM) total hip replacement (THR) in European registries, to assess the incidence of revision surgery and to describe the national follow-up guidelines for patients with MoM THR including resurfacings. Eleven registries of the Network of Orthopaedic Registries of Europe (NORE) participated totalling 54 434 resurfacings and 58 498 large stemmed MoM THRs. The resurfacings and stemmed large head MoM had higher pooled revision rates at five years than the standard total hip arthroplasties (THA): 6.0%, 95% confidence interval (CI) 5.3 to 6.8 for resurfacings; 6.9%, 95% CI 4.4 to 9.4 for stemmed large head MoM; and 3.0%, 95% CI 2.5 to 3.6 for conventional THA. The resurfacings and stemmed large head MoM had higher pooled revision rates at ten years than the standard THAs: 12.1%, 95% CI 11.0 to 13.3 for resurfacings; 15.5%, 95% CI 9.0 to 22 for stemmed large head MoM; and 5.1%, 95% CI 3.8 to 6.4 for conventional THA. Although every national registry reports slightly different protocols for follow-up, these mostly consist of annual assessments of cobalt and chromium levels in blood and MRI (MARS) imaging. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180078


2013 ◽  
Vol 31 (11) ◽  
pp. 1677-1685 ◽  
Author(s):  
Ashley K. Matthies ◽  
Radu Racasan ◽  
Paul Bills ◽  
Liam Blunt ◽  
Suzie Cro ◽  
...  

2007 ◽  
Vol 2 (3-4) ◽  
pp. 178-185 ◽  
Author(s):  
J. -Y. Lazennec ◽  
P. Boyer ◽  
J. Poupon ◽  
M. -A. Rousseau ◽  
F. Laude ◽  
...  

1978 ◽  
Vol 7 (2) ◽  
pp. 107-110 ◽  
Author(s):  
H. S. Dobbs

The paper reports on the incidence of fracture of the femoral component of total hip replacements in patients at the Royal National Orthopaedic Hospital over the period 1963-1976. The average incidence of fracture was approximately 0.2 per cent per year for air melt air cast cobalt chrome components. For vacuum melt vacuum cast components there were no fractures, but because of the small number of insertions with a long follow-up period, this result could have been fortuitous. There was a suggestion that the fracture rate increased with time, but even 0.2 per cent is considered too high.


2013 ◽  
Vol 472 (2) ◽  
pp. 564-571 ◽  
Author(s):  
Nader A. Nassif ◽  
Danyal H. Nawabi ◽  
Kirsten Stoner ◽  
Marcella Elpers ◽  
Timothy Wright ◽  
...  

2017 ◽  
Vol 14 (1) ◽  
pp. 108-114 ◽  
Author(s):  
Amit Atrey ◽  
Alister Hart ◽  
Nasir Hussain ◽  
Jonathon Waite ◽  
Andrew J. Shepherd ◽  
...  

2017 ◽  
Vol 7 (2) ◽  
Author(s):  
Richard Barker Cook ◽  
Jeremy M. Latham ◽  
Robert J.K. Wood

Using a femoral head from one manufacturer on the stem of another manufacturer poses the risk that the taper interface between the components may not contact correctly and the performance of the joint will be impaired. The cohorts in this study are a combination of modular Birmingham Hip Resurfacing (BHR) and Adept femoral heads on CPT stems. The study reviews the geometry of the taper interfaces to establish if the taper clearance angles was outside of the normal range for other taper interfaces. In addition the rates of material loss from the bearings and taper and a ranking of the stem damage were reviewed to determine if the levels of loss were above that seen for other similar joints. The material loss analysis demonstrated that the rates or levels of loss from the bearings, taper and stem were no different to levels published for manufacturer matched joints and in many cases were lower. The results demonstrate that the taper clearance angles for the mixed manufacturer joints (BHR-CPT: 0.067 to -0.116, Adept-CPT: 0.101 to -0.056) were within the range of other studies and manufacturer matched clearances (0.134 to -0.149).Using components from different manufacturers has not in this instance increased the level of material loss from the joints, when compared to other similar manufacturer matched joints.