scholarly journals A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip

PLoS ONE ◽  
2015 ◽  
Vol 10 (9) ◽  
pp. e0137891 ◽  
Author(s):  
S. R. Balakrishnan ◽  
U. Hashim ◽  
Subash C. B. Gopinath ◽  
P. Poopalan ◽  
H. R. Ramayya ◽  
...  
2008 ◽  
Vol 94 (2) ◽  
pp. 216-225 ◽  
Author(s):  
Marco Bianchessi ◽  
Sarah Burgarella ◽  
Marco Cereda

The development of new powerful applications and the improvement in fabrication techniques are promising an explosive growth in lab-on-chip use in the upcoming future. As the demand reaches significant levels, the semiconductor industry may enter in the field, bringing its capability to produce complex devices in large volumes, high quality and low cost. The lab-on-chip concept, when applied to medicine, leads to the point-of-care concept, where simple, compact and cheap instruments allow diagnostic assays to be performed quickly by untrained personnel directly at the patient's side. In this paper, some practical and economical considerations are made to support the advantages of point-of-care testing. A series of promising technologies developed by STMicroelectronics on lab-on-chips is also presented, mature enough to enter in the common medical practice. The possible use of these techniques for cancer research, diagnosis and treatment are illustrated together with the benefits offered by their implementation in point-of-care testing.


2016 ◽  
Vol 1 (1) ◽  
pp. 67-76 ◽  
Author(s):  
Robert D Nerenz ◽  
Jennifer R Bell ◽  
Nancy Montes de Oca ◽  
Joann Short ◽  
Theresa Mims ◽  
...  

Abstract Background Point-of-care (POC) urine qualitative human chorionic gonadotropin (hCG) devices are used to rapidly assess pregnancy status, but many of these devices are susceptible to false-negative results caused by increased concentrations of hCG β core fragment (hCGβcf) that does not contain hCGβcf. Methods Purified hCG was added to hCG-negative heparinized whole blood to generate samples with known hCG concentrations, and the resulting samples were used to evaluate device sensitivity, low-end reproducibility, high-dose hook effect, intermediate range performance, acceptable sample volume, acceptable hematocrit range, and lot-to-lot variation. Device performance was also prospectively evaluated in 40 pregnant and 40 nonpregnant women aged 18–44 years in a hospital-based clinic or an academic hospital emergency department. Results All device observations were positive using a whole blood sample containing a plasma hCG concentration of 2.2 × 106 IU/L, and all device observations were positive from18 IU/L to 1.2 × 103 IU/L and from 2.5 × 104 IU/L to 2.2 × 106 IU/L. Three invalid results were observed in the intermediate range because of decreased control line intensity. The minimum sample volume was 30 μL, and maximum hematocrit was 46%. In 40 pregnant and 40 nonpregnant women aged 18–44 years, the device generated 100% concordance with urine qualitative and plasma quantitative test results. Conclusions The ADEXUSDx™ hCG test demonstrates acceptable performance for the determination of pregnancy status using capillary fingerstick samples.


2009 ◽  
Vol 55 (7) ◽  
pp. 1389-1394 ◽  
Author(s):  
Ann M Gronowski ◽  
Mark Cervinski ◽  
Ulf-Håkan Stenman ◽  
Alison Woodworth ◽  
Lori Ashby ◽  
...  

Abstract Background: During pregnancy, human chorionic gonadotropin (hCG) immunoreactivity in urine consists of intact hCG as well as a number of hCG variants including the core fragment of hCGβ (hCGβcf). We identified 3 urine specimens with apparent false-negative results using the OSOM® hCG Combo Test (Genzyme Diagnostics) qualitative hCG device and sought to determine whether an excess of 1 of the fragments or variants might be the cause of the interference. Methods: We measured concentrations of hCG variants in the urine from 3 patients with apparent false-negative hCG results. Purified hCG variants were added to urines positive for hCG and tested using the OSOM, ICON® 25 hCG (Beckman Coulter), and hCG Combo SP® Brand (Cardinal Health) devices. Results: Dilution of these 3 urine samples resulted in positive results on the OSOM device. Quantification of hCG variants in each of the 3 patient urine specimens demonstrated that hCGβcf occurred in molar excess of intact hCG. Addition of purified hCGβcf to hCG-positive urines caused false-negative hCG results using the OSOM and ICON qualitative urine hCG devices. Conclusions: Increased concentrations of hCGβcf can cause false-negative results on the OSOM and ICON qualitative urine hCG devices. .


2015 ◽  
Vol 451 ◽  
pp. 240-246 ◽  
Author(s):  
Nicola Marziliano ◽  
Maria Francesca Notarangelo ◽  
Marco Cereda ◽  
Vittoria Caporale ◽  
Lucia Coppini ◽  
...  
Keyword(s):  

2021 ◽  
Vol 8 (3) ◽  
pp. 031313
Author(s):  
Aref Asghari ◽  
Chao Wang ◽  
Kyoung Min Yoo ◽  
Ali Rostamian ◽  
Xiaochuan Xu ◽  
...  

Endocrinology ◽  
1993 ◽  
Vol 133 (3) ◽  
pp. 1390-1397 ◽  
Author(s):  
S Birken ◽  
Y Chen ◽  
M A Gawinowicz ◽  
J W Lustbader ◽  
S Pollak ◽  
...  

Sensors ◽  
2019 ◽  
Vol 19 (8) ◽  
pp. 1917 ◽  
Author(s):  
Shane O’Sullivan ◽  
Zulfiqur Ali ◽  
Xiaoyi Jiang ◽  
Reza Abdolvand ◽  
M Selim Ünlü ◽  
...  

We review some emerging trends in transduction, connectivity and data analytics for Point-of-Care Testing (POCT) of infectious and non-communicable diseases. The patient need for POCT is described along with developments in portable diagnostics, specifically in respect of Lab-on-chip and microfluidic systems. We describe some novel electrochemical and photonic systems and the use of mobile phones in terms of hardware components and device connectivity for POCT. Developments in data analytics that are applicable for POCT are described with an overview of data structures and recent AI/Machine learning trends. The most important methodologies of machine learning, including deep learning methods, are summarised. The potential value of trends within POCT systems for clinical diagnostics within Lower Middle Income Countries (LMICs) and the Least Developed Countries (LDCs) are highlighted.