Infrared Intensities of Liquids XX: The Intensity of the OH Stretching Band of Liquid Water Revisited, and the Best Current Values of the Optical Constants of H2O(l) at 25°C between 15,000 and 1 cm−1

1996 ◽  
Vol 50 (8) ◽  
pp. 1047-1057 ◽  
Author(s):  
John E. Bertie ◽  
Zhida Lan

The previously reported nonreproducibility of the intensity of the OH stretching band of liquid water has been explored. It was found that it can be eliminated in measurements with the Circle® multiple ATR cell by ensuring that the ATR rod is coaxial with the glass liquid holder. It was also found that normal laboratory temperature variations of a few degrees change the intensity by ⩽∼1% of the peak height. A new imaginary refractive index spectrum of water has been determined between 4000 and 700 cm1 as the average of spectra calculated from ATR spectra recorded by four workers in our laboratory over the past seven years. It was obtained under experimental and computational conditions superior to those used previously, but is only marginally different from the spectra reported in 1989. In particular, the integrated intensities of the fundamentals are not changed significantly from those reported in 1989. The available imaginary refractive index, k, values between 15,000 and 1 cm−1 have been compared. The values that are judged to be the most reliable have been combined into a recommended k spectrum of H2O(l) at 25 °C between 15,000 and 1 cm−1, from which the real refractive index spectrum has been calculated by Kramers–Kronig transformation. The recommended values of the real and imaginary refractive indices and molar absorption coefficients of liquid water at 25 ± 1 °C are presented in graphs and tables. The real and imaginary dielectric constants and the real and imaginary molar polarizabilities in this wavenumber range can be calculated from the tables. Conservatively estimated probable errors of the recommended k values are given. The precision with which the values can be measured in one laboratory and the relative errors between regions are, of course, far smaller than these probable errors. The recommended k values should be of considerable value as interim standard intensities of liquid water, which will facilitate the transfer of intensities between laboratories.

1994 ◽  
Vol 48 (1) ◽  
pp. 144-159 ◽  
Author(s):  
John E. Bertie ◽  
R. Norman Jones ◽  
Yoram Apelblat

Accurate infrared absorption intensities of liquid chlorobenzene at 25°C are presented. Their accuracy was estimated from the agreement between the intensities measured by different spectroscopists using different instruments in different laboratories and by different spectroscopists using the same instrument in the same laboratory. The spectra from different spectroscopists have been averaged, unweighted, to give intensity spectra of chlorobenzene that are presented as the best available. The results are presented as graphs and tables of the molar absorption coefficient, Em (ν˜), and the real and imaginary refractive indices, n(ν˜) and k(ν˜), between 4800 and 450 cm−1. The peak heights and the areas under the bands in the absorption index (imaginary refractive index) spectrum are reported, as are areas under the molar absorption coefficient spectrum. Absorption index, k(ν˜), and molar absorption coefficient, Em (ν˜), values are believed accurate to an average ±2.4% at the peaks of bands with kmax > 0.002 and ±3.3% at the peaks of bands with kmax < 0.002. In the baseline k(ν˜) is accurate to ∼ ±5% above 3000 cm−1 and ∼ ±2.5% below 3000 cm−1. The areas under bands in k(ν˜) and Em (ν˜) spectra for which kmax > 0.002 are accurate to ±1.3% on average. The real refractive index, n(ν˜), values are believed to be accurate to ±0.2%.


1994 ◽  
Vol 48 (2) ◽  
pp. 176-189 ◽  
Author(s):  
John E. Bertie ◽  
Shuliang L. Zhang

This paper reports infrared absorption intensities of liquid methanol- d, CH3OD, at 25°C, between 8000 and 350 cm−1 Measurements were made by multiple attenuated total reflection spectroscopy with the use of the CIRCLE cell, and by transmission spectroscopy with a variable-path-length cell with CaF2 windows. The results of these two methods agree excellently and were combined to yield an imaginary refractive index spectrum, k(ν˜) vs. ν˜, between 6187 and 350 cm−1. The imaginary refractive index spectrum was arbitrarily set to zero between 6187 and 8000 cm−1 where k is always less than 2 × 10−6, in order that the real refractive index can be calculated below 8000 cm−1 by Kramers-Krönig transformation. The results are reported as graphs and as tables of the real and imaginary refractive indices between 8000 and 350 cm−1, from which all other infrared properties of liquid methanol- d can be calculated. The accuracy is estimated to be ± 3% below 5900 cm−1 and ± 10% above 5900 cm−1 for the imaginary refractive index and better than ± 0.5% for the real refractive index. In order to obtain molecular information from the refractive indices, the spectrum of the imaginary polarizability multiplied by wavenumber, ν˜ vs. ν˜, was calculated under the assumption of the Lorentz local field. The area under this ν˜ spectrum was separated into the integrated intensities of different vibrations. Molecular properties were calculated from these integrated intensities—specifically, the transition moments and dipole moment derivatives of the molecules in the liquid, the latter under the harmonic approximation. The availability of the spectra of both CH3OH and CH3OD enables the integrated intensities and the molecular properties of the C-H, O-H, O-D, and C-O stretching and CH3 deformation vibrations to be determined with confidence to a few percent. Further work with isotopic molecules is needed to improve the reliability of the integrated intensities of the C-O-H(D) in-plane bending, H-C-O-H(D) torsion, and CH3 rocking vibrations.


1995 ◽  
Vol 49 (6) ◽  
pp. 840-851 ◽  
Author(s):  
John E. Bertie ◽  
Zhida Lan ◽  
R. Norman Jones ◽  
Yoram Apelblat

This is the last of four papers that present the detailed measnrements and results that led to the acceptance by the International Union of Pure and Applied Chemistry of Secondary Infrared Absorption Intensity Standards for liquids. In this paper accurate infrared absorption intensities of liquid dichloromethane at 25°C are presented. The accuracy was estimated from the ±1.5% average agreement of integrated intensities over specific wavenumber ranges between spectra measured by five spectroscopists in four laboratories. The use of data from different instruments in different laboratories has significantly included the effect of systematic instrumental errors. The spectra from the different spectroscopists have been averaged, unweighted, to give intensity spectra of dichloromethane that are presented as the best available. The results obtained agree with the only measurements that have been made against a primary standard, the estimated accuracy of which is about 5.5%. The spectra of the molar absorption coefficient and or the real and imaginary refractive indices are reported as tables and graphs between 6500 and 800 cm−1. Also reported are the peak heights and the areas under band groups in the molar absorption coefficient and imaginary refractive index spectra. The imaginary refractive index, k(ν˜), and molar absorption coefficient, Em(ν˜), values are believed to be accurate to an average ±2.3% over the 36 measured bands. The baseline k(ν˜) values are believed to be accurate to ∼8% below 6000 cm−1, ∼1% below 4500 cm−1, and ∼25% above 6000 cm−1, where the absorption is extremely weak. The areas under band groups in the k(ν˜) and Em(ν˜) spectra are believed to be accurate to 1.5% averaged over the 15 measured band groups and to 1.0% over the 10 band groups below 3600 cm−1. The real refractive index, n(ν˜), values are believed to be accurate to 0.2%.


1993 ◽  
Vol 47 (8) ◽  
pp. 1100-1114 ◽  
Author(s):  
John E. Bertie ◽  
Shuliang L. Zhang ◽  
Hans H. Eysel ◽  
Shipra Baluja ◽  
M. Khalique Ahmed

This paper reports infrared absorption intensities of liquid methanol at 25°C between 8000 and 2 cm−1. Measurements were made by attenuated total reflection spectroscopy by four different workers between 1984 and 1991, with the use of CIRCLE cells of two different lengths and with several different alignments of the cell in the instrument. Steps were taken to ensure that as few parameters as possible remained unchanged throughout the series of measurements, to try to reveal systematic errors. The reproducibility was better than ±2.5% in regions of significant absorption. In order to allow comparison between different methods, results of all methods were converted to real and imaginary refractive index spectra. Measurements were also made by transmission spectroscopy in regions of weak absorption, with results that agreed excellently with those from ATR. The ATR and transmission results were combined to give a spectrum between 7500 and 350 cm−1. This spectrum agreed excellently with literature results from 350 to 2 cm−1, and the two sets of measurements were combined to yield a spectrum from 7500 to 2 cm−1. The imaginary refractive index was arbitrarily set to zero between 7500 and 8000 cm−1, where it is always less than 2 × 10−6, in order that the real refractive index can be calculated below 8000 cm−1 by Kramers-Kronig transform. The results are reported as graphs and as tables of the real and imaginary refractive indices between 8000 and 2 cm−1, from which all other infrared properties of liquid methanol can be calculated. The accuracy is estimated to be ±3% below 5000 cm−1 and ±10% above 5000 cm−1 for the imaginary refractive index and better than ±0.5% for the real refractive index. To obtain molecular information from the measurements, one calculates the imaginary molar polarizability spectrum, [Formula: see text] vs. [Formula: see text], under the Lorentz local field assumption, and the area under [Formula: see text] bands is separated into contributions from different vibrations under several approximations. Much accuracy is lost in this process. The changes of the dipole moment during normal vibrations, and during OH, CH, and CO bond stretching and COH torsional motion, are presented.


1994 ◽  
Vol 48 (1) ◽  
pp. 127-143 ◽  
Author(s):  
John E. Bertie ◽  
R. Norman Jones ◽  
Yoram Apelblat ◽  
C. Dale Keefe

This paper presents accurate infrared absorption intensities of liquid toluene at 25°C. The accuracy is estimated from the agreement between the intensities measured by different spectroscopists using the same instrument in the same laboratory and also by different spectroscopists in different laboratories using instruments made by different manufacturers. The average agreement between integrated intensities over specific wavenumber ranges is about ±1.8%. The spectra from the different laboratories have been averaged, unweighted, to give intensity spectra of toluene that are presented as the best available. The use of data from different instruments in different laboratories has included the influence of systematic instrumental errors, so that the precision of the intensity data presented should be a better approximation to its accuracy than would be the case from an extensive study by one person on one instrument. The results obtained agree with the only measurements that have been made against a primary standard, the estimated accuracy of which is about 6%. The results are presented as graphs and tables of the molar absorption coefficient spectrum and the real and imaginary refractive index spectra between 6500 and 435 cm−1. The peak heights and the areas under the bands in the imaginary refractive index (i.e., absorption index) and molar absorption coefficient spectra are reported. The absorption index, k(ν˜), and molar absorption coefficient, Em (ν˜), values are believed to be accurate to an average ±2.5% at the peaks of 39 strong, medium, and weak bands and ±1.9% at the peaks of 51 very weak bands below 4100 cm−1. Above 4100 cm−1, 11 very weak bands have an average accuracy of ±1.3%. The baseline k(ν˜) values are accurate to between ±3 and ±10%. The areas under bands or band groups in k(ν˜) and εm (ν˜) spectra are accurate to 2.4% on average, or 1.2% for strong, medium, and weak band groups between 3150 and 775 cm−1 with 0.002 < kmax < 0.112. The real refractive index, n(ν˜), values are believed to be accurate to 0.2%.


1993 ◽  
Vol 47 (7) ◽  
pp. 891-911 ◽  
Author(s):  
John E. Bertie ◽  
R. Norman Jones ◽  
C. Dale Keefe

This paper presents the results of a study to obtain accurate infrared absorption intensities of liquid benzene at 25°C. To achieve this we have determined the agreement between the intensities measured by different spectroscopists using the same instrument in the same laboratory and also by different spectroscopists in different laboratories using instruments made by different manufacturers. The agreement between integrated intensities over specific wavenumber ranges has been found to average about 2%. The spectra from the different laboratories have been averaged, unweighted, to give intensity spectra of benzene that are presented as the best available. The use of data from different instruments in different laboratories has reduced the influence of systematic instrumental errors, so that the agreement presented should be a better approximation to the accuracy of the intensities than would be the case from an extensive study by one person on one instrument. The intensity data presented agree with the only measurements that have been made against a primary standard, the evaluated uncertainty of which is about 6%. The results are presented in both graphic and tabular forms as spectra of the molar absorption coefficient, Em(ν˜), (also called the molar absorptivity, ε, formerly the extinction coefficient) and the real and imaginary refractive indices, n(ν˜) and k(ν˜), between 6225 and 500 cm−1. The peak heights and the areas under the bands in the imaginary refractive index spectrum are reported, together with the peak heights and the areas under the bands in the molar absorption coefficient spectrum. Imaginary refractive index, k(ν˜), and molar absorption coefficient, Em(ν˜), values are believed accurate to an average ±2% at the peaks of stronger bands, ±3.5% at the peaks of the weaker bands below 4100 cm−1, and ±2.5% above 4100 cm−1. The baseline k(ν˜) values are accurate to ∼10% above 1200 cm−1 and 1% to 5% below 1200 cm−1. The areas under bands or band groups in k(ν˜) and Em(ν˜) spectra are accurate to 2% on average, or 1.5% when measured above a baseline for calibration purposes. The real refractive index, n(ν˜), values are believed accurate to 0.2%.


2013 ◽  
Vol 6 (6) ◽  
pp. 9623-9653
Author(s):  
C. Klein ◽  
A. Dabas

Abstract. Studies carried out in the late 1970s suggest a simple linear relationship exists in practice between the optical extinction in the thermal IR and the liquid water content (LWC) in fogs. Such a relationship opens the possibility to monitor the vertical profile of the LWC in fogs with a rather simple backscatter lidar. Little is known on how the LWC varies as a function of height and during the fog life cycle, so the new measurement technique would help understand fog physics and provide valuable data for improving the quality of fog forecasts. In the present article, the validity of the linear relationship is revisited at the light of recent observations of fog droplet size distributions measured with a combination of sensors covering a large range of droplet radii. In particular, large droplets (radius above 15 μm) are detected, which was not the case in the late 1970s. The results confirm the linear relationship still holds, at least for the mostly radiative fogs observed during the campaign. The impact of the precise value of the real and imaginary parts of the refractive index on the coefficient of the linear relationship is also studied. The usual practice considers droplets are made of pure water. This assumption is probably valid for big droplets, it may be questioned for small ones since droplets are formed from condensation nuclei of highly variable chemical composition. The study suggests the relationship is mostly sensitive to the real part of the refractive index and the sensitivity grows with the size of fog droplets. However, large fog droplets are more likely to have an index close to that of water since they are mainly composed of water.


Sign in / Sign up

Export Citation Format