electrothermal vaporization
Recently Published Documents


TOTAL DOCUMENTS

530
(FIVE YEARS 23)

H-INDEX

44
(FIVE YEARS 3)

Molecules ◽  
2021 ◽  
Vol 26 (9) ◽  
pp. 2642
Author(s):  
Simion Bogdan Angyus ◽  
Erika Levei ◽  
Dorin Petreus ◽  
Radu Etz ◽  
Eniko Covaci ◽  
...  

The simultaneous determination of chemical vapor-generating elements involving derivatization is difficult even by inductively coupled plasma optical emission spectrometry or mass spectrometry. This study proposes a new direct liquid microsampling method for the simultaneous determination of As, Bi, Se, Te, Hg, Pb, and Sn, using a fully miniaturized set-up based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry. The method is cost-effective, free from non-spectral interference, and easy to run by avoiding derivatization. The method involves the vaporization of analytes from the 10 µL sample and recording of episodic spectra generated in low-power (15 W) and low-Ar consumption (150 mL min−1) plasma microtorch interfaced with low-resolution microspectrometers. Selective vaporization at 1300 °C ensured the avoidance of non-spectral effects and allowed the use of external calibration. Several spectral lines for each element even in the range 180–210 nm could be selected. Generally, this spectral range is examined with large-scale instrumentation. Even in the absence of derivatization, the obtained detection limits were low (0.02–0.75 mg kg−1) and allowed analysis of environmental samples, such as cave and river sediments. The recovery was in the range of 86–116%, and the accuracy was better than 10%. The method is of general interest and could be implemented on any miniaturized or classical laboratory spectrometric instrumentation.


Author(s):  
Peizhe Xing ◽  
Xue Li ◽  
Li Feng ◽  
Xuefei Mao

In this work, a novel and green solid sampling method of Cd in grain samples was established based on electrothermal vaporization atomic absorption spectrometry (ETV-AAS).


Author(s):  
Patricia Maung ◽  
Diane Beauchemin

The effect on the detection of fluorine (F) in solid samples of adding H2 to the carrier gas in electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry...


Author(s):  
Aleksey V. Kuptsov ◽  
Nickolay S. Medvedev ◽  
Olga V. Lundovskaya ◽  
Anatoly I. Saprykin ◽  
Vladimir A. Labusov

The combination of two-jet arc plasma optical emission spectrometry (TJP-OES) and electrothermal vaporization (ETV) for sample introduction is proposed for the first time.


Sign in / Sign up

Export Citation Format

Share Document