Test Method for the Determination of Impurities in Plutonium Metal: Acid Digestion and Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) Analysis

2006 ◽  
Author(s):  
2019 ◽  
Vol 85 (4) ◽  
pp. 110-113
Author(s):  
Olexandr Ponomarenko ◽  
Anatolyi Samchuk ◽  
Kateryna Vovk ◽  
Igor Shvaika ◽  
Ganna Grodzinskaya

The analytical technologies of sample preparation of rocks and mushrooms using the microwave field for the determination of germanium by the method of mass spectrometry with inductively coupled plasma (ICP-MS analysis) have been developed. Germanium is a rare element. Germanium is homology of silicon and carbon. To date, the definition of low content of germanium in geological objects is a rather complex analytical task, which requires its concentration - extraction, co-precipitation, ion exchange. At present, the harmonious combination of the method of natural objects decomposition in the microwave field and germanium determination using ICP-MS analysis is particularly promising. Sample preparation of silicate rocks for ICP-MS determination of germanium was carried out by decomposition in a mixture of hydrofluoric, phosphate and nitric acids (5: 5: 2) in a microwave oven program at 240°C for 30 min. Sample preparation of mushrooms for ICP-MS germanium determination was carried out according to the following scheme. Initially, the dried sample was sealed in the presence of CaO, after dissolving it in a mixture of HNO3+HF+H3PO4 (6:6:1). Ge solution was extracted by Nazarenko V.A. extraction method. The developed analytical schemes have made it possible to significantly reduce the duration and labor intensity of sample preparation. The obtained solutions were analyzed using an inductively coupled plasma mass spectrometer. The developed method for determining germanium by ICP-MS analysis has been successfully tested on standard rock samples. The obtained results are in accordance with the accepted attribute, the relative standard deviation Sr ranges from 0.7-0.9. The data on the content and distribution of germanium in the Boletales fungi are obtained. They indicate wild mushrooms contain high levels of germanium, especially Boletus and Mushroom biospores. These studies are necessary because the essential properties of germanium and its compounds attract special attention of scientists today. Complementary Ge compounds which have hypotensive, bactericidal, antiviral and antitumor effects have already been synthesized.


2014 ◽  
Vol 29 (9) ◽  
pp. 1720-1725 ◽  
Author(s):  
Krishnan Chandrasekaran ◽  
Dheram Karunasagar

Matrix precipitation for the sensitive determination of impurities in the Pb–Bi eutectic system by ICP-MS.


1994 ◽  
Vol 77 (4) ◽  
pp. 1004-1023 ◽  
Author(s):  
J E Longbottom ◽  
T D Martin ◽  
K W Edgell ◽  
S E Long ◽  
M R Plantz ◽  
...  

Abstract A joint U.S. Environmental Protection Agency (U.S. EPA)—AOAC interlaboratory method validation study was conducted on U.S. EPA method 200.8, Determination of Trace Elements in Waters and Wastes by Inductively Coupled Plasma–Mass Spectrometry. The purpose of the study was to determine and compare the mean recovery and precision of the inductively coupled plasma–mass spectrometry (ICP–MS) analyses for 20 trace elements in reagent water, drinking water, and groundwater. The formal study was based on Youden’s nonreplicate plan for collaborative tests of analytical methods. The test waters were spiked with the 20 trace elements at 6 concentration levels in the 0.8–200 μg/L range, prepared as 3 Youden pairs. Thirteen collaborators spiked 100 mL aliquots of the test waters, acidified them with 1 mL concentrated HNO3 and 0.5 mL concentrated HCl, reduced the volume to 20 mL by heating in an open beaker at 85°C, refluxed them for 30 min at 95°C, and diluted them to 50 mL. After centrifuging or settling the samples, a 20 mL portion of the supernatant was diluted to 50 mL and analyzed by ICP–MS. Related experiments evaluated the method performance in wastewater and wastewater digestate at a single concentration pair, and an alternative nitric acid digestion procedure. Mean recoveries for reagent water, drinking water, and groundwater were generally 95–105% with between-laboratory relative standard deviations about 4–8%. The method also worked well with wastewaters and digestate, with between-laboratory relative standard deviations averaging 8% and recoveries averaging 100%. Recoveries of silver, however, were low in all matrixes at concentrations over 100 μg/L. The nitric acid digestion procedure was comparable in accuracy and precision to the mixed-acid digestion in U.S. EPA method 200.8. The method was adopted first action by AOAC INTERNATIONAL.


Sign in / Sign up

Export Citation Format

Share Document