scholarly journals Development and validation of a stability indicating RP-HPLC-DAD method for the determination of bromazepam

PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0244951
Author(s):  
Hany W. Darwish ◽  
Nesma A. Ali ◽  
Ibrahim A. Naguib ◽  
Mohamed R. El Ghobashy ◽  
Abdullah M. Al-Hossaini ◽  
...  

A reliable, selective and sensitive stability-indicating RP-HPLC assay was established for the quantitation of bromazepam (BMZ) and one of the degradant and stated potential impurities; 2-(2-amino-5-bromobenzoyl) pyridine (ABP). The assay was accomplished on a C18 column (250 mm × 4.6 mm i.d., 5 μm particle size), and utilizing methanol-water (70: 30, v/v) as the mobile phase, at a flow rate of 1.0 ml min-1. HPLC detection of elute was obtained by a photodiode array detector (DAD) which was set at 230 nm. ICH guidelines were adhered for validation of proposed method regarding specificity, sensitivity, precision, linearity, accuracy, system suitability and robustness. Calibration curves of BMZ and ABP were created in the range of 1–16 μg mL-1 with mean recovery percentage of 100.02 ± 1.245 and 99.74 ± 1.124, and detection limit of 0.20 μg mL-1 and 0.24 μg mL-1 respectively. BMZ stability was inspected under various ICH forced degradation conditions and it was found to be easily degraded in acidic and alkaline conditions. The results revealed the suitability of the described methodology for the quantitation of the impurity (ABP) in a BMZ pure sample. The determination of BMZ in pharmaceutical dosage forms was conducted with the described method and showed mean percentage recovery of 99.39 ± 1.401 and 98.72 ± 1.795 (n = 6), respectively. When comparing the described procedure to a reference HPLC method statistically, no significant differences between the two methods in regard to both accuracy and precision were found.

2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (04) ◽  
pp. 42-46
Author(s):  
Madhuri Manchala ◽  
◽  
Vijaya Sri Kanagala ◽  
Ganapath Vinay Jain

A simple, precise, accurate and robust RP-HPLC-PDA method was developed and validated for the determination of rilpivirine hydrochloride in tablet dosage forms. Reverse-phase chromatography was performed on a BDS hypersil (250 mm × 4.6 mm, 6 μm) column of Waters HPLC with Empower software and with a photodiode array detector. Methanol: acetonitrile: water 80:13.5:6.5 (v/v) was used as the mobile phase at a flow rate of 1 mL min-1 with PDA detection at 306 nm. Rilpivirine hydrochloride nanosuspension was prepared by using an ultrasonic homogenization method. Linearity was observed in the concentration range of 0.1–10 μg mL-1 with regression equation y = 508856X+46908 (R2 = 0.9998). The method was validated as per ICH guidelines. The RSD for intra-day (1.31- 0.67) and inter-day (1.69-1.59) precision was found to be less than 2%. The developed method is simple, precise and robust for the determination of rilpivirine hydrochloride and is successfully applied for the nanosuspension.


2013 ◽  
Vol 96 (3) ◽  
pp. 670-675 ◽  
Author(s):  
Balwinder Singh ◽  
Kousik Mandal ◽  
Sanjay K Sahoo ◽  
Urvashi Bhardwaj ◽  
Raminderjit Singh Battu

Abstract An easy and simple analytical method was standardized and validated for the estimation of residues of spirotetramat and its metabolite spirotetramat cis enol in various substrates: okra fruits, brinjal leaves and fruits, green chili, red chili, and soil. The samples were extracted with acetonitrile, diluted with brine solution, partitioned into dichloromethane, dried over anhydrous sodium sulfate, and cleaned up by treatment with activated charcoal powder. Final clear extracts were concentrated under vacuum and reconstituted with HPLC grade acetonitrile. Residues were estimated using HPLC with a photodiode array detector and a C18 column, and confirmed by HPTLC. Acetonitrile was used as the mobile phase at 0.4 mL/min. Both spirotetramat and spirotetramat cis enol presented distinct peak at retention times of 8.518 and 7.598 min, respectively. Consistent recoveries ranging from 82 to 97% for spirotetramat and spirotetramat cis enol were observed when samples were spiked at 1.00 to 0.03 mg/kg levels. The LOQ of the method was found to be 0.03 mg/kg. The analytical method was validated in terms of parameters, including selectivity, linearity, precision, and accuracy.


Sign in / Sign up

Export Citation Format

Share Document