Development of In-Service Inspection Priorities for Pressurized Water Reactor High-Pressure Injection System Components

1994 ◽  
Vol 106 (1) ◽  
pp. 110-124 ◽  
Author(s):  
Truong V. Vo ◽  
Doyle R. Edwards
Author(s):  
J. Pottorf ◽  
S. M. Bajorek

A WCOBRA/TRAC model of an evolutionary pressurized water reactor with direct vessel injection was constructed using publicly available information and a hypothetical double-ended guillotine break of a cold leg pipe was simulated. The model is an approximation of a ABB/Combustion Engineering System 80+ pressurized water reactor (PWR). WCOBRA/TRAC is the thermal-hydraulics code approved by the U.S. Nuclear Regulatory Commission for use in realistic large break LOCA analyses of Westinghouse 3- and 4-loop PWRs and the AP600 passive design. The AP600 design uses direct vessel injection, and the applicability of WCOBRA/TRAC to such designs is supported by comparisons to appropriate test data. This study extends the application of WCOBRA/TRAC to the investigation of the predicted behavior of direct vessel injection in an evolutionary design. A series of large break LOCA simulations were performed assuming a core power of 3914 MWt, and Technical Specification limits of 2.5 on total peaking factor and 1.7 on hot channel enthalpy rise factor. Two cladding temperature peaks were predicted during reflood, one following bottom of core recovery and a second caused by saturated boiling of water in the downcomer. This behavior is consistent with prior WCOBRA/TRAC calculations for some Westinghouse PWRs. The simulation results are described, and the sensitivity to failure assumptions for the safety injection system is presented.


2005 ◽  
Vol 128 (2) ◽  
pp. 434-445 ◽  
Author(s):  
Andrea E. Catania ◽  
Alessandro Ferrari ◽  
Michele Manno ◽  
Ezio Spessa

A general conservative numerical model for the simulation of transmission-line unsteady fluid dynamics has been developed and applied to high-pressure injection systems. A comprehensive thermodynamic approach for modeling acoustic cavitation, i.e., cavitation induced by wave propagation, was proposed on the basis of a conservative homogeneous two-phase barotropic flow model of a pure liquid, its vapor, and a gas, both dissolved and undissolved. A physically consistent sound speed equation was set in a closed analytical form of wide application. For the pure-liquid flow simulation outside the cavitation regions, or in the absence of these, temperature variations due to compressibility effects were taken into account, for the first time in injection system simulation, through a thermodynamic relation derived from the energy equation. Nevertheless, in the cavitating regions, an isothermal flow was retained consistently with negligible macroscopic thermal effects due to vaporization or condensation, because of the tiny amounts of liquid involved. A novel implicit, conservative, one-step, symmetrical, and trapezoidal scheme of second-order accuracy was employed to solve the partial differential equations governing the pipe flow. It can also be enhanced at a high-resolution level. The numerical model was applied to wave propagation and cavitation simulation in a high-pressure injection system of the pump-line-nozzle type for light and medium duty vehicles. The system was relevant to model assessment because, at part loads, it presented cavitating flow conditions that can be considered as severe, at least for a diesel injection system. The predicted time histories of pressure at two pipe locations and of injector needle lift were compared to experimental results, substantiating the validity and robustness of the developed conservative model in simulating acoustic cavitation inception and desinence with great accuracy degree. Cavitation transients and the flow discontinuities induced by them were numerically predicted and analyzed.


Author(s):  
Shinya Miyata ◽  
Satoru Kamohara ◽  
Wataru Sakuma ◽  
Hiroaki Nishi

In typical pressurized water reactor (PWR), to cope with beyond design basis events such as station black out (SBO) or small break loss of coolant accident with safety injection system failure, injection from accumulator sustains core cooling by compensating for loss of coolant. Core cooling is sustained by single- or two-phase natural circulation or reflux condensation depending on primary coolant mass inventory. Behavior of the natural circulation in PWR has been investigated in the facilities such as Large Scale Test Facility (LSTF) which is a full-height and full-pressure and thermal-hydraulic simulator of typical four-loop PWR. Two steady-state natural circulation tests were conducted in LSTF at both high and low pressure. These two tests were conducted changing the primary mass inventory as a test parameter, while keeping the other parameters such as core power, steam generator (SG) pressure, and steam generator water level as they are. Mitsubishi Heavy Industries (MHI) plans new natural circulation tests to cover wider range of core power and pressure as test-matrix (including the previous LSTF tests) to validate applicability of the model in wider range of core power and pressure conditions including the SBO conditions. In this paper, the previous LSTF natural circulation tests are reviewed and the new test plan will be described. Additionally, MHI also started a feasibility study to improve the steam generator tube and inlet/outlet plenum model using the M-RELAP5 code [4]. Newly developed model gives reasonable agreement with the previous LSTF tests and applies to the new test conditions. The feasibility findings will also be described in this paper.


Author(s):  
Andrea E. Catania ◽  
Alessandro Ferrari ◽  
Michele Manno ◽  
Ezio Spessa

A general conservative numerical model for simulation of transmission-line unsteady fluid-dynamics has been developed and applied to high-pressure injection systems. A comprehensive thermodynamic approach for modeling acoustic cavitation, i.e. cavitation induced by wave propagation, was proposed on the basis of a homogeneous barotropic mixture model of a pure liquid in equilibrium with its vapor and a gas, both dissolved and undissolved. For the pure liquid flow simulation outside the cavitation regions, or in the absence of these, temperature variations due to compressibility effects were taken into account, for the first time in injection system simulation, through a thermodynamic state equation which was derived from energy considerations. Nevertheless, in the cavitation regions, an isothermal flow was retained which is consistent with negligible thermal effects due to vaporization because of the tiny amounts of liquid involved. A novel implicit, conservative, one step, symmetrical and trapezoidal scheme of the second-order accuracy was applied to solve the hyperbolic partial differential equations governing the pipe flows. It can also be enhanced at a high-resolution level. The numerical model was applied to wave propagation and cavitation simulation in a high-pressure injection system of the pump-line-nozzle type for light and medium duty vehicles. The system was of relevance to the model assessment because it presented severely cavitating flow conditions. The predicted pressure time histories at two pipe locations and injector needle lift were compared to experimental results, substantiating the validity and robustness of the developed conservative model in simulating cavitation inception and desinence with great degree of accuracy. Cavitation transients and the flow discontinuities induced by them were numerically analyzed and discussed.


2014 ◽  
Vol 77 ◽  
pp. 48-64 ◽  
Author(s):  
Wei Li ◽  
Xiaoli Wu ◽  
Yapei Zhang ◽  
Deyou Ma ◽  
Yongzheng Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document