scholarly journals Handheld multispectral fluorescence lifetime imaging system for in vivo applications

2014 ◽  
Vol 5 (3) ◽  
pp. 921 ◽  
Author(s):  
Shuna Cheng ◽  
Rodrigo M. Cuenca ◽  
Boang Liu ◽  
Bilal H. Malik ◽  
Joey M. Jabbour ◽  
...  
2013 ◽  
Vol 19 (4) ◽  
pp. 791-798 ◽  
Author(s):  
Yinghua Sun ◽  
Jennifer E. Phipps ◽  
Jeremy Meier ◽  
Nisa Hatami ◽  
Brian Poirier ◽  
...  

AbstractA clinically compatible fluorescence lifetime imaging microscopy (FLIM) system was developed. The system was applied to intraoperative in vivo imaging of head and neck squamous cell carcinoma (HNSCC). The endoscopic FLIM prototype integrates a gated (down to 0.2 ns) intensifier imaging system and a fiber-bundle endoscope (0.5-mm-diameter, 10,000 fibers with a gradient index lens objective 0.5 NA, 4-mm field of view), which provides intraoperative access to the surgical field. Tissue autofluorescence was induced by a pulsed laser (337 nm, 700 ps pulse width) and collected in the 460 ± 25 nm spectral band. FLIM experiments were conducted at 26 anatomic sites in ten patients during head and neck cancer surgery. HNSCC exhibited a weaker florescence intensity (~50% less) when compared with healthy tissue and a shorter average lifetime (τHNSCC = 1.21 ± 0.04 ns) than the surrounding normal tissue (τN = 1.49 ± 0.06 ns). This work demonstrates the potential of FLIM for label-free head and neck tumor demarcation during intraoperative surgical procedures.


2007 ◽  
Vol 6 (4) ◽  
pp. 7290.2007.00019 ◽  
Author(s):  
Moinuddin Hassan ◽  
Jason Riley ◽  
Victor Chernomordik ◽  
Paul Smith ◽  
Randall Pursley ◽  
...  

In this article, a fluorescence lifetime imaging system for small animals is presented. Data were collected by scanning a region of interest with a measurement head, a linear fiber array with fixed separations between a single source fiber and several detection fibers. The goal was to localize tumors and monitor their progression using specific fluorescent markers. We chose a near-infrared contrast agent, Alexa Fluor 750 (Invitrogen Corp., Carlsbad, CA). Preliminary results show that the fluorescence lifetime for this dye was sensitive to the immediate environment of the fluorophore (in particular, pH), making it a promising candidate for reporting physiologic changes around a fluorophore. To quantify the intrinsic lifetime of deeply embedded fluorophores, we performed phantom experiments to investigate the contribution of photon migration effects on observed lifetime by calculating the fluorescence intensity decay time. A previously proposed theoretical model of migration, based on random walk theory, is also substantiated by new experimental data. The developed experimental system has been used for in vivo mouse imaging with Alexa Fluor 750 contrast agent conjugated to tumor-specific antibodies (trastuzumab [Herceptin]). Three-dimensional mapping of the fluorescence lifetime indicates lower lifetime values in superficial breast cancer tumors in mice.


2014 ◽  
Vol 20 (13) ◽  
pp. 3531-3539 ◽  
Author(s):  
Yasaman Ardeshirpour ◽  
Victor Chernomordik ◽  
Moinuddin Hassan ◽  
Rafal Zielinski ◽  
Jacek Capala ◽  
...  

2020 ◽  
Author(s):  
Xingbo Yang ◽  
Daniel J. Needleman

AbstractMitochondria are central to metabolism and their dysfunctions are associated with many diseases1–9. Metabolic flux, the rate of turnover of molecules through a metabolic pathway, is one of the most important quantities in metabolism, but it remains a challenge to measure spatiotemporal variations in mitochondrial metabolic fluxes in living cells. Fluorescence lifetime imaging microscopy (FLIM) of NADH is a label-free technique that is widely used to characterize the metabolic state of mitochondria in vivo10–18. However, the utility of this technique has been limited by the inability to relate FLIM measurement to the underlying metabolic activities in mitochondria. Here we show that, if properly interpreted, FLIM of NADH can be used to quantitatively measure the flux through a major mitochondrial metabolic pathway, the electron transport chain (ETC), in vivo with subcellular resolution. This result is based on the use of a coarse-grained NADH redox model, which we test in mouse oocytes subject to a wide variety of perturbations by comparing predicted fluxes to direct biochemical measurements and by self-consistency criterion. Using this method, we discovered a subcellular spatial gradient of mitochondrial metabolic flux in mouse oocytes. We showed that this subcellular variation in mitochondrial flux correlates with a corresponding subcellular variation in mitochondrial membrane potential. The developed model, and the resulting procedure for analyzing FLIM of NADH, are valid under nearly all circumstances of biological interest. Thus, this approach is a general procedure to measure metabolic fluxes dynamically in living cells, with subcellular resolution.


2018 ◽  
Vol 38 (4) ◽  
pp. 966-974 ◽  
Author(s):  
Piotr Sawosz ◽  
Stanislaw Wojtkiewicz ◽  
Michal Kacprzak ◽  
Elzbieta Zieminska ◽  
Magdalena Morawiec ◽  
...  

2020 ◽  
Vol 8 (3) ◽  
pp. 034003
Author(s):  
Deborah S Barkauskas ◽  
Gregory Medley ◽  
Xiaowen Liang ◽  
Yousuf H Mohammed ◽  
Camilla A Thorling ◽  
...  

2019 ◽  
Vol 10 (15) ◽  
pp. 4227-4235 ◽  
Author(s):  
Yingying Ning ◽  
Shengming Cheng ◽  
Jing-Xiang Wang ◽  
Yi-Wei Liu ◽  
Wei Feng ◽  
...  

Lanthanide complex was successfully applied in the design of pH-responsive NIR τ probe for quantitative in vivo imaging.


2005 ◽  
Vol 59 (9) ◽  
pp. 1174-1181 ◽  
Author(s):  
Daniela Comelli ◽  
Gianluca Valentini ◽  
Rinaldo Cubeddu ◽  
Lucia Toniolo

We developed a combined procedure for the analysis of works of art based on a portable system for fluorescence imaging integrated with analytical measurements on microsamples. The method allows us to localize and identify organic and inorganic compounds present on the surface of artworks. The fluorescence apparatus measures the temporal and spectral features of the fluorescence emission, excited by ultraviolet (UV) laser pulses. The kinetic of the emission is studied through a fluorescence lifetime imaging system, while an optical multichannel analyzer measures the fluorescence spectra of selected points. The chemical characterization of the compounds present on the artistic surfaces is then performed by means of analytical measurements on microsamples collected with the assistance of the fluorescence maps. The previous concepts have been successfully applied to study the contaminants on the surface of Michelangelo's David. The fluorescence analysis combined with Fourier transform infrared (FT-IR) measurements revealed the presence of beeswax, which permeates most of the statue surface, and calcium oxalate deposits mainly arranged in vertical patterns and related to rain washing.


Sign in / Sign up

Export Citation Format

Share Document