Formulation, method development and validation of water soluble vitamins B1, B2 & B6 in bulk and tablet dosage form by HPTLC method

2018 ◽  
Vol 5 (1) ◽  
pp. 1-4
Author(s):  
Devi Velmurugan ◽  
Jambulingam Munusamy ◽  
Ananda Thangadurai Subramaniam ◽  
Anandkumar Karunakaran ◽  
Abdul Latiff MKM ◽  
...  

In the present study we are reporting  dissolution, method development and validation of water soluble vitamins B1, B2 & B6 in bulk and tablet dosage form by HPTLC method. The method is based on separation of the three vitamins using HPTLC. Thin layer chromatographic plates coated with silica gel 60F254 as the stationary phase and acetonitrile:water (6:4 v/v) as mobile phase. The chromatographic analysis was carried out in the reflectance and absorbance mode at 280 nm. The method was validated with respect to linearity, accuracy and precision, limit of detection and limit of quantitation. It was then applied for analysis of vitamins B1, B2 & B6 in combined tablet dosage form. The above method developed was reproducible with good resolution and the results of analysis have been validated with correlation coefficient of 0.9990

2019 ◽  
Vol 15 (3) ◽  
pp. 243-250 ◽  
Author(s):  
Surendra Agrawal ◽  
Pravina Gurjar ◽  
Bhavik Katheriya

Introduction: Trimetazidine and Metoprolol combination is more effective in the treatment of cardiac disorders as compared to single drug therapy.Background: Materials and Methods: A rapid, simple, and sensitive HPTLC method was developed for the simultaneous determination of Trimetazidine and metoprolol from its tablet dosage form and validated. In HPTLC method, standard and sample solutions of Trimetazidine hydrochloride and metoprolol succinate were applied on pre-coated silica gel G 60 F254 TLC plate, and developed by using mobile phase, n-butanol :water: methanol: ammonia as solvent (8.5:0.1:0.1: 0.85, v/v). The drugs on plate were scanned at 213 nm. The method produced compact and well-resolved bands at Rf of 0.32 ± 0.02 and 0.66 ± 0.02 for Trimetazidine Hydrochloride and Metoprolol succinate respectively. The range for linearity was observed as 500-2500 ng band-1 for Trimetazidine hydrochloride and 500-2500 ng band-1 for metoprolol succinate and correlation coefficient were 0.9991 and 0.9997 respectively. Conclusion: The developed method was validated according to the ICH guidelines for precision, accuracy, Limit of detection, Limit of quantitation, specificity and robustness. The method was checked for suitability in determination of Trimetazidine hydrochloride and Metoprolol succinate in their tablet dosage form. The assay result was found to be 99.64 % ± 0.45 and 99.94 % ± 0.53 of percentage label claim for Trimetazidine hydrochloride and Metoprolol succinate respectively.


Author(s):  
Pushpa Latha E. ◽  
Sailaja B.

Analytical UV derivative spectrophotometric method was developed and validated to quantify Rizatriptan Benzoate in pure drug and tablet dosage form. Based on the spectrophotometric characteristics of Rizatriptan Benzoate, a signal of zero (225nm), first (216nm), second (237nm), third (233nm), fourth (231nm) order derivative spectra were found to be adequate for quantification. The methods obeyed Beer's law in the concentration range of (0.1-360µg/ml) with square correlation coefficient (r2) of 0.999. The mean percentage recovery was found to be 100.01 ± 0.075. As per ICH guidelines the results of the analysis were validated in terms of linearity, precision, accuracy, limit of detection and limit of quantification, and were found to be satisfactory.


Sign in / Sign up

Export Citation Format

Share Document