scholarly journals Some simple rules for contrast, signal-to-noise and resolution in in-line x-ray phase-contrast imaging

2008 ◽  
Vol 16 (5) ◽  
pp. 3223 ◽  
Author(s):  
Timur E. Gureyev ◽  
Yakov I. Nesterets ◽  
Andrew W. Stevenson ◽  
Peter R. Miller ◽  
Andrew Pogany ◽  
...  
Author(s):  
P. C. Diemoz ◽  
M. Endrizzi ◽  
A. Bravin ◽  
I. K. Robinson ◽  
A. Olivo

Recently, we developed a theoretical model that can predict the signal-to-noise ratio for edge-like features in phase-contrast images. This model was then applied for the estimation of the sensitivity of three different X-ray phase-contrast techniques: propagation-based imaging, analyser-based imaging and grating interferometry. We show here how the same formalism can be used also in the case of the edge illumination (EI) technique, providing results that are consistent with those of a recently developed method for the estimation of noise in the retrieved refraction image. The new model is then applied to calculate, in the case of a given synchrotron radiation set-up, the optimum positions of the pre-sample aperture and detector edge to maximize the sensitivity. Finally, an example of the extremely high angular resolution achievable with the EI technique is presented.


2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Author(s):  
Jianheng Huang ◽  
Yaohu Lei ◽  
Xin Liu ◽  
Jinchuan Guo ◽  
Ji Li ◽  
...  

2021 ◽  
Vol 11 (7) ◽  
pp. 2971
Author(s):  
Siwei Tao ◽  
Congxiao He ◽  
Xiang Hao ◽  
Cuifang Kuang ◽  
Xu Liu

Numerous advances have been made in X-ray technology in recent years. X-ray imaging plays an important role in the nondestructive exploration of the internal structures of objects. However, the contrast of X-ray absorption images remains low, especially for materials with low atomic numbers, such as biological samples. X-ray phase-contrast images have an intrinsically higher contrast than absorption images. In this review, the principles, milestones, and recent progress of X-ray phase-contrast imaging methods are demonstrated. In addition, prospective applications are presented.


2021 ◽  
Vol 1787 (1) ◽  
pp. 012027
Author(s):  
S S Makarov ◽  
T A Pikuz ◽  
A V Buzmakov ◽  
A P Chernyaev ◽  
P Mabey ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document