Performance analysis of zinc oxide-implemented lossy mode resonance-based optical fiber refractive index sensor utilizing thin film/nanostructure

2017 ◽  
Vol 56 (20) ◽  
pp. 5716 ◽  
Author(s):  
Sruthi Prasood Usha ◽  
Banshi Dhar Gupta
2018 ◽  
Vol 10 (3) ◽  
pp. 85 ◽  
Author(s):  
Marzena Hirsch

Optical fiber sensors of refractive index play important role in analysis of biological and chemical samples. This work presents a theoretical investigation of a spectral response of fiber optic microsphere with zinc-oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such structure for refractive index sensing. Microsphere is fabricated by optical fiber tapering method on the base of a single mode fiber. A numerical model is described and simulation was conducted to assess the influence of the ZnO layer deposition on a reflected signal. The results indicate that ZnO film improves the performance in terms of a potential application in refractive index sensor. Full Text: PDF ReferencesY. Qian, Y. Zhao, Q. Wu, Y. Yang, Review of salinity measurement technology based on optical fiber sensor, Sensors and Actuators B: Chemical, 260, 86–105 (2018). CrossRef M. Jędrzejewska-Szczerska, Response of a New Low-Coherence Fabry-Pérot Sensor to Hematocrit Levels in Human Blood, Sensors, 14, 4, 6965–6976, (2014). CrossRef F. Sequeira et al., Refractive Index Sensing with D-Shaped Plastic Optical Fibers for Chemical and Biochemical Applications, Sensors, 16, 12, 2119, (2016). CrossRef M. Jędrzejewska-Szczerska et al., ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Pérot interferometer, Sensors and Actuators A: Physical, 221, 88–94, (2015). CrossRef M. Hirsch, D. Majchrowicz, P. Wierzba, M. Weber, M. Bechelany, M. Jędrzejewska-Szczerska, Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors, Sensors, 17, 2, 261, (2017). CrossRef M. Hirsch, P. Wierzba, M. Jędrzejewska-Szczerska, Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study, Proc. SPIE 10161, 101610D (2016). CrossRef J. Pluciński, K. Karpienko, Fiber optic Fabry-Pérot sensors: modeling versus measurements results, Proc. SPIE 10034, 100340H (2016). CrossRef F. Goldsmith, Quasioptical systems: Gaussian beam quasioptical propagation and applications. (Piscataway, NJ: IEEE Press 1998). CrossRef


2021 ◽  
Vol 1879 (3) ◽  
pp. 032077
Author(s):  
Maher Khaleel Ibrahim ◽  
Shehab A Kadhim ◽  
Nabeil Ibrahim Fawaz

Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1028
Author(s):  
Na Zhao ◽  
Qijing Lin ◽  
Kun Yao ◽  
Fuzheng Zhang ◽  
Bian Tian ◽  
...  

The optical fiber temperature and refractive index sensor combined with the hollow needle structure for medical treatment can promote the standardization of traditional acupuncture techniques and improve the accuracy of body fluid analysis. A double-parameter sensor based on fiber Bragg grating (FBG) is developed in this paper. The sensor materials are selected through X-ray diffraction (XRD) analysis, and the sensor sensing principle is theoretically analyzed and simulated. Through femtosecond laser writing pure silica fiber, a high temperature resistant wavelength type FBG temperature sensor is obtained, and the FBG is corroded by hydrofluoric acid (HF) to realize a high-sensitivity intensity-type refractive index sensor. Because the light has dual characteristics of energy and wavelength, the sensor can realize simultaneous dual-parameter sensing. The light from the lead-in optical fiber is transmitted to the sensor and affected by temperature and refractive-index; then, the reflection peak is reflected back to the lead-out fiber by the FBG. The high temperature response and the refractive index response of the sensor were measured in the laboratory, and the high temperature characteristics of the sensor were verified in the accredited institute. It is demonstrated that the proposed sensor can achieve temperature sensing up to 1150 °C with the sensitivity of 0.0134 nm/°C, and refractive sensing over a refractive range of 1.333 to 1.4027 with the sensitivity of −49.044 dBm/RIU. The sensor features the advantages of two-parameter measurement, compact structure, and wide temperature range, and it exhibits great potential in acupuncture treatment.


Measurement ◽  
2021 ◽  
pp. 110287
Author(s):  
Nur Alia Sheh Omar ◽  
Ramli Irmawati ◽  
Yap Wing Fen ◽  
Ernee Noryana Muhamad ◽  
Faten Bashar Kamal Eddin ◽  
...  

2016 ◽  
Vol 16 (2) ◽  
pp. 355-358 ◽  
Author(s):  
Ning Jing ◽  
Chuanxin Teng ◽  
Fangda Yu ◽  
Guanjun Wang ◽  
Jie Zheng

2009 ◽  
Vol 9 (5) ◽  
pp. 525-532 ◽  
Author(s):  
Cathy Chung Chun Lam ◽  
Rajesh Mandamparambil ◽  
Tong Sun ◽  
Kenneth T. V. Grattan ◽  
Sreejith V. Nanukuttan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document