scholarly journals Risk factors associated with adverse events during endoscopic ultrasound-guided tissue sampling

PLoS ONE ◽  
2017 ◽  
Vol 12 (12) ◽  
pp. e0189347 ◽  
Author(s):  
Kwang Hyuck Lee ◽  
Eun Young Kim ◽  
Juhee Cho ◽  
Danbee Kang ◽  
Seungmin Bang ◽  
...  
2021 ◽  
Author(s):  
Mateus Pereira Funari ◽  
Igor Braga Ribeiro ◽  
Marcos Eduardo Lera dos Santos ◽  
Sergio Eiji Matuguma ◽  
Eduardo Guimarães Hourneaux de Moura

2020 ◽  
Vol 91 (6) ◽  
pp. AB299-AB300
Author(s):  
Yousef Elfanagely ◽  
Chung Sang Tse ◽  
Joao Filipe G. Monteiro ◽  
Lawrence Kogan ◽  
Harlan Rich ◽  
...  

2014 ◽  
Vol 36 (4) ◽  
pp. 307
Author(s):  
Maria Helena Barbosa ◽  
Karla Fabiana Nunes da Silva ◽  
Dieska Quintiliano Coelho ◽  
Jordânia Lumênia Tavares ◽  
Luciana Falcão da Cruz ◽  
...  

2020 ◽  
Vol 08 (11) ◽  
pp. E1664-E1672
Author(s):  
Saurabh Chandan ◽  
Babu P. Mohan ◽  
Shahab R. Khan ◽  
Lena L. Kassab ◽  
Suresh Ponnada ◽  
...  

Abstract Background and study aims Endoscopic ultrasound guided pancreatic duct drainage (EUS-PDD) is a minimal-invasive therapeutic option to surgery and in patients with failed endoscopic retrograde pancreatography (ERP). The aim of this review was to quantitatively appraise the clinical outcomes of EUS-PDD by meta-analysis methods. Methods We searched multiple databases from inception through March 2020 to identify studies that reported on EUS-PDD. Pooled rates of technical success, successful drainage of pancreatic duct, clinical success, and adverse events were calculated. Study heterogeneity was assessed using I2% and 95 % prediction interval. Results A total of 22 studies (714 patients) were included. The pooled rate of technical success in EUS-PDD was 84.8 % (95 % CI 79.1–89.2). The pooled rate of successful PD drained by EUS-PDD was 77.5 % (95 % CI 63.1–87.4). The pooled rate of clinical success of EUS-PDD was 89.2 % (95 % CI 82.1–93.7). The pooled rate of all adverse events was 18.1 % (95 % CI 14.2–22.9). On sub-group analysis, the pooled technical success and clinical success of EUS-PDD from Japanese data were considerably superior (91.2 %, 83–95.6 & 92.5 %, 83.9–96.7, respectively). The pooled rate of post EUS-PDD acute pancreatitis was 6.6 % (95 % CI 4.5–9.4), bleeding was 4.1 % (95 % CI 2.7–6.2), perforation and/or pneumoperitoneum was 3.1 % (95 % CI 1.9–5), pancreatic leak and/or pancreatic fluid collection was 2.3 % (95 % CI 1.4–4), and infection was 2.8 % (95 % CI 1.7–4.6). Conclusion EUS-PDD demonstrates high technical success and clinical success rates with acceptable adverse events. Technical success was especially high for anastomotic strictures.


Endoscopy ◽  
2020 ◽  
Author(s):  
Takeshi Ogura ◽  
Nobu Nishioka ◽  
Saori Ueno ◽  
Tadahiro Yamada ◽  
Masanori Yamada ◽  
...  

Background With endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), guidewire manipulation might be a critically limiting step for nonexperts. However, the causes of difficult guidewire manipulation remain unclear. The aim of this study was to evaluate factors associated with successful guidewire manipulation. Methods This retrospective cohort study included consecutive patients who underwent EUS-HGS between October 2018 and October 2019. We measured scope angle between the long and needle axes of the echoendoscope using still fluoroscopic imaging immediately after puncturing the intrahepatic bile duct. Factors associated with successful guidewire insertion were assessed by multivariable analysis using logistic regression. Result The influence of the angle between the fine-needle aspiration (FNA) needle and echoendoscope on failed guidewire insertion was assessed using receiver operating characteristic (ROC) curves. Area under the ROC curve was 0.86 (95 % confidence interval [CI] 0.00 – 0.76), and an angle of 135° offered 88.0 % sensitivity and 82.9 % specificity for predicting successful guidewire insertion. According to multivariable analysis, only angle between the FNA needle and echoendoscope > 135° was independently associated with successful guidewire insertion (odd ratio 0.03, 95 %CI 0.01 – 0.14; P < 0.05), whereas sex, puncture site, and diameter of puncture site were not significant factors. After multivariable analysis, all variables were adjusted using age ≥ 70 or < 70 years, yielding the same results. Conclusion The angle between the FNA needle and echoendoscope might be associated with successful guidewire manipulation during EUS-HGS. Adjusting this angle to 135° before puncturing the intrahepatic bile duct might be helpful in achieving successful guidewire manipulation during EUS-HGS. 


1997 ◽  
Vol 85 (6) ◽  
pp. 1207-1213 ◽  
Author(s):  
Shobha Malviya ◽  
Terri Voepel-Lewis ◽  
Alan R. Tait

Sign in / Sign up

Export Citation Format

Share Document