Reference ranges of the Sebia free light chain ratio in patients with chronic kidney disease

2018 ◽  
Vol 56 (9) ◽  
pp. e232-e234 ◽  
Author(s):  
Laurence Lutteri ◽  
Joannes F.M. Jacobs
2014 ◽  
Vol 89 (5) ◽  
pp. 615-622 ◽  
Author(s):  
Colin A. Hutchison ◽  
Anne Burmeister ◽  
Stephen J. Harding ◽  
Kolitha Basnayake ◽  
Hannah Church ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (10) ◽  
pp. e0141404
Author(s):  
Lakhvir K. Assi ◽  
Natasha McIntyre ◽  
Simon Fraser ◽  
Scott Harris ◽  
Colin A. Hutchison ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (7) ◽  
pp. e0129980 ◽  
Author(s):  
Lakhvir K. Assi ◽  
Natasha McIntyre ◽  
Simon Fraser ◽  
Scott Harris ◽  
Colin A. Hutchison ◽  
...  

Toxins ◽  
2013 ◽  
Vol 5 (11) ◽  
pp. 2058-2073 ◽  
Author(s):  
Lucie Desjardins ◽  
Sophie Liabeuf ◽  
Aurélie Lenglet ◽  
Horst-Dieter Lemke ◽  
Raymond Vanholder ◽  
...  

2018 ◽  
Vol 56 (2) ◽  
pp. 312-322 ◽  
Author(s):  
Joannes F.M. Jacobs ◽  
Corrie M. de Kat Angelino ◽  
Huberdina M.L.M. Brouwers ◽  
Sandra A. Croockewit ◽  
Irma Joosten ◽  
...  

Abstract Background: Serum free light chain (sFLC) measurements are increasingly important in the context of screening for monoclonal gammopathies, prognostic stratification, and monitoring of therapy responses. At the same time, analytical limitations have been reported with the currently available nephelometric and turbidimetric sFLC assays. We have evaluated a new quantitative sFLC ELISA for its suitability in routine clinical use. Methods: Reference ranges of the Sebia FLC assay were calculated from 208 controls. Assay interference, reproducibility, lot-to-lot variability, and linearity were assessed. Method comparison to the Freelite assay (Binding Site) was conducted by retrospective analysis of 501 patient sera. Results: Reference ranges of the Sebia κ/λFLC-ratio were 0.37–1.44. We observed good sensitivity (1.5 mg/L) and linearity in both polyclonal and monoclonal sFLC samples and never experienced antigen excess. Sebia FLC reproducibility varied between 6.7% and 8.1% with good lot-to-lot consistency. Method comparison with Freelite showed the following correlations: κFLC R=0.94, λFLC R=0.92 and κ/λFLC-ratio R=0.96. The clinical concordance of the κ/λFLC-ratio of both methods was 94%. Significant quantitative differences were observed between both methods, mainly in sera with high FLC concentrations. The Sebia monoclonal FLC concentrations were coherent with those obtained by serum protein electrophoresis (SPE). Freelite monoclonal FLC concentrations were consistently higher, with a mean 12-fold overestimation compared to SPE. Conclusions: The Sebia FLC assay provides a novel platform for sensitive and accurate sFLC measurements. The Sebia FLC showed good clinical concordance with Freelite. Further studies are warranted to confirm the clinical value of this assay.


2019 ◽  
Vol 23 (6) ◽  
pp. 763-772
Author(s):  
Olga Kukuy ◽  
Batia Kaplan ◽  
Sizilia Golderman ◽  
Alexander Volkov ◽  
Adrian Duek ◽  
...  

Author(s):  
Lauren Campbell ◽  
Dawn Simpson ◽  
Adrian Shields ◽  
Berne Ferry ◽  
Karthik Ramasamy ◽  
...  

Background The measurement of monoclonal free light chains is being increasingly utilized since the introduction of serum-based assays. It is important for laboratories to determine their own reference ranges in order to reflect the local population. The aim of this study was to determine if age-adjusted reference ranges for serum free light chains would have implications for demand management of further laboratory investigations including immunofixation. Methods After certain exclusions, 4293 samples from individuals seen in primary care across Oxfordshire between 2014 and 2016 were identified for analysis of patient characteristics, serum free light chain results and estimated glomerular filtration rate. Results We found age to be an independent variable when considering serum free light chain concentrations, ratio and estimated glomerular filtration rate. The reference ranges derived from our data differ markedly from the original Binding Site ranges. When the age-specific ranges are retrospectively applied to our population, there is a 38% decrease in follow-up testing with no loss of specificity. Conclusion We feel confident implementing new age-specific serum free light chain reference ranges in our laboratory. We have developed a simple algorithm for evaluating serum free light chains based on age and estimated glomerular filtration rate. We encourage laboratories to establish their own local reference ranges using large cohorts and their chosen serum free light chain assay platform.


2009 ◽  
Vol 5 (11) ◽  
pp. 621-628 ◽  
Author(s):  
Colin A. Hutchison ◽  
Kolitha Basnayake ◽  
Paul Cockwell

Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 5883-5883 ◽  
Author(s):  
Deborah Kuhn ◽  
Ping Wang ◽  
Irene Shu ◽  
Jie Xuan ◽  
Zheng Cao ◽  
...  

Abstract Background: Post-transplant lymphoproliferative disorder (PTLD) is primarily diagnosed histologically using tissue biopsy. Free light chain (FLC) assay and serum protein electrophoresis (SPE) have both been studied as tools to screen and monitor PTLD. However, limited data are available to compare these two assays in a well characterized patient population. It is also not clear what reference ranges should be adopted for the FLC assay in a post-transplant population. Method: Blood samples from 169 patients receiving a variety of solid organ transplants were analyzed for FLCs and screened for gammopathies by SPE/IFE. Results: Compared with non-PTLD patients, PTLD patients had higher mean, median and upper 95 percentile range of both κ and λ FLCs (p ranging from 0.0002 to 0.024). The mean, median and 95 percentile range of κ:λ ratio were similar between the two groups. PTLD patients were more likely to have polyclonal or monoclonal FLC elevations (p = 0.04). They also showed a higher frequency of gammopathy abnormalities (p = 0.0052). Nonetheless, neither FLC assay nor SPE demonstrated a clear association with the timing of PTLD diagnosis. FLC concentrations in non-PTLD recipients were higher than those in the general healthy population (95 percentile range: κ, 0.60-8.33 mg/dL vs. 0.33-1.94 mg/dL; λ, 0.77-7.08 mg/dL vs. 0.571-2.63 mg/dL) but the κ:λ ratio was similar to that of the healthy group (0.26-1.65). Conclusions: Our results suggested that elevated FLC concentrations and gammopathy abnormalities were both associated with PTLD. Therefore, FLC assay and SPE should be used conjunctively for screening PTLD among solid organ transplant recipients. For this application, the data showed that a higher upper limit of κ and λ FLC levels and normal κ:λ ratio should be used as diagnostic reference ranges. Additionally, neither method was clearly associated with the timing of PTLD diagnosis, indicating that they may be unsuitable for monitoring PTLD in the post-transplant population. Table 1. Longitudinal measurements of serum/plasma free light chains and SPE/IFE in eight PTLD cases. Type of transplant and type of PTLD Samples Days from PTLD diagnosisa κ FLC, mg/dL λ FLC, mg/dL κ /λ SPE/IFE Liver transplant, B-cell PTLD 1.1 1.2 – 616 2.33b 1.82 4.96 6.01 0.47 0.303 no band –c Liver transplant, B-cell PTLD 2.1 2.2 2.3 2.4 2.5 -145* -126 84 141 428 0.338 0.79 0.335 0.476 2.53 0.62 1.02 1.06 1.15 1.98 0.545 0.775 0.316 0.414 1.28 no band no band 1 IgG ©µ, 1 IgG λ 1 IgG ©µ, 1 IgG λ no band Liver transplant, polymorphic hyperplasia 3.1 3.2 -77 208 4.19 7.18 5.9 3.38 0.71 2.12 2 IgG ©µ, 2 λ FLC– Liver transplant, B-cell PTLD 4.1 4.2 4.3 61 272 537 4.64 3.25 7.1 11.1 6.65 10.96 0.418 0.489 0.648 no band no band no band Liver transplant, B-cell PTLD 5.1 5.2 5.3 5.4 5.5 9 12 393 429 476 305.5 957 0.721 1.01 1.24 74.25 192 1.67 1.72 2.56 4.11 4.98 0.432 0.587 0.484 1 IgG ©µ, 1 λ FLC 2 IgM ©µ no band no band no band Liver transplant, B-cell PTLD 6.1 6.2 6.3 6.4 62 153 174 188 3.16 5.58 3.97 2.14 2.92 3.91 3.81 3.37 1.08 1.43 1.04 0.635 – 1 IgG ©µ 1 IgG ©µ 1 IgG ©µ Kidney transplant, PTLD 7.1 7.2 15 30 1.4 1.68 1.58 2.06 0.89 0.82 no band no band Lung transplant, Non-Hodgkin lymphoma 8.1 -60 4.28 4.58 0.94 no band a Positive values indicate time points before PTLD diagnosis, while negative values indicate time points after PTLD diagnosis. b Numbers in bold format indicates values above ULN. c SPE/IFE results not available due to insufficient sample volume. Disclosures Kuhn: The Binding Site, Inc: Employment.


Sign in / Sign up

Export Citation Format

Share Document