scholarly journals Is there a role for prophylactic antibiotics in the prevention of urinary tract infections following Foley catheter removal in patients having abdominal surgery?

2011 ◽  
Vol 54 (3) ◽  
pp. 206-208 ◽  
Author(s):  
C. Suzanne Cutter
2012 ◽  
Vol 40 (5) ◽  
pp. e92-e93 ◽  
Author(s):  
Lynn Roser ◽  
Terry Altpeter ◽  
Dee Anderson ◽  
Mark Dougherty ◽  
Jo Ellen Walton ◽  
...  

Author(s):  
Ylva Kai-Larsen ◽  
Stefan Grass ◽  
Bhaumik Mody ◽  
Swati Upadhyay ◽  
Hargovind L. Trivedi ◽  
...  

Abstract Background Catheter-associated urinary tract infections (CAUTI) are among the most frequent healthcare-associated infections in the world. They are associated with increased mortality, prolonged hospital stay and increased healthcare costs. The objective of this study was to evaluate the efficacy of the noble metal alloy (NMA) coated BIP Foley Catheter in preventing the incidence of symptomatic CAUTI in a large cohort of patients in India. Methods This multi-center, prospective study included 1000 adult patients admitted to six hospitals across India for urology, surgery and ICU requiring urethral catheterization and admission for ≥ 48 h. Patients were allocated to the NMA-coated BIP Foley Catheter group or a non-coated control catheter group, with a randomization ratio of 3:1. CAUTI surveillance was conducted at study entry, upon catheter removal, and 2 days after catheter removal. For statistical analysis, categorical data (e.g. gender) were compared using the chi-square or Fischer test, and numerical data were compared using the two-sample t-test. Associations were evaluated using logistic regression. Results and conclusions The incidence of symptomatic CAUTI was reduced by 69% in the BIP Foley Catheter group compared to the control group (6.5 vs 20.8 CAUTI/1000 catheter days), with an incidence rate ratio of 0.31 (95% confidence interval: 0.21–0.46; p < 0.001). A reduction in the cumulative CAUTI incidence was evident in the BIP Foley Catheter group within 3 days after catheterization; this reduction was maintained up to ~ 30 days, and the largest reductions were seen between 3 and 11 days. There were no serious adverse events related to either catheter, and the percentage of patients with ≥ 1 adverse event was significantly lower in the NMA-coated BIP Foley Catheter group than in the control group (21.6% vs. 48.4%; p = 0.001). In conclusion, the NMA-coated BIP Foley Catheter was effective in reducing CAUTI and was well tolerated, with a lower incidence of adverse events compared to the uncoated catheter. Trial registration This study was registered prospectively (28 September 2015) in the Clinical Trials Registry of India (trial number CTRI/2015/09/006220; http://ctri.nic.in/Clinicaltrials/showallp.php?mid1=12631&EncHid=&userName=bactiguard).


2006 ◽  
Vol 17 (3) ◽  
pp. 272-283
Author(s):  
Laura Reilly ◽  
Patty Sullivan ◽  
Sharon Ninni ◽  
Denise Fochesto ◽  
Karen Williams ◽  
...  

The prolonged use of indwelling urinary catheters can lead to many complications, the most prevalent being urinary tract infections. These hospital-acquired infections can increase hospital costs, length of stay, and mortality rates. Evidence-based guidelines for the prevention of urinary tract infections are compared and discussed. Minimizing indwelling urinary catheter use is well-recognized in the literature to reduce the risk of these infections. To decrease the incidence of catheter-associated urinary tract infections, the staff of a 22-bed, mixed medical, surgical, and trauma intensive care unit focused on reducing the number of foley catheter device days. A multidisciplinary team was convened to create an evidence-based plan. Staff nurses were engaged in the development and implementation of the plan. Criteria-based foley catheter guidelines, a decision-making algorithm, and a daily checklist were implemented that led to a significant reduction in foley catheter device days and a decrease in catheter-associated urinary tract infections.


Sign in / Sign up

Export Citation Format

Share Document