scholarly journals Optimal Control Scheme for Non-Quadratic Performance Based on DHP Algorithm in Neural Networks

Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1877 ◽  
Author(s):  
Brage Rugstad Knudsen ◽  
Hanne Kauko ◽  
Trond Andresen

Industrial plants organized in clusters may improve their economics and energy efficiency by exchanging and utilizing surplus heat. However, integrating inherently dynamic processes and highly time-varying surplus-heat supplies and demands is challenging. To this end, a structured optimization and control framework may significantly improve inter-plant surplus-heat valorization. We present a Modelica-based systems model and optimal-control scheme for surplus-heat exchange in industrial clusters. An industry-cluster operator is assumed to coordinate and control the surplus-heat exchange infrastructure and responsible for handling the surplus heat and satisfy the sink plants’ heat demands. As a case study, we use an industry cluster consisting of two plants with surplus heat available and two plants with heat demand. The total surplus heat and heat demand are equal, but the availability and demand are highly asynchronous. By optimally utilizing demand predictions and a thermal energy storage (TES) unit, the operator is able to supply more than 98% of the deficit heat as surplus heat from the plants in the industry cluster, while only 77% in a corresponding case without TES. We argue that the proposed framework and case study illustrates a direction for increasing inter-plant surplus-heat utilization in industry clusters with reduced use of peak heating, often associated with high costs or emissions.


Author(s):  
Satoru Ito ◽  
Yuji Suzuki

Optimal control scheme for transient temperature profile inside electronic devices such as pulsed laser diode is developed based on the adjoint equation of one-dimensional heat conduction. Joule heating with a thin-film heater is employed as the control input in order to minimize temperature changes of a thin active layer embedded in a modeled laser diode. In numerical simulations assuming the light-emitting time period of 1 μs, temperature variation of the active layer is successfully suppressed by 80% with the heat input prior to the onset of the laser pulse. It is found that the Fourier number of the layer between the control heater and the active layer is the key parameter to minimize the temperature fluctuations. We also successfully demonstrate suppression of the temperature change in a MEMS-based experimental setup.


Sign in / Sign up

Export Citation Format

Share Document